IAグローバル検索 |
...tability indicator (green) 10 to 30 VDC Brown (Control output) Load (Relay) 100 mA max. 4 Black ZD 3 Blue 0V Operate Reset (Between brown (1) and black (4) leads) Load (e.g., relay) NEAR FAR ...
https://www.omron-ap.com/data_pdf/cat/e3zm-c_ds_e_5_1_csm2161.pdf
...Circuit D side (DARK ON) Brown 10 to 30 VDC 1 (Control output) Load (Relay) 100 mA max. 4 Black ZD Blue 3 0V Through-beam Emitter Brown Power indicator (green) 1 Photoelectric Sensor Main Cir...
https://www.omron-ap.com/data_pdf/cat/e3zm_ds_e_6_1_csm2159.pdf
... (red) OFF ON Output transistor OFF Operates Load (e.g., relay) Releases Black (Control output) ZD Sensing object EE-SA701-R 12 to 24 VDC ZD EE-SA701P-R ON with no load OFF with no l...
https://www.omron-ap.com/data_pdf/cat/ee-sa701_801_ds_e_4_3_csm662.pdf
...ts caused by power supply problems or ESD transients. Resets include watchdog reset, ,
https://www.omron-ap.com/data_pdf/mnu/84-000830-f_qx-830.pdf
...ts caused by power supply problems or ESD transients. Resets include watchdog reset, ,
https://www.omron-ap.com/data_pdf/mnu/84-000870-g_qx-870.pdf
...DC10∼30V 負 荷 (リレー) 29.2 10.7 L D 出力トランジスタの動作状態 入光時ON しゃ光時ON 青 OV ZD:Vz=39V タイムチャート 入光表示灯 入光 入光 しゃ光 しゃ光 点灯 入光表示灯 ・セ ン サ コ ントロ ...
https://www.omron-ap.com/data_pdf/mnu/e3s-ad14_ad64_inst-6918323-3d.pdf
...のでご注意ください。 (5) ケーブルについて繰り返し屈曲をする使い方はさけてください。 入光表示灯 (赤) (緑) ZD 光電スイッチ主回路 0V ■ 動作モードとタイムチャート 出力トランジスタの動作状態 L...
https://www.omron-ap.com/data_pdf/mnu/e3s-r___inst-5977293-1e.pdf
...0.8 3.2 2 1.2 32.2 15.5 2-M3 M8×1 Light on 2-M3 Load (Relay) ④Black 100mA MAX. (control output) ZD Teaching indicator (red) 31 25.4 31 25.4 10 to 30VDC 0.7 Operation indicator (yellow) ③Blue ...
https://www.omron-ap.com/data_pdf/mnu/e3zm-b_inst-3705140-8d.pdf
...r Load (yellow) (green) (Relay) (Control output) ④Black Photoelectric sensor main circuit 100mA ZD MAX. ③Blue 0V Operation indicator (yellow) 10 to 30VDC ①Brown Stability indicator (green) *...
https://www.omron-ap.com/data_pdf/mnu/e3zm-c____inst-0979013-0g.pdf
...ration Stability indicator indicator indicator indicator Load (orange) (green) (orange) (green) ZD (Relay) Photoelectric ④Black (Control output) ④Black Photoelectric sensor sensor main circui...
https://www.omron-ap.com/data_pdf/mnu/e3zr-c____inst-5367645-0b.pdf
...ROORZLQJGLDJUDP ,IDZLUHLVGLIILFXOWWRFRQQHFWEHFDXVHLWLVWRR WKLQXVHDIODWEODGHVFUHZGULYHULQWKHVDPH ZD\DVZKHQFRQQHFWLQJVWUDQGHGZLUH 0.0 0.0 M M WR WR 40 䗉ޛ JPt100 mv-s M c-d /HDNDJH&XUUHQW 9...
https://www.omron-ap.com/data_pdf/mnu/e5ec-b_inst-5377460-6a.pdf
...することがあります。 フレームグランド端子およびグランド端子を接地して使用してください。 0.1∼1μF 2.5 ZD: ツェナーダイオード ・リレーなどの小型誘導負荷を駆動する際は下図のように配線してくださ...
https://www.omron-ap.com/data_pdf/mnu/ee-spx-w_inst-4361964-5d.pdf
... power supply, try connecting a capacitor (with a capacitance of 0.1 to 1 µF) or a Zener diode (ZD in the diagram below, with a rated voltage of 30 to 35 V). Use the Sensor only after confirm...
https://www.omron-ap.com/data_pdf/mnu/ee-spx301_401_-spy30_40_inst-9977123-7d.pdf
...い。 使用上のご注意 ●取り付け時 ・センサの取り付けの際は、 ソリのない取り付け部に確実につけてください。 ZD Built-in Amplifier Photomicrosensor INSTRUCTION SHEET Thank you for selecting OMRON ...
https://www.omron-ap.com/data_pdf/mnu/ee-spx74_84_inst-1641301-6e.pdf
...あります。 フレームグランド端子およびグランド端子を接地して使用してください。 形EE-SPY311 形EE-SPY411 ●配線時 ZD ー 0.1∼1μF 使用上のご注意 ●取り付け時 ・センサの取り付けの際は、 ソリのない取...
https://www.omron-ap.com/data_pdf/mnu/ee-spy31_41_inst-7484541-4d.pdf
...EE-SX473 形EE-SX474 <サージ対策について> 電源ラインにサージがある場合、 使用環境に応じてツェナーダイオード ZD...
https://www.omron-ap.com/data_pdf/mnu/ee-sx47_67_inst-1845833-5d.pdf
...をしてください。 <サージ対策について> 電源ラインにサージがある場合、 使用環境に応じてツェナーダイオードZD...
https://www.omron-ap.com/data_pdf/mnu/ee-sx95_inst-1680064-8c.pdf
...をしてください。 <サージ対策について> 電源ラインにサージがある場合、 使用環境に応じてツェナーダイオードZD...
https://www.omron-ap.com/data_pdf/mnu/ee-sx97__inst-3705135-1c.pdf
... 26.2 (61.2) Connections Internal Circuit Diagram Indicator Solenoid 10 to 115 VAC/VDC 24 VDC R ZD R E1 (+) LED E2 (−) Constant-current diode 9 D4BL Circuit Connection Example • Terminals 11 ...
https://www.omron.co.id/data_pdf/cat/d4bl_ds_e_10_7_csm1241.pdf
...ction device. 7 D4JL/D4JL-SK40 Connections Internal Circuit Diagram Indicator 24 VDC O1 (+) D R ZD LED O2 () Solenoid 24 VDC E1 (+) E2 () 8 D4JL/D4JL-SK40 Operation Method Operation Principle...