IAグローバル検索 |
...t C120-LK201 (RS-232C) C120-LK202 (RS-422)* Built-in Host Link port *To replace C120-LK202, use NT-AL001 to convert RS-232C into RS-422. Power Supply Unit (For C200H-CPU01/02/21/22) C200HW-PA...
https://www.omron.com.tw/data_pdf/mnu/p069-e1-06_c200h_cs1_replace.pdf
...le) RS-232C port (D-Sub 9-pin male) Loop Control Unit CS1 CPU Unit RS-232C/422A Conversion Unit NT-AL001 RS-485 2-wire connection (500 m max.) RS-232C (15 m max.) (Provided with Loop Control ...
https://www.omron.com.tw/data_pdf/mnu/w375-e1-05_cs1w-lc001.pdf
...he RS-232C port on the CPU Unit to any external device except the CJ1W-CIF11 RS-422A Adapter or NT-AL001 RS-232C/RS-422A Adapter. Doing so may damage the external device or Loop Control Board...
https://www.omron.com.tw/data_pdf/mnu/w406-e1-10_cs1w-lcb_cs1d-cpu_cs1g-cpu.pdf
...t pin 6 (+5V) on the RS-232C Option Board on the CPU Unit to any external device other than the NT-AL001 or CJ1W-CIF11 Conversion Adapter. The external device and the CPU Unit may be damaged....
https://www.omron.com.vn/data_pdf/mnu/cpseries(safetyprecautions)_inst-1118339-0e.pdf
...t pin 6 (+5V) on the RS-232C Option Board on the CPU Unit to any external device other than the NT-AL001 or CJ1W-CIF11 Conversion Adapter. The external device and the CPU Unit may be damaged....
https://www.omron.com.vn/data_pdf/mnu/cpseries(safetyprecautions)_inst-1131255-6b.pdf
...ᣦ♧ࡉࢀࡓ᪉ἲ࡛⾜ࡗ࡚ࡃࡔࡉ࠸ࠋ ەCPU ࣘࢽࢵࢺ╔ࡋࡓ RS-232C ࢜ࣉࢩ࣮ࣙࣥ࣎ࢻࡢ 6 ␒ࣆࣥ㸦+5V 㟁※㸧ࡣࠊኚ ࢲࣉࢱ ᙧ CJ1W-CIF11/ᙧ NT-AL001 ௨እࡢእ㒊ᶵჾࡣ᥋⥆ࡋ࡞࠸࡛ࡃࡔࡉ࠸ࠋእ 㒊ᶵჾ࠾ࡼࡧ CPU ࣘࢽࢵࢺࡀᨾ㞀ࡍࡿᜍࢀࡀ࠶ࡾࡲࡍࠋ ە᥋⥆ࢣ࣮ࣈࣝࡣྛࣘ...
https://www.omron.com.vn/data_pdf/mnu/cpseries(safetyprecautions)_inst-1131256-4b.pdf
...ᣦ♧ࡉࢀࡓ᪉ἲ࡛⾜ࡗ࡚ࡃࡔࡉ࠸ࠋ ەCPU ࣘࢽࢵࢺ╔ࡋࡓ RS-232C ࢜ࣉࢩ࣮ࣙࣥ࣎ࢻࡢ 6 ␒ࣆࣥ㸦+5V 㟁※㸧ࡣࠊኚ ࢲࣉࢱ ᙧ CJ1W-CIF11/ᙧ NT-AL001ࠊࣉࣟࢢ࣐ࣛࣈࣝࢱ࣮࣑ࢼࣝᙧ NV3W-Mڧ20L ௨እࡢ እ㒊ᶵჾࡣ᥋⥆ࡋ࡞࠸࡛ࡃࡔࡉ࠸ࠋእ㒊ᶵჾ࠾ࡼࡧ CPU ࣘࢽࢵࢺࡀᨾ㞀...
https://www.omron.com.vn/data_pdf/mnu/cpseries(safetyprecautions)_inst-2104744-3c.pdf
...t pin 6 (+5V) on the RS-232C Option Board on the CPU Unit to any external device other than the NT-AL001 or CJ1W-CIF11 Conversion Adapter or NV3W-Mƶ20L Programmable terminal. The external dev...
https://www.omron.com.vn/data_pdf/mnu/cpseries(safetyprecautions)_inst-2104888-1c.pdf
...で行ってください。 ●CPU ユニットに装着した RS-232C オプションボードの 6 番ピン (+5V 電源) は、変換アダプタ 形CJ1W-CIF11/形NT -AL001 以外の外部機器には接続し ●l ithium1次電池( 過塩素塩酸含有...
https://www.omron.com.vn/data_pdf/mnu/cpseries(safetyprecautions)_inst-4074765-0e.pdf
...urrent protection. • Do not use the +5 V output from the CP1W-CIF01 for anything other than the NT-AL001. • A G9SP-series Controller has two sets of power supply terminals, one for the main p...
https://www.omron.com.vn/data_pdf/mnu/g9sp-n10s_n10d_n20s_inst-2114042-7f.pdf
...5 2-wire connection (500 m max.) RS-232C port (D-Sub 9-pin female) RS-232C/422A Conversion Unit NT-AL001 ES100X (with RS-422A/485 serial communications) ES100 04 32 Controllers max. Wiri...
https://www.omron.com.vn/data_pdf/mnu/w375-e1-05_cs1w-lc001.pdf
...す。 ・CPU ユニットの RS-232C ポートの 6 番ピン(+5V 電源)は、RS-422A 変換アダプタ(形 CJ1W-CIF11)、RS-232C/RS-422A 変換ユニット(形 NT-AL001)、プログラマブルターミナル(形 NV3W-M□20L)以...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/sbca-313p-1_cs_cj_prog.pdf
.... 2-14 PT本体のシステムメニューの操作 ................................................................. 2-15 形NT-AL001の設定 ....................................................................
https://www.fa.omron.co.jp/data_pdf/closed/mnu/sccp-303d-10_nt.pdf
... the RS-232C port on the CPU Unit to any external device except the CJ1W-CIF11 RS-422A Adapter, NT-AL001 RS-232C/RS-422A Adapter, or NV3W-M@20L Programmable Terminal. Doing so may damage the ...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/w394-e1-16_cs_cj_nsj.pdf
...onnect pin 6 (5-V power supply) on the RS-232C port on the CPU Unit to any device other than an NT-AL001 or CJ1W-CIF11 Adapter. The external device or the CPU Unit may be damaged. •Before tou...
https://www.fa.omron.com.cn/data_pdf/closed/mnu/w342-e1-18_cs1_cj1_cp1_com_cmd.pdf
...4□□□ NJ501-5300 NJ501-□□□□ NP3 NP5 NS-NSRCL1 / 3 / 10 NS5, NS8, NS10, NS12, NS15, NSH5-V2 NSJ系列 NT-AL001 NT11 / NT21 NT20 首页 上一页 6 7 8 9 10 下一页 尾页...
https://www.fa.omron.com.cn/index.php?cat_code=/document&part=1769&p=9
...两台PLC的RS422口并在一起接至上位机的RS422口,但使用B500-AL001可保证接线的可靠性,且对用户来说使用起来也很方便。 2、除了NT-AL001可用作RS-232C和RS-422的转换,一般市面上的RS232转RS422口的适配...
...M1A-TS102/CPM1A-DA041,CPU单元上的服务电源DC24V的电流不应超过200mA 3:若安装了二或三个CPM1A-DA041单元,CPU上的DC24V的电源不能使用 4:若NT-AL001的RS-422适配器被连接到RS-232端口,则只能连接一个...
...t connect pin 6 (+5V) on the RS-232C port on the CPU Unit to any external device other than the NT-AL001 or CJ1W-CIF01 Conversion Adapter. The external device and the CPU Unit may be damaged....
...内蔵 RS-232C RS-232C ポート 注 1: CPU 取付タイプ上位リンクユニットとして、形 C120-LK202(RS-422A タイプ)を使用している場合は、形 NT-AL001 または形 CJ1W-CIF11 を使用して、RS-232C を RS-422A ...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/sbca-328m-1_c500_c1000h_c2000h.pdf