| IAグローバル検索 |
... ON ON ON OFF 15 ON ON ON ON Note: Be sure to perform settings with the Slave power supply OFF. 61 SRT2-VID/VOD(-1) SRT2-VID/VOD(-1) Dimensions Note: All units are in millimeters unless other...
https://www.omron.co.id/data_pdf/cat/compobus_s_q103-e1-07.pdf
...e immunity Conforms to IEC 61000-4-4 2 kV (applied to power supply). Vibration resistance 10 to 61.2 Hz with single-amplitude of 0.1 mm, 61.2 to 150 Hz and 14.7 m/s2 in X, Y, and Z d...
https://www.omron.co.id/data_pdf/cat/crt1_crt1b_componet_p056-e1_17_10_csm2176.pdf
...munity Conforms to IEC 61000-4-4 2 kV (applied to PLC power supply). Vibration resistance 10 to 61.2 Hz with single-amplitude of 0.1 mm, 61.2 to 150 Hz and 14.7 m/s2 in X, Y, and Z d...
https://www.omron.co.id/data_pdf/cat/cs1w-crm21_ds_e_9_5_csm1636.pdf
...therNet/IP Unit. Network Configurator version 3.74a or higher is included with CX-One version 4.61 or higher. The Network Configurator provides the following functions for building, setting, ...
https://www.omron.co.id/data_pdf/cat/cs1w-eip21_eip21s_ds_e_7_9_csm1782.pdf
...M2C-S100C/110C CPM2C-S110C-DRT CQM1 CQM1-CPU11/21/41/42/43/44/45 CQM1H-series CQM1H-CPU11/21/51/61 CV1000 CV1000-CPU01 (-V1) CV2000 CV2000-CPU01 (-V1) CV500 CV500-CPU01 (-V1) CVM1 CVM1-CPU01/...
https://www.omron.co.id/data_pdf/cat/cx-programmer_ds_e_11_10_csm2060.pdf
...Z/CPU85-Z C200HG-CPU33-Z/CPU43-Z/CPU53-Z/CPU63-Z C200HE-CPU32-Z/CPU42-Z CQM1H CQM1H-CPU11/21/51/61 Communication Boards/Units Series Serial Communication I/O Unit CS1W-SCU21(-V1)/SCU31-V1/SCB...
https://www.omron.co.id/data_pdf/cat/cx-protocol_ds_e_7_9_csm2078.pdf
...T Double-break D4A-3@08N D4A-4@06N D4A-4@07-HN D4A-4@07-VN D4A-4@08N Operating force OF max. 19.61 N 19.61 N 19.61 N 19.61 N 19.61 N 19.61 N ...
https://www.omron.co.id/data_pdf/cat/d4a-_n_ds_e_4_7_csm584.pdf
... speed 0.05 to 0.5 m/s Operating frequency 30 operations/minute max. Direct opening force *3 19.61 N min. (EN60947-5-1) Direct opening travel *3 20 mm min. (EN60947-5-1) Holding force (Fzh) 7...
https://www.omron.co.id/data_pdf/cat/d4bl_ds_e_10_7_csm1241.pdf
...eed 0.1 m/s to 0.5 m/s Operating frequency 30 operations/minute max. Direct opening force *3 19.61 N min. (EN60947-5-1) Direct opening travel *3 20 mm min. (EN60947-5-1) Contact resistance 25...
https://www.omron.co.id/data_pdf/cat/d4bs_ds_e_8_7_csm1237.pdf
...nal 31/33 Terminal 32/34 LED indicator Terminal 41 Terminal 42 Terminal 51 Terminal 52 Terminal 61/63 Terminal 62/64 41 42 11 12 51 52 21 22 63 64 33 34 Conduit outlet Conduit outlet Note: Th...
https://www.omron.co.id/data_pdf/cat/d4jl_d4jl-sk40_ds_e_10_7_csm1239.pdf
...42- 1 11 (NC) 4 52- 3 21 (NC) 3 21- 4 22 (NC) 5 31- 6 32 (NC) 5 33- 6 34 (NO) 1 41- 2 42 (NC) 7 61- 8 62 (NC) 7 63- 8 64 (NO) Condition 2 Door closed. The door is locked. Turning the special ...
https://www.omron.co.id/data_pdf/cat/d4sl-n_c146-e1_8_8_csm1004285.pdf
...-C2 27 (39) PNP E2A-S08KS02-M5-B1 E2A-S08KS02-M5-B2 NPN E2A-S08KS02-M5-C1 E2A-S08KS02-M5-C2 49 (61) PNP E2A-S08LS02-M5-B1 E2A-S08LS02-M5-B2 NPN E2A-S08LS02-M5-C1 E2A-S08LS02-M5-C2 E2A-S08KN04...
https://www.omron.co.id/data_pdf/cat/e2a_dsheet_d100-e1-01b.pdf
... washer Long Body E2B-M18LS05-M1-@@/E2B-M18LS08-M1-@@ E2B-M18LN10-M1-@@/E2B-M18LN16-M1-@@ 81 81 61 4 24 Operating indicator (yellow LED 4×90°) 24 10 61 4 Operating indicator (yellow ...
https://www.omron.co.id/data_pdf/cat/e2b_d116-e1_1_6_csm1012652.pdf
...ng nuts Long Body E2B-M18LS05-M1-@@/E2B-M18LS08-M1-@@ E2B-M18LN10-M1-@@/E2B-M18LN16-M1-@@ 81 81 61 4 24 Operating indicator (yellow LED 4×90°) 24 10 61 4 Operating indicator (yellow ...
https://www.omron.co.id/data_pdf/cat/e2b_d118-e1_1_3_csm1014203.pdf
...ta sheet unless otherwise specified. E2KQ-X10ME@ Sensitivity adjustment screw *1 Fluorine resin 61.8 24 20 8 Detection indicator (red) Indicator Mounting Hole Dimensions 16 dia. M18 u 1.5 Flu...
https://www.omron.co.id/data_pdf/cat/e2kq-x_ds_e_4_5_csm461.pdf
...atibility mounting (without mounting pitch Vertical compatibility) mounting SUS 304, 2 mm thick 61 M6 screws Top mounting 56 34 E39-L93H E39-L93V E39-L93FH E39-L93FV E39-L93FH E39-L93FV Use t...
https://www.omron.co.id/data_pdf/cat/e39-l__ds_e_5_2_csm415.pdf
...56 dia. Four, R3.3 E3S-R 8.2 Two, R22 4 6.5 (For E3S-B) (For E3S-R) (For E3Z) An attached screw 61 25.4 16 20 48 38.5 25 16 (A)* 2 56 * Mounting Bracket can be attached to side (A) 8 24 34 Ma...
https://www.omron.co.id/data_pdf/cat/e39-l_f39-l_e39-s_e39-r_ds_e_19_10_csm416.pdf
...ors (with MSR function) Through-beam Sensors Sensing method E3S-AT11, 16, 21, 31, Model 36, 41, 61, 66, 71, 81, 86, 91 Item E3S-AR11, 16, 21, 31, 36, 41, 61, 66, 71, 81, 86, 91 E3S-A...
https://www.omron.co.id/data_pdf/cat/e3s-a_ds_e_13_1_csm1296.pdf
....9 R1 26.2 Two, 4.5-dia. holes 29.9 (3) 5 R49.9 ±0.1 20 4.5 4.5 d 25.4 ia. 40±0.1 R3.5 5 61.8 R2 4.5 58.8 R2.25 54.5 90°±0.5° 23.8 33.3 8.8 R3 max. 5° 31.8 R5 30° R2.25 10.1 (3) 47.6 54.5 15 ...
https://www.omron.co.id/data_pdf/cat/e3s-db_e439-e1_2_5_csm1042734.pdf
...lengths: 2 m, 0.5 m 20 2 4 1 3 M8 11 Operation Indicator (orange) * On the other side Note: E3G-61/G81: 1-axis models (S1) E3G-62/G82: 2-axis models (S1, S2) *S1 output: Black *S2 output: Whi...
https://www.omron.co.id/data_pdf/cat/e3z-g_ds_e_9_5_csm434.pdf