Primary Contents

IAグローバル検索結果

国/地域選択

IAグローバル検索
結果 5041 - 506037360
E5CC-TRX3ASM-002 | OMRON Industrial Automation

... Number of input points 1 point Temperature input Thermocouple: K, J, T, E, L, U, N, R, S, B, C/W, PLII Platinum resistance thermometer: Pt100, JPt100 Infrared Thermosensor: 10 to 70 ℃, 60 to...

https://www.ia.omron.com/product/item/3296/

E5CC-TRX3ASM-003 | OMRON Industrial Automation

... Number of input points 1 point Temperature input Thermocouple: K, J, T, E, L, U, N, R, S, B, C/W, PLII Platinum resistance thermometer: Pt100, JPt100 Infrared Thermosensor: 10 to 70 ℃, 60 to...

https://www.ia.omron.com/product/item/3297/

E5CC-TRX3ASM-004 | OMRON Industrial Automation

... Number of input points 1 point Temperature input Thermocouple: K, J, T, E, L, U, N, R, S, B, C/W, PLII Platinum resistance thermometer: Pt100, JPt100 Infrared Thermosensor: 10 to 70 ℃, 60 to...

https://www.ia.omron.com/product/item/3298/

E5CC-TRX3ASM-005 | OMRON Industrial Automation

... Number of input points 1 point Temperature input Thermocouple: K, J, T, E, L, U, N, R, S, B, C/W, PLII Platinum resistance thermometer: Pt100, JPt100 Infrared Thermosensor: 10 to 70 ℃, 60 to...

https://www.ia.omron.com/product/item/3299/

E5CC-TRX3ASM-006 | OMRON Industrial Automation

... Number of input points 1 point Temperature input Thermocouple: K, J, T, E, L, U, N, R, S, B, C/W, PLII Platinum resistance thermometer: Pt100, JPt100 Infrared Thermosensor: 10 to 70 ℃, 60 to...

https://www.ia.omron.com/product/item/3300/

E5CC-TRX3DSM-000 | OMRON Industrial Automation

...C Allowable voltage variable range 85 to 110% of the power supply voltage Power consumption 2.3 W max. (at 24 VDC) 4.1 VA max. (at 24 VAC) Input Number of input points 1 point Temperature inp...

https://www.ia.omron.com/product/item/3301/

E5CC-TRX3DSM-001 | OMRON Industrial Automation

...C Allowable voltage variable range 85 to 110% of the power supply voltage Power consumption 2.3 W max. (at 24 VDC) 4.1 VA max. (at 24 VAC) Input Number of input points 1 point Temperature inp...

https://www.ia.omron.com/product/item/3302/

E5CC-TRX3DSM-002 | OMRON Industrial Automation

...C Allowable voltage variable range 85 to 110% of the power supply voltage Power consumption 2.3 W max. (at 24 VDC) 4.1 VA max. (at 24 VAC) Input Number of input points 1 point Temperature inp...

https://www.ia.omron.com/product/item/3303/

E5CC-TRX3DSM-003 | OMRON Industrial Automation

...C Allowable voltage variable range 85 to 110% of the power supply voltage Power consumption 2.3 W max. (at 24 VDC) 4.1 VA max. (at 24 VAC) Input Number of input points 1 point Temperature inp...

https://www.ia.omron.com/product/item/3304/

E5CC-TRX3DSM-004 | OMRON Industrial Automation

...C Allowable voltage variable range 85 to 110% of the power supply voltage Power consumption 2.3 W max. (at 24 VDC) 4.1 VA max. (at 24 VAC) Input Number of input points 1 point Temperature inp...

https://www.ia.omron.com/product/item/3305/

E5CC-TRX3DSM-005 | OMRON Industrial Automation

...C Allowable voltage variable range 85 to 110% of the power supply voltage Power consumption 2.3 W max. (at 24 VDC) 4.1 VA max. (at 24 VAC) Input Number of input points 1 point Temperature inp...

https://www.ia.omron.com/product/item/3306/

E5CC-TRX3DSM-006 | OMRON Industrial Automation

...C Allowable voltage variable range 85 to 110% of the power supply voltage Power consumption 2.3 W max. (at 24 VDC) 4.1 VA max. (at 24 VAC) Input Number of input points 1 point Temperature inp...

https://www.ia.omron.com/product/item/3307/

E5DC-QX2ASM-000 | OMRON Industrial Automation

... Number of input points 1 point Temperature input Thermocouple: K, J, T, E, L, U, N, R, S, B, C/W, PLII Platinum resistance thermometer: Pt100, JPt100 Infrared Thermosensor: 10 to 70 ℃, 60 to...

https://www.ia.omron.com/product/item/3361/

E5DC-QX2ASM-002 | OMRON Industrial Automation

... Number of input points 1 point Temperature input Thermocouple: K, J, T, E, L, U, N, R, S, B, C/W, PLII Platinum resistance thermometer: Pt100, JPt100 Infrared Thermosensor: 10 to 70 ℃, 60 to...

https://www.ia.omron.com/product/item/3362/

E5DC-QX2ASM-017 | OMRON Industrial Automation

... Number of input points 1 point Temperature input Thermocouple: K, J, T, E, L, U, N, R, S, B, C/W, PLII Platinum resistance thermometer: Pt100, JPt100 Infrared Thermosensor: 10 to 70 ℃, 60 to...

https://www.ia.omron.com/product/item/3363/

E5DC-QX2DSM-000 | OMRON Industrial Automation

...C Allowable voltage variable range 85 to 110% of the power supply voltage Power consumption 1.5 W max. (at 24 VDC) 2.8 VA max. (at 24 VAC) Input Number of input points 1 point Temperature inp...

https://www.ia.omron.com/product/item/3364/

E5DC-QX2DSM-002 | OMRON Industrial Automation

...C Allowable voltage variable range 85 to 110% of the power supply voltage Power consumption 1.5 W max. (at 24 VDC) 2.8 VA max. (at 24 VAC) Input Number of input points 1 point Temperature inp...

https://www.ia.omron.com/product/item/3365/

E5DC-QX2DSM-017 | OMRON Industrial Automation

...C Allowable voltage variable range 85 to 110% of the power supply voltage Power consumption 1.5 W max. (at 24 VDC) 2.8 VA max. (at 24 VAC) Input Number of input points 1 point Temperature inp...

https://www.ia.omron.com/product/item/3366/

E5DC-RX0ASM-015 | OMRON Industrial Automation

... Number of input points 1 point Temperature input Thermocouple: K, J, T, E, L, U, N, R, S, B, C/W, PLII Platinum resistance thermometer: Pt100, JPt100 Infrared Thermosensor: 10 to 70 ℃, 60 to...

https://www.ia.omron.com/product/item/3367/

E5DC-RX0DSM-015 | OMRON Industrial Automation

...C Allowable voltage variable range 85 to 110% of the power supply voltage Power consumption 1.5 W max. (at 24 VDC) 2.8 VA max. (at 24 VAC) Input Number of input points 1 point Temperature inp...

https://www.ia.omron.com/product/item/3368/