IAグローバル検索 |
...形G9SA-301形G9SA-501 形G9SA-321-T□形G9SA-TH301 AC/DC24V セーフティリレーユニット各部の名称 0622108-9 L (1)配線をおこなう場合には必ず電源を切った状態でおこなって...
https://www.omron.com.tw/data_pdf/mnu/g9sa-301_-501_-321-t__-th301(ac_dc24v)_inst-0622108-9l.pdf
...寸法製品本体のマーキングを参照ください。 出力端子出力端子電源表示動作表示オフディレ-時間設定スイッチ (G9SA-EX031-T□) 41 33 23 13 24 14 42 34 87±0.3 2-φ4.2またはM4 43 42 5.6 R2.3 17.5以下 63 ...
https://www.omron.com.tw/data_pdf/mnu/g9sa-ex301_ex031-t__inst-0622109-7j.pdf
...ting Sensors 135 Connecting to an F3SP-B1P 136 Connecting to an F3SX-E-L2R2 137 Connecting to a G9SA-301 138 Connecting to a G9SA-300-SC 139 Connecting to a G9SB-301-D 140 Connecting...
https://www.omron.com.tw/data_pdf/mnu/schg-716n_eng_f3sj-am.pdf
...ting Sensors 169 Connecting to an F3SP-B1P 170 Connecting to an F3SX-E-L2R2 171 Connecting to a G9SA-301 172 Connecting to a G9SA-300-SC 173 Connecting to a G9SB-301-D 174 Connecting...
https://www.omron.com.tw/data_pdf/mnu/schg-718s_eng_f3sj-a.pdf
...g only F3SJ 167 Connecting 2 Muting Sensors 168 Connecting 4 Muting Sensors 169 Connecting to a G9SA-301-P 170 Using a Simple Wiring Connector 171 Chapter6 Checklists 173 Pre-Operation Checkl...
https://www.omron.com.tw/data_pdf/mnu/schg-719s_eng_f3sj-a.pdf
... Muting Sensors 97 Connecting to an F3SP-B1P 98 Connecting to an F3SX-E-L2R2 99 Connecting to a G9SA-301 100 Connecting to a G9SA-300-SC 101 Connecting to a G9SB-301-D 102 Connecting...
https://www.omron.com.tw/data_pdf/mnu/schg-720r_eng_f3sj-a.pdf
...uting Sensors 99 Connecting to an F3SP-B1P 100 Connecting to an F3SX-E-L2R2 101 Connecting to a G9SA-301 102 Connecting to a G9SA-300-SC 103 Connecting to a G9SB-301-D 104 Connecting...
https://www.omron.com.tw/data_pdf/mnu/schg-722n_eng_f3sj-a.pdf
...ircuit and Applications E Connecting a F3SJ-E to Various Controllers Connecting a F3SJ-E to a G9SA-301 Controller Unblocked Blocked External test/lockout reset switch (S1) Interlock reset s...
https://www.omron.com.tw/data_pdf/mnu/schg-732k_eng_f3sj-e____p25_b____p25.pdf
...ircuit and Applications E Connecting a F3SJ-E to Various Controllers Connecting a F3SJ-E to a G9SA-301-P Controller M KM1 KM2 T23 PE 14 24 34 42 41 33 23 13 T32 T31 T11 KM1 KM2 T12 K1 K1 K2...
https://www.omron.com.tw/data_pdf/mnu/schg-733j_eng_f3sj-e____n25_b____n25.pdf
...nual Chapter4 Wiring Examples Input/Output Circuit and Applications E Connecting a F3SJ-B to a G9SA-301 Unblocked Blocked External test switch (S1) Interlock reset switch (S2) Emergency stop...
https://www.omron.com.tw/data_pdf/mnu/schg-734j_eng_f3sj-b____p25-01ts.pdf
... Circuit and Applications Connecting a F3SJ-B to Various Controllers Connecting a F3SJ-B to a G9SA-301-P M OUT PLC KM1 KM2 IN1 IN2 KM3 T23 PE 14 24 34 42 41 33 23 13 T32 T31 T11 KM1 KM2 T12...
https://www.omron.com.tw/data_pdf/mnu/schg-735j_eng_f3sj-b____n25-01t.pdf
...g Examples F3SJ-B User’s Manual Input/Output Circuit and Applications Connecting a F3SJ-B to a G9SA-301 Unblocked Blocked External test switch (S1) Interlock reset switch (S2) Emergency stop...
https://www.omron.com.tw/data_pdf/mnu/schg-736j_eng_f3sj-b____p25-02ts.pdf
...nnection with Single OS32C unit 125 Connecting to AGV Controls 126 Connecting to the Controller G9SA-301 127 122 Chapter5 OS32C User’s Manual Wiring Power Supply Unit Do not connect the OS32C...
...onnectable to units supporting IO-Link Version 1.1. Connectable safety controllers (PNP output) G9SA-301 G9SA-321-T G9SA-501 G9SB-200-B G9SB-200-D G9SB-301-B G9SB-301-D G9S...
https://www.omron.com.tw/data_pdf/mnu/z405-e1-07_f3sg-sr_pg.pdf
...tch * D40A Solution 1 D40B-J1 Emergency stop switch * The D40A Simplifies the Configuration The G9SA must be added to connect the G9SA emergency stop switch. Two Controllers Issue 2 ...
https://www.omron.com.vn/data_pdf/cat/d40a_g9sx-ns_c140-e1_10_6_csm1815.pdf
...D4NL-@C@A-@, -@G@A-@ (Mechanical Lock Type) Safety Limit Switch D4B-N/D4N/D4F Safety Relay Unit G9SA-301 (24 VAC/VDC) Stop category Reset 0 Manual Note: The above PL is only the evaluation re...
https://www.omron.com.vn/data_pdf/cat/d4nl_ds_e_9_9_csm1240.pdf
...o the safety controllers listed in the table below. Connectable safety controllers (PNP output) G9SA-301 G9SA-321-T G9SA-501 G9SB-200-B G9SB-200-D G9SB-301-B G9SB-301-D G9S...
https://www.omron.com.vn/data_pdf/cat/f3sg-sr_pg_f117-e1_1_8_csm1120108.pdf
...Power supply GND KM1 KM2 M Feedback loop 27 F3SJ-E Wiring to connect a F3SJ-E with a controller G9SA-301 [PNP Output] Highest achievable PL/ safety category Model Stop category Safety Light C...
https://www.omron.com.vn/data_pdf/cat/f3sj_f074-e1_27_11_csm1816.pdf
...pplication in feedback circuits of safety circuits. Application Example: General Safety Circuit G9SA-301 (24-V AC/DC) (two limit switch input channels with manual reset) Feedback circuit Feed...
https://www.omron.com.vn/data_pdf/cat/g7z_j160-e1_10_1_csm1001495.pdf
...Safety Relay Unit with negative common (NPN) G9SA-P Units with negative common (NPN) join G9SA Series • Four kinds of 45-mm wide Units are available: A 3-pole model, a 5-pole model, ...
https://www.omron.com.vn/data_pdf/cat/g9sa-p_f106-e1_6_2_csm1070131.pdf