IAグローバル検索 |
... VDC : Brown F39-JDA-D +24 VDC : Brown EDM : Red * 0 VDC : Blue F39-JDA-D S1 S1 +24 VDC +24 VDC KM1 KM1 Power supply KM2 0 VDC Power supply KM2 0 VDC S1: Lockout Reset Switch (When t...
https://www.omron-ap.co.in/data_pdf/mnu/z380-e1-04_f3sg-4ra____-25-01ts.pdf
...Chapter • Cycle the power back ON +24 VDC : Brown EDM : Red * 0 VDC : Blue F39-JDA-D S1 +24 VDC KM1 Power supply KM2 0 VDC S1: Lockout reset switch KM1, KM2: External device *Also us...
https://www.omron-ap.co.in/data_pdf/mnu/z391-e1-03_f3sg-4ar____-25-02ts.pdf
...top pushbutton S1 is pressed. Wiring IN0 IN1 IN2 IN3 IN4 IN5 IN6 IN7 T0 T1 T2 T3 T4 T5 T6 T7 S1 KM1 S2 KM2 A-4 Application Examples KM1 S1: Emergency stop pushbutton KM2 S2: Reset sw...
... Vs-3 V to Vs NPN 0 V to 3 V • In Auto Reset mode PNP NPN 24V/0V (Brown) 24V/0V (Brown) +24 VDC KM1 F3SG-SR/ F3SG-PGA-A/-L receiver, F3SG-PGA-C emitter/receiver F3SG-SR/ F3SG-PGA-A/-L receive...
https://www.omron-ap.co.in/data_pdf/mnu/z405-e1-07_f3sg-sr_pg.pdf
...k release enable signal S5 S4 Feedback loop Emergency Stop Switch Guard lock Safety-door Switch KM1 KM2 S1 S2 KM1 +24V Open Condition monitoring of Safety-door Switch Guard M1 G9SX-B...
https://www.omron-ap.co.nz/data_pdf/cat/a22tk_a189-e1_9_6_csm2088.pdf
...abling Grip Switch. 8 A4EG Feedback loop Lock release enable signal S5 Emergency Stop Switch S4 KM1 KM2 S1 Guard lock Safety-door Switch S2 KM1 +24V Open KM2 A1 T11 T12 T21 T22 T31 T...
https://www.omron-ap.co.nz/data_pdf/cat/a4eg_ds_e_9_1_csm000001266.pdf
...sed while the guard is closed and the emergency stop switch S1 is released. Feedback Loop Guard KM1 S1 Non-contact Safety Door Switch Emergency Stop Switch Actuator S2 KM2 A1 T11 T12 T21 T22 ...
https://www.omron-ap.co.nz/data_pdf/cat/d40a-2_f133-e1_2_2_csm1129085.pdf
... reset mode is selected when terminal T33 is shorted to 24 V. Auto reset mode Manual reset mode KM1 KM2 +24 V T31 T32 Reset switch KM1 Refer to the following illustration for details...
https://www.omron-ap.co.nz/data_pdf/cat/d40a_g9sx-ns_c140-e1_10_6_csm1815.pdf
...hite S3 D2 D3 Blue S1 Non-contact Door Switch Emergency Stop Switch S2 Brown KM2 Guard Actuator KM1 D4 G9SX-NSA222-T03-@ 24 VDC S14 S24 KM1 KM2 S44 S54 L1 X1 NC T41 T42 AND Control c...
https://www.omron-ap.co.nz/data_pdf/cat/d40z_c145-e1_8_4_csm2647.pdf
...ed, the power supply to the motor M is permitted. Lock release enable signal S4 S1: S2: S3: S4: KM1 and KM2: M: S2 E1 E2 41 51 42 52 11 21 31 12 22 32 61 Safety Limit Switch with direct openi...
https://www.omron-ap.co.nz/data_pdf/cat/d4jl_d4jl-sk40_ds_e_10_7_csm1239.pdf
...ct opening mechanism S2: Guard Lock Safety-door Switch S3: Reset switch S4: Lock release switch KM1 and KM2: Magnetic contactor M: Motor 54 41 53 12 32 11 31 Condition monitoring of Safety-do...
https://www.omron-ap.co.nz/data_pdf/cat/d4nl_ds_e_9_9_csm1240.pdf
...chanism S2: Guard Lock Safety-door Switch D4SL-N@E@A-@ S3: Reset switch S4: Lock release switch KM1 and KM2: Magnetic contactor M: Motor S2 10 42 64 41 1 63 12 22 34 11 21 33 2 3 4 5 6 7 8 Co...
https://www.omron-ap.co.nz/data_pdf/cat/d4sl-n_c146-e1_8_8_csm1004285.pdf
...RANGE SELECT INPUT (Yellow) *2 Not used (White) 0V/24V (Blue) Emitter Receiver [Wiring Example] KM1 KM2 M S2 KM1 S1 Needed KM1 KM2 Wiring for NPN *1 KM2 24 VDC 24 VDC *3 : ...
https://www.omron-ap.co.nz/data_pdf/cat/f3sg-sr_pg_f117-e1_1_8_csm1120108.pdf
...tor M is kept OFF until the beams are unblocked and the reset switch S2 is pressed. +24 V +24 V KM1 +24 V Feedback loop KM2 (Gray) Communication line (+) K1 K1 K2 K2 K3 K3 K1 K3 K2 K3 ...
https://www.omron-ap.co.nz/data_pdf/cat/f3sj_f074-e1_27_11_csm1816.pdf
...S2 Auxiliary contact A1 H1 L1 J1 H1 TEST INTERLOCK OSSD1 Receiver OSSD2 13 23 33 41 X1 RESET K1 KM1 K2 Emitter K1 K2 EDM A2 PE T31 T32 KM2 P1 14 24 34 42 F3SP-B1P KM1 KM1 * ...
https://www.omron-ap.co.nz/data_pdf/cat/f3sp-b1p_ds_e_5_1_csm1067236.pdf
...r M is kept OFF until the guard is closed. Timing Chart 23 S2 Limit switches S1 and S2 24 Guard KM1 and KM2 (NO) 11 S1 Feedback loop 12 KM1 KM2 open S1: S2: KM1 and KM2: M: ...
https://www.omron-ap.co.nz/data_pdf/cat/g9sa-p_f106-e1_6_2_csm1070131.pdf
...e motor M is kept OFF until the guard is closed. Timing Chart Limit switches S1 and S2 23 S2 24 KM1 and KM2 (NO) Guard 11 S1 Feedback loop 12 KM1 KM2 S1: S2: KM1 and KM2: M:...
https://www.omron-ap.co.nz/data_pdf/cat/g9sa_ds_e_11_15_csm1281.pdf
...otor M is kept OFF until the guard is closed. Timing Chart S2 Guard Limit switches S1 and S2 S1 KM1 and KM2 (NO) KM1 KM2 Open Feedback loop S1: S2: KM1 and KM2: M: * * A1 A2...
https://www.omron-ap.co.nz/data_pdf/cat/g9sb_ds_e_6_7_csm1282.pdf
...nd reset switch S2 is pressed. Feedback loop S1 Timing Chart S2 Emergency stop switch operation KM1 Emergency stop switch S1 KM2 Reset switch S2 KM1, KM2 NO contact A1 T11 T12 T31 T3...
https://www.omron-ap.co.nz/data_pdf/cat/g9se_j198-e1_4_7_csm1040781.pdf
...ring Example: Emergency Stop (Dual Channel) with Manual Reset Estop Reset V1 G1 Si0 Si1 So0 So1 KM1 KM2 Si2 Si3 KM1 KM1 KM2 KM2 G9SP V2 DC24V G2 T0 T1 T2 T3 M 21 G9SP Dimens...
https://www.omron-ap.co.nz/data_pdf/cat/g9sp_f090-e1_12_9_csm2603.pdf