IAグローバル検索 |
...Z Control output Output type Complementary output Output voltage VH: Vcc -3 V min. (IO = 30 mA) VL: 2 V max. (IO = -30 mA) Load current ±30 mA Max. response frequency 125 kHz (65 kHz when usi...
https://www.fa.omron.co.jp/product/item/E6C3-CWZ5GH_500P_R_1M/en/
...Z Control output Output type Complementary output Output voltage VH: Vcc -3 V min. (IO = 30 mA) VL: 2 V max. (IO = -30 mA) Load current ±30 mA Max. response frequency 125 kHz (65 kHz when usi...
https://www.fa.omron.co.jp/product/item/E6C3-CWZ5GH_500P_R_2M/en/
...Z Control output Output type Complementary output Output voltage VH: Vcc -3 V min. (IO = 30 mA) VL: 2 V max. (IO = -30 mA) Load current ±30 mA Max. response frequency 125 kHz (65 kHz when usi...
https://www.fa.omron.co.jp/product/item/E6C3-CWZ5GH_600P_R_1M/en/
...Z Control output Output type Complementary output Output voltage VH: Vcc -3 V min. (IO = 30 mA) VL: 2 V max. (IO = -30 mA) Load current ±30 mA Max. response frequency 125 kHz (65 kHz when usi...
https://www.fa.omron.co.jp/product/item/E6C3-CWZ5GH_600P_R_2M/en/
...Z Control output Output type Complementary output Output voltage VH: Vcc -3 V min. (IO = 30 mA) VL: 2 V max. (IO = -30 mA) Load current ±30 mA Max. response frequency 125 kHz (65 kHz when usi...
https://www.fa.omron.co.jp/product/item/E6C3-CWZ5GH_720P_R_1M/en/
...Z Control output Output type Complementary output Output voltage VH: Vcc -3 V min. (IO = 30 mA) VL: 2 V max. (IO = -30 mA) Load current ±30 mA Max. response frequency 125 kHz (65 kHz when usi...
https://www.fa.omron.co.jp/product/item/E6C3-CWZ5GH_720P_R_2M/en/
...Z Control output Output type Complementary output Output voltage VH: Vcc -3 V min. (IO = 30 mA) VL: 2 V max. (IO = -30 mA) Load current ±30 mA Max. response frequency 125 kHz (65 kHz when usi...
https://www.fa.omron.co.jp/product/item/E6C3-CWZ5GH_800P_R_1M/en/
...Z Control output Output type Complementary output Output voltage VH: Vcc -3 V min. (IO = 30 mA) VL: 2 V max. (IO = -30 mA) Load current ±30 mA Max. response frequency 125 kHz (65 kHz when usi...
https://www.fa.omron.co.jp/product/item/E6C3-CWZ5GH_800P_R_2M/en/
...Z Control output Output type Complementary output Output voltage VH: Vcc -3 V min. (IO = 30 mA) VL: 2 V max. (IO = -30 mA) Load current ±30 mA Max. response frequency 83 kHz Phase difference ...
https://www.fa.omron.co.jp/product/item/E6F-CWZ5G_1000P_R_2M/en/
...Z Control output Output type Complementary output Output voltage VH: Vcc -3 V min. (IO = 30 mA) VL: 2 V max. (IO = -30 mA) Load current ±30 mA Max. response frequency 83 kHz Phase difference ...
https://www.fa.omron.co.jp/product/item/E6F-CWZ5G_100P_R_2M/en/
...Z Control output Output type Complementary output Output voltage VH: Vcc -3 V min. (IO = 30 mA) VL: 2 V max. (IO = -30 mA) Load current ±30 mA Max. response frequency 83 kHz Phase difference ...
https://www.fa.omron.co.jp/product/item/E6F-CWZ5G_200P_R_2M/en/
...Z Control output Output type Complementary output Output voltage VH: Vcc -3 V min. (IO = 30 mA) VL: 2 V max. (IO = -30 mA) Load current ±30 mA Max. response frequency 83 kHz Phase difference ...
https://www.fa.omron.co.jp/product/item/E6F-CWZ5G_360P_R_2M/en/
...Z Control output Output type Complementary output Output voltage VH: Vcc -3 V min. (IO = 30 mA) VL: 2 V max. (IO = -30 mA) Load current ±30 mA Max. response frequency 83 kHz Phase difference ...
https://www.fa.omron.co.jp/product/item/E6F-CWZ5G_500P_R_2M/en/
...Z Control output Output type Complementary output Output voltage VH: Vcc -3 V min. (IO = 30 mA) VL: 2 V max. (IO = -30 mA) Load current ±30 mA Max. response frequency 83 kHz Phase difference ...
https://www.fa.omron.co.jp/product/item/E6F-CWZ5G_600P_R_2M/en/
... 40 50 60 Side length of sensing object: d (mm) Residual Output Voltage Residual output voltage VL (V) E2EV 0.8 0.6 0.4 0.2 0 1 3 5 7 10 30 50 70 100 Load current (mA) 3 E2EV I/O Circuit Diag...
https://www.fa.omron.co.jp/data_pdf/closed/cat/e2ev_ds_e_6_2_csm450.pdf
...さd (㎜) 0 10 20 30 40 50 60 検出物体一辺の長さd (㎜) 負荷電圧 ︵V︶ 残留電圧特性形E2EV 0.8 VL 0.6 0.4 0.2 0 1 3 5 7 10 30 50 70 100 負荷電流 (mA) ご購入 当社販売店 または オムロンFA...
https://www.fa.omron.co.jp/data_pdf/closed/cat/e2ev_ds_j_6_3.pdf
....6k ×24V=13V 入力電圧VH= Vcc= 4.7k+5.6k R+Z 〈“L”レベル時〉 Vcc 24V = =5.1mA≦50mAより負荷電流Ic= R R 入力電圧VL≦1.0V(負荷電流50mA時の残留電圧) 注.負荷電流に対する残留電圧はセンサの...
https://www.fa.omron.co.jp/data_pdf/closed/cat/ee-sx91_ds_j_7_4.pdf
... ⑦QM Viewer ⑧メモリカード128MB ⑨モニタケーブル お問い合わせ 0120-919-066 形式形QM519-C10 形QM300-KP01 形QM300-AL 形QM300-VL 形QM300-VK 形QM300-RS ── 形QM300-N128S 形F150-VM 詳細情報は 標準価...
.../最新の商品情報は 20 30 40 50 60 検出物体の一辺の長さd (㎜) 2 TL-M 出力残留電圧 ON 100 ︶ VL V AC100V時 形TL-M□MY1 負荷電圧 ︵V︶ 負荷電圧 ︵ 残留電圧特性形TL-M□MY1 VL AC200V時 出...
https://www.fa.omron.co.jp/data_pdf/closed/cat/tl-m_ds_j_3_1.pdf
...0 −8 −6 −4 −2 0 4 2 8 0 AC100V時 ON 100 10 15 20 25 0 5 10 15 形TL-T□ (M)Y□ VL AC200V時 出力残留電圧 200 ON 20 t=1mm 25 30 35 40 検出物体一辺の長さ d (㎜) 検出物体一辺の長さ d (㎜) 負荷...
https://www.fa.omron.co.jp/data_pdf/closed/cat/tl-t_ds_j_2_2.pdf