Primary Contents

IAグローバル検索結果

国/地域選択

IAグローバル検索
結果 4641 - 466038071
E5AC-CQ4DSM-008 | OMRON Industrial Automation

...C Allowable voltage variable range 85 to 110% of the power supply voltage Power consumption 3.4 W max. (at 24 VDC) 5.6 VA max. (at 24 VAC) Input Number of input points 1 point Temperature inp...

https://www.ia.omron.com/product/item/2810/

E5AC-CQ4DSM-009 | OMRON Industrial Automation

...C Allowable voltage variable range 85 to 110% of the power supply voltage Power consumption 3.4 W max. (at 24 VDC) 5.6 VA max. (at 24 VAC) Input Number of input points 1 point Temperature inp...

https://www.ia.omron.com/product/item/2811/

E5AC-CQ4DSM-010 | OMRON Industrial Automation

...C Allowable voltage variable range 85 to 110% of the power supply voltage Power consumption 3.4 W max. (at 24 VDC) 5.6 VA max. (at 24 VAC) Input Number of input points 1 point Temperature inp...

https://www.ia.omron.com/product/item/2812/

E5AC-CQ4DSM-011 | OMRON Industrial Automation

...C Allowable voltage variable range 85 to 110% of the power supply voltage Power consumption 3.4 W max. (at 24 VDC) 5.6 VA max. (at 24 VAC) Input Number of input points 1 point Temperature inp...

https://www.ia.omron.com/product/item/2813/

E5AC-CQ4DSM-012 | OMRON Industrial Automation

...C Allowable voltage variable range 85 to 110% of the power supply voltage Power consumption 3.4 W max. (at 24 VDC) 5.6 VA max. (at 24 VAC) Input Number of input points 1 point Temperature inp...

https://www.ia.omron.com/product/item/2814/

E5AC-CX2ASM-000 | OMRON Industrial Automation

... Number of input points 1 point Temperature input Thermocouple: K, J, T, E, L, U, N, R, S, B, C/W, PLII Platinum resistance thermometer: Pt100, JPt100 Infrared Thermosensor: 10 to 70 ℃, 60 to...

https://www.ia.omron.com/product/item/2815/

E5AC-CX2ASM-004 | OMRON Industrial Automation

... Number of input points 1 point Temperature input Thermocouple: K, J, T, E, L, U, N, R, S, B, C/W, PLII Platinum resistance thermometer: Pt100, JPt100 Infrared Thermosensor: 10 to 70 ℃, 60 to...

https://www.ia.omron.com/product/item/2816/

E5AC-CX2ASM-005 | OMRON Industrial Automation

... Number of input points 1 point Temperature input Thermocouple: K, J, T, E, L, U, N, R, S, B, C/W, PLII Platinum resistance thermometer: Pt100, JPt100 Infrared Thermosensor: 10 to 70 ℃, 60 to...

https://www.ia.omron.com/product/item/2817/

E5AC-CX2ASM-013 | OMRON Industrial Automation

... Number of input points 1 point Temperature input Thermocouple: K, J, T, E, L, U, N, R, S, B, C/W, PLII Platinum resistance thermometer: Pt100, JPt100 Infrared Thermosensor: 10 to 70 ℃, 60 to...

https://www.ia.omron.com/product/item/2818/

E5AC-CX2ASM-014 | OMRON Industrial Automation

... Number of input points 1 point Temperature input Thermocouple: K, J, T, E, L, U, N, R, S, B, C/W, PLII Platinum resistance thermometer: Pt100, JPt100 Infrared Thermosensor: 10 to 70 ℃, 60 to...

https://www.ia.omron.com/product/item/2819/

E5AC-CX2DSM-000 | OMRON Industrial Automation

...C Allowable voltage variable range 85 to 110% of the power supply voltage Power consumption 2.4 W max. (at 24 VDC) 4.2 VA max. (at 24 VAC) Input Number of input points 1 point Temperature inp...

https://www.ia.omron.com/product/item/2820/

E5AC-CX2DSM-004 | OMRON Industrial Automation

...C Allowable voltage variable range 85 to 110% of the power supply voltage Power consumption 3.4 W max. (at 24 VDC) 5.6 VA max. (at 24 VAC) Input Number of input points 1 point Temperature inp...

https://www.ia.omron.com/product/item/2821/

E5AC-CX2DSM-005 | OMRON Industrial Automation

...C Allowable voltage variable range 85 to 110% of the power supply voltage Power consumption 3.4 W max. (at 24 VDC) 5.6 VA max. (at 24 VAC) Input Number of input points 1 point Temperature inp...

https://www.ia.omron.com/product/item/2822/

E5AC-CX2DSM-013 | OMRON Industrial Automation

...C Allowable voltage variable range 85 to 110% of the power supply voltage Power consumption 3.4 W max. (at 24 VDC) 5.6 VA max. (at 24 VAC) Input Number of input points 1 point Temperature inp...

https://www.ia.omron.com/product/item/2823/

E5AC-CX2DSM-014 | OMRON Industrial Automation

...C Allowable voltage variable range 85 to 110% of the power supply voltage Power consumption 3.4 W max. (at 24 VDC) 5.6 VA max. (at 24 VAC) Input Number of input points 1 point Temperature inp...

https://www.ia.omron.com/product/item/2824/

E5AC-CX4ASM-000 | OMRON Industrial Automation

... Number of input points 1 point Temperature input Thermocouple: K, J, T, E, L, U, N, R, S, B, C/W, PLII Platinum resistance thermometer: Pt100, JPt100 Infrared Thermosensor: 10 to 70 ℃, 60 to...

https://www.ia.omron.com/product/item/2825/

E5AC-CX4ASM-004 | OMRON Industrial Automation

... Number of input points 1 point Temperature input Thermocouple: K, J, T, E, L, U, N, R, S, B, C/W, PLII Platinum resistance thermometer: Pt100, JPt100 Infrared Thermosensor: 10 to 70 ℃, 60 to...

https://www.ia.omron.com/product/item/2826/

E5AC-CX4ASM-005 | OMRON Industrial Automation

... Number of input points 1 point Temperature input Thermocouple: K, J, T, E, L, U, N, R, S, B, C/W, PLII Platinum resistance thermometer: Pt100, JPt100 Infrared Thermosensor: 10 to 70 ℃, 60 to...

https://www.ia.omron.com/product/item/2827/

E5AC-CX4ASM-013 | OMRON Industrial Automation

... Number of input points 1 point Temperature input Thermocouple: K, J, T, E, L, U, N, R, S, B, C/W, PLII Platinum resistance thermometer: Pt100, JPt100 Infrared Thermosensor: 10 to 70 ℃, 60 to...

https://www.ia.omron.com/product/item/2828/

E5AC-CX4ASM-014 | OMRON Industrial Automation

... Number of input points 1 point Temperature input Thermocouple: K, J, T, E, L, U, N, R, S, B, C/W, PLII Platinum resistance thermometer: Pt100, JPt100 Infrared Thermosensor: 10 to 70 ℃, 60 to...

https://www.ia.omron.com/product/item/2829/

結果 4641 - 466038071

国/地域選択

Related Contents