Primary Contents

IAグローバル検索結果

国/地域選択

IAグローバル検索
結果 481 - 5002231
PDF[W566-E1-06] NX-TS[][][][]/HB[][][][] Analog I/O U...

...es and Functions Terminal Blocks There are two models of screwless clamping terminal blocks: NX-TB2 and NX-TB1. Each model has three types of terminal blocks: 8-terminal type, ...

https://www.fa.omron.co.jp/data_pdf/mnu/w566-e1-06_nx-ts_hb.pdf

PDFMachine Automation Controller NX-series

...g terminal block. Refer to Securing Wires on page 4-18 for how to secure wires. *2. With the NX-TB£££1 Terminal Block, use twisted wires to connect the ground terminal. Do not use a solid wir...

https://www.fa.omron.co.jp/data_pdf/mnu/w567-e1-08_nx-ilm.pdf

PDF[W568-E2-05] NY532-1[]00/5400, NY512-1[]00 Industr...

... 7: 256 GB CFast MLC 8: 32 GB, SSD SLC 9: 64 GB, SSD SLC C: 320 GB, HDD K: 128 GB, SSD MLC P: 1 TB, SSD 3D TLC 16 Optional interface 0: None 1: RS-232C 2: DVI-D 6: NY Monitor Link 17 Logo 0: ...

https://www.fa.omron.co.jp/data_pdf/mnu/w568-e2-05_ny532_ny512.pdf

PDF[W594-E1-08] NX701-Z[][][], NY532-Z[][][], NY512-Z...

...orage temperature -55 to 95°C*3 Storage humidity 10% to 95%RH (with no condensation)*3 Life 374 TB *1. *2. *3. A-4 2500 TB A dedicated storage device to be used as the main storage o...

https://www.fa.omron.co.jp/data_pdf/mnu/w594-e1-08_nx701-z_ny5_2-z.pdf

PDF[W616-E2-07] NYB[][]-[][][]/NYP[][]-[][][] Industr...

...MLC 7: 256 GB, CFast MLC 8: 32 GB, SSD SLC 9: 64 GB, SSD SLC C: 320 GB, HDD D: 500 GB, HDD E: 1 TB, HDD F: 128 GB, SSD 3D TLC G: 256 GB, SSD 3D TLC H: 512 GB, SSD 3D TLC K: 128 GB, SSD MLC L:...

https://www.fa.omron.co.jp/data_pdf/mnu/w616-e2-07_nyb_nyp.pdf

PDF[Z439-E-03(84-9000362-03-E)] V410-H/V450-H Handhel...

...ted Bleach • Carbolic acid • Compounds of amines or ammonia • Ethanolamine • Ethers • Ketones • TB-lysoform • Toluene • Trichloroethylene Tolerable Industrial Fluids and Chemicals Not all flu...

https://www.fa.omron.co.jp/data_pdf/mnu/z439-e-03_v410-h_v450-h.pdf

PDF队顔⯥陴ⱷ䑒ꠢ陸䡘⺚粠珇┕氳嫱䙬◄걸ն ������品��������

...的数据。 CAD数据可从网站https://www.ecb.omron.com.cn/下载。 CADᮦᦤ 1 1.5 R1 1 1 1 1 GND VCC SDA SCL SM04B-GHS-TB(JST) 8.25 4.05 (0.85) 4.4 (3.75) 11.5 5 11 14 18 ij8.3 1 3.4 2-ij1 2.5 2.5 R1 R1 ...

https://www.fa.omron.com.cn/data_pdf/cat/cdsc-cn1-012h.pdf

PDFN-Smart放大器 如果使用多点传感器 利用网络将更加方便,

...见“便利设定” 想设定输出的定时器时间时当想变更光量及响应时间时 A (100~9999 1刻度、初始值9999) 参见“便利设定” Tb Ta Tb 遮光时 ON OFF ON OFF Ta 遮光时ON 入光时ON 遮光时ON 在[设定模式...

https://www.fa.omron.com.cn/data_pdf/cat/e32_e3nx-fa_e3nw_ca_c_16_8.pdf

PDFBest Selection Start with Smart!

... (a) (b) (c) (d) (a) (d) (b) (c) (a) (b) (c) SHS2 Super High-speed Mode (e) (d) (a) (b) (c) (d) Tb Ta Tb No incident light ON OFF ON OFF Ta Setting ON or OFF Incident Level Adjustmen...

https://www.fa.omron.com.cn/data_pdf/cat/e32_e3nx-fa_e3nw_e418-e1_20_5_csm1002396.pdf

PDFE3C-LDA E3C ܝ⬉Ӵᛳ఼ Ӵᛳ఼ᣛफ ܝ⬉Ӵᛳ఼ ҟ㒡

...导线长度在受光侧(白线)为20mm以下,投光侧(红线)为 50mm以下。 ᡩܝ఼ফܝ఼ ᆚᇕ㒓㑶 ⱑ ᥻ࠊ䕧ܹ -˄⊼˅ ᮴᥹⚍䕧ߎ + - + Tb Ta Tc AC100̚240V ᆚᇕ㒓 2 1 11 10 5678 9 3 4 ൟোE3C-A/C ᡩgফܝ఼ ⱑ 㑶 ൟোE3C-A/C ᥻ࠊ䕧ܹ -˄⊼˅...

https://www.fa.omron.com.cn/data_pdf/cat/e3c_ds_c_1_1.pdf

PDFColor Mark Sensors E3S-DC/E3NX-CA Series

...dent light ON OFF ON OFF L-ON D-ON T T Incident light No incident light ON OFF ON OFF L-ON D-ON Tb Ta Tb Ta ch1 ch2 ON OFF ON OFF ON OFF ON OFF OUT (OR) OUT (AND) E3NX-CA 29 Nomencla...

https://www.fa.omron.com.cn/data_pdf/cat/e3s-dc_e3nx-ca_y216-e1_1_9_csm1052116.pdf

PDFIoT Flow Sensors/IoT Pressure Sensors

...lement Ta, and then the flow rate based on the pipe diameter. The temperature measuring element Tb directly measures fluid temperature. Time Ta-Tb Temperature dierence Temperature me...

https://www.fa.omron.com.cn/data_pdf/cat/e8fc_e8pc_e472-e1_4_3_csm1065029.pdf

PDFℓ/minºC MPaºC IoT液体流量传感器/IoT液体压力传感器

...Ta一定时间,测量其以多快的速度散热,从而检测流体的流速。 据此将配管直径换算为流量。 流量温度用温度计测元件Tb直接测量液体温度。 温度温度计测元件 Ta:向底面的温度计测元件Ta施加脉冲电流 Ta ...

https://www.fa.omron.com.cn/data_pdf/cat/e8fc_e8pc_scea-cn5-192_1_9.pdf

PDF䗮䖛䴭ℶ੠Ԣ䗳ⲥ᥻ᦤ催ᬜ⥛ CSM_G9SX-SM_-LM_CA_C_5_1

...䗮䖛䴭ℶ੠Ԣ䗳ⲥ᥻ᦤ催ᬜ⥛ CSM_G9SX-SM_-LM_CA_C_5_1 2 3 OFFᓊ䖳ᅮᯊ఼ Ꮖ㾷䫕䴭ℶⲥ᥻ৃҹޣᇥᎹ԰ᳳ䯈ⱘ乱໪ㄝ׭ᯊ䯈䯂乬㾷އᮍḜ Tᖙ乏ᣝҹϟᮍᓣ䆒㕂˖T > tB > tA tA tB 㾷䫕㾷䫕 ⼎՟˖ ᔧᎹӊব࣪ᯊˈذᴎᯊ䯈гӮবDŽ ᔧ䕀ࡼ䗳ᑺব࣪ᯊˈذᴎᯊ䯈гӮবDŽ *...

https://www.fa.omron.com.cn/data_pdf/cat/g9sx-sm_-lm_ca_c_5_1.pdf

PDF1 N X - T C N X - H T C NX-series Temperature Cont...

...block. Refer to the Securing Wires in the USER'S MANUAL for how to secure wires. *2.With the NX-TB@@@1 Terminal Block, use twisted wires to connect the ground terminal. Do not use a solid wir...

https://www.fa.omron.com.cn/data_pdf/cat/nx-tc_nx-htc_h229-e1_2_2_csm1061207.pdf

PDFProgrammable Multi Axis Controller

...rCAT -从站 EtherNet/IP-扫描仪/主站 EtherNet/IP-适配器/从站 Open Modbus/TCP 轴接口板 ACC-24E3 2或4轴数字放大器(PWM)接口 TB连接器或DB-15连接器 ACC-24E3 夹层板数字反馈模拟反馈 ACC-24E3A 2或4轴...

https://www.fa.omron.com.cn/data_pdf/cat/pmac_sbce-cn5-093_1_4.pdf

PDFPMAC Series Programmable Multi Axis Controller

...ave Open Modbus/TCP Axis interface board ACC-24E3 2 or 4-axis digital amplifier (PWM) interface TB connector or DB-15 connector ACC-24E3 Mezzanine Board Digital feedback Analog feedback ACC-2...

https://www.fa.omron.com.cn/data_pdf/cat/pmac_series_r192-e1_2_7_csm1058386.pdf

PDF©OMRON Corporation 2013-2015 All Rights Reserved.

...Incident Light No Incident Light Incident Light ON OFF ON OFF L-ON D-ON ON OFF ON OFF L-ON D-ON Tb Ta Tb ON OFF ON OFF L-ON D-ON Ta (a) (b) One-shot Timer Keeps the output ON for a s...

https://www.fa.omron.com.cn/data_pdf/mnu/e3nc-sa0_inst-5338994-0d.pdf

PDF©OMRON Corporation 2012-2015 All Rights Reserved.

...マ検出してから出力ON を遅らせます。 しゃ光時 ON OFF ON OFF 入光時入光時しゃ光時 ON OFF ON OFF Tb Ta Tb しゃ光時 ON OFF ON OFF Ta (a) (b) ワンショットタイマ検出体の大きさがばらつく場...

https://www.fa.omron.com.cn/data_pdf/mnu/e3nc-saseries___inst-9908894-4i.pdf

PDF 識ムぱン輸叢叢諜統轄鞠1 東京都品川区大崎1-11-1ゲーーートシティ大崎ウエス...

...basicoperation. Forinformationonapplicationsandexplanationsofthesettingdatas,seetheUser'sManual.Tb obtaintheUser'sManualandotheradvancedinformation,see℃eta‖edlnformation"onpage14. 圃はじめに...

https://www.fa.omron.com.cn/data_pdf/mnu/e5ar_e5er_inst-1617413-5a.pdf

結果 481 - 5002231

国/地域選択

Related Contents