Primary Contents

IAグローバル検索結果

国/地域選択

IAグローバル検索
結果 7861 - 788021443
PDFCSM_E3S-A_DS_E_13_1 1 Built-in Amplifier Photoelec...

...e Reset Light indicator (red) (Between brown and black) Output transistor Load (e.g., relay) 12 K (External diagnostic input) (Self-diagnostic output) ZD Light indica- tor Stability indicator...

https://www.fa.omron.com.cn/data_pdf/cat/e3s-a_ds_e_13_1_csm1296.pdf

PDFCSM_E3Z-B_DS_E_10_1 1 Photoelectric Sensor with Bu...

...cator (green) 8 Connector Models E3Z-B66 E3Z-B86 E3Z-B67 E3Z-B87 M8 Pre-wired Connector (E3Z-T@@K-M3J) M12 Pre-wired Connector (E3Z-@@@-M1J) 4 dia. vinyl-insulated round cable with 3 conducto...

https://www.fa.omron.com.cn/data_pdf/cat/e3z-b_ds_e_10_1_csm433.pdf

PDF单光束安全传感器E3ZS/E3FS 产品线................................

...开的最小距离。 人体垂直进入传感器的检测区域时,安全距离可按下示的方法计算。 安全距离(S)=进入检测区域的速度(K) ×设备和传感器的总响应时间(T) +由传感器最小检测物体直径计算的添加距离 (C) ...

https://www.fa.omron.com.cn/data_pdf/cat/e3zs_e3fs_ds_c_1_1.pdf

PDF1 CSM_E5_N_E5_N-H_operation_TG_E_4_4

....a 2h 0.0 0. a 2l 0.0 0. a 0.0 -3 0.a 3h 0.0 0. a 3l 0.0 0.a 1 0. s o k off 0.w t b 2l 0.0 7. a 0.0 -3 7.a 3h 0. 0 7. a 3l 0. 0 7. a 1 7. s o k of f 7. w t b 7.lsp 0.0 7.pid 1 7.s p ...

https://www.fa.omron.com.cn/data_pdf/cat/e5_n_e5_n-h_e5_n-ht_operation_tg_e_4_4_csm1375.pdf

PDFn E5 R选型指南 14种型号(尺寸分别为96×96mm或96×48mm)可供选择

...线性电流输出: 4~20 mA, 0~20 mA脉冲电压输出: 12 VDC, PNP继电器输出:位置比例每行显示位数:5显示行数:3 100~240 VAC, 24 VAC/VDC K, J, T, E, L, U, N, R, S, B, W, Pt100, 1~5 V, 0~5 V, 0~10 V...

https://www.fa.omron.com.cn/data_pdf/cat/e5_r_h121-c1-01.pdf

PDF1 400-820-4535 www.fa.omron.com.cn૞䈘⭫䈓ᴶ᯦ؗᚥރ䍯

...点) 4点4点无E5AR-TPR4DF 继电器输出 (开1点+关1点)+电流1点 10点*1 8点RS-485 E5AR-TPRQE3MF-FLK 关于带检验合格证型号 E5AR-K 安装对象型号 E5AR E53-COV14 型号 Y92S-L1 型号 Y92S-P4 型号 Y92H-9 ...

https://www.fa.omron.com.cn/data_pdf/cat/e5ar-t_e5er-t_ca_c_5_1.pdf

PDF1 400-820-4535 www.fa.omron.com.cn૞䈘⭫䈓ᴶ᯦ؗᚥރ䍯

...1点、关1点) 4点无DeviceNet E5AR-PR4F-DRT 继电器输出(开1点、关1点)+ 电流(传送)1点 E5AR-PRQ4F-DRT 关于带检验合格证型号 E5AR-K E5AR 8 400-820-4535 www.fa.omron.com.cn咨询电话最新信息免费电...

https://www.fa.omron.com.cn/data_pdf/cat/e5ar_e5er_ca_c_3_1.pdf

PDFLimit Controller E5CN-FR 1 Limit Controller

...voltage Power consumption 7.5 VA max. Sensor input Models with temperature inputs Thermocouple: K, J, T, E, L, U, N, R, S, or B Platinum resistance thermometer: Pt100 or JPt100 Infrared tempe...

https://www.fa.omron.com.cn/data_pdf/cat/e5cn-fr_h132-e1-01.pdf

PDF1 CSM_E5CS_DS_E_5_3 Temperature Controllers E5CS

...age Power consumption 100 to 240 VAC: 5 VA 24 VAC: 3 VA, 24 VDC: 2 W Sensor input Thermocouple: K, J, L Platinum resistance thermometer: Pt100, JPt100 Thermistor: E52-THE@@ Universal-input (t...

https://www.fa.omron.com.cn/data_pdf/cat/e5cs_ds_e_5_3_csm211.pdf

PDF操作简单,性能稳定 •视觉性高,微弱光线下可视性强 •更小尺寸,厚度仅为60mm

...电源电压的85%~110% 功率消耗 E5EC-PR-800在AC100~240V时最大6.6VA E5AC-PR-800在AC100~240V时最大7.0VA 传感器输入温度输入型热电偶:K、J、T、E、L、U、N、R、S、B、W或PL II 铂电阻:Pt100或JPt100 ...

https://www.fa.omron.com.cn/data_pdf/cat/e5ec_e5ac-pr-800_h07z-cn5-04.pdf

PDF模块型温控器E5ZN 商品选择⋯⋯⋯⋯⋯⋯⋯⋯210 共通注意事项⋯⋯⋯⋯⋯⋯236

...通注意事项⋯⋯⋯⋯⋯⋯236 技术指南⋯⋯⋯⋯⋯⋯⋯⋯481 用语说明⋯⋯⋯⋯⋯⋯⋯⋯485 相关信息 420 ⬉ᄤ⏽᥻఼ ଚક䗝ᢽ ݅䗮⊼ᛣџ乍 ⬉ᄤ⏽᥻఼ NEO ⬉ᄤ⏽᥻఼R ⬉ᄤ⏽᥻఼K ⬉ᄤ⏽᥻఼S 㒣⌢ൟ ῵ഫൟ Ⳍ݇䆒໛ 䕧ܹ䆒໛ ᡔᴃᣛफ ᪡԰㆛ PLCऩܗൟ ᬃᣕ䕃ӊ ⬉ᄤ⏽᥻఼Z 模块型温...

https://www.fa.omron.com.cn/data_pdf/cat/e5zn_ds_c_1_1.pdf

PDF1 CSM_E5ZN_DS_E_3_2 Modular Temperature Controller...

...er Models and Thermocouple Models The applicable standards for the input types are as follows: •K, J, T, E, N, R, S, B: JIS C1602-1995, IEC584-1 •L: Fe-CuNi, DIN 43710-1985 •U: Cu-CuNi, DIN 4...

https://www.fa.omron.com.cn/data_pdf/cat/e5zn_ds_e_3_2_csm218.pdf

PDFE5ZN Operation CSM_E5ZN_operation_TG_E_2_2

...ng Values Set values in each display can be changed by pressing the U and D Keys. Input type: 0 K thermocouple−200 to 1300°C Control method:ON/OFF control Alarm type: 2 upper limit Alarm valu...

https://www.fa.omron.com.cn/data_pdf/cat/e5zn_operation_tg_e_2_2_csm251.pdf

PDF1 400-820-4535 www.fa.omron.com.cn咨询电话最新信息电话

...则可能引发破损或起火。 J连接使用时,请务必连接同一电源,并同时接通电源。 使用不同电源会影响连接时的功能。 K最多连接台数会受到传感头电流消耗值等条件的影响。 连接的放大器台数请勿超过规格。 否则...

https://www.fa.omron.com.cn/data_pdf/cat/e9nc-aa_va_scea-cn5-194f.pdf

PDFSafety Light Curtain F3SG-R Series

...wall mounting bracket is not provided so that you can design your own wall mounting part. r p R k o l et u l ±15° ±22.5° F3SG-RA Multifunctional Advanced type * Image for illustration purpose...

https://www.fa.omron.com.cn/data_pdf/cat/f3sg-r_f094-e1_12_7_csm1040037.pdf

PDF图像处理外围设备样本

...5020□F FLV-BR21222□ H FLV-BR38037□ J FLV-BR6424UV L FLV-BR21230UV G FLV-BR21230□ I FLV-BR48031□ K FLV-BR11624UV B FLV-BR8532□ D FLV-BR14030□ (选装件安装螺丝孔) 长度0.8M 2-M1.4 2-M3插入极限5 5...

https://www.fa.omron.com.cn/data_pdf/cat/flv_fl_sdnb-cn5-029_6_9.pdf

PDF1 XC8 HM连接器(2mm间距Hard Metric连接器)

...插头(直型端子) XC8□-□□□1□-□□□ ①②③④⑤⑥⑦ ●XC8插座(L型端子) XC8□-□□□1 L -□□ ①②③④⑤⑥ ①系列内区分 A:A型插头 C:B型插头 E:C型插头 K:AB型插头 ②信号触头极数 ③电镀规格 1:Au ④端子形状 S:直型压配...

https://www.fa.omron.com.cn/data_pdf/cat/g135-cn1-05.pdf

PDF1 CSM_G3PC_DS_E_4_1 Solid State Relays with Failur...

... Temperature Input Voltage vs. Input Current Input Voltage vs. Input Impedance Input impedance (k Ω ) Input current (mA) Load current (A) Ta = +25°C Input impedance Input current Ambient temp...

https://www.fa.omron.com.cn/data_pdf/cat/g3pc_ds_e_4_1_csm173.pdf

PDFG5㌱ࡍ EtherCATሯᓊθཐ䖪᧝࡬ ㅜਾള䱻ᆿޞḽ߼ 儎䙕Ƚ儎㋴ᓜ

...䙕ᓜㅿ㓝Ⲻ2kHzȾٕࠣ䗴ࡦᵢޢਮԛᖶӝ૷Ⲻ2ك儎䙕θਥᴿ᭾㕟⸣᮪ᇐᰬ䰪Ƚᨆ儎༺⨼䙕ᓜȾ 䙐䗽儎䙕ौ㕟⸣㢸ᤃᰬ䰪 ᴶཝ䖢䙕6,000 r/min հᵃ⭫ᵰR88M-K-Z㌱ࡍ⭫ᵰਥᇔ⧦ᴶཝ䖢䙕6,000r/minⲺ儎䙕ौθԛ਀ਥ ᨆ儎༺⨼䙕ᓜⲺ儎䙕ᇐփȾ ࠰㢨Ⲻᇐփ㋴ᓜ 䞃༽儎࠼䗞⦽20bitⲺ໔䠅ශ㕌⸷ಞ ...

https://www.fa.omron.com.cn/data_pdf/cat/g5_series_i819-cn5_1_10.pdf

PDFCSM_G6B-4__ND_G3S4_DS_E_5_1 1 Terminal Relay/Termi...

...C max. 1 VDC min. 440Ω±20% 550Ω±20% 19.2 mA±20% 15.8 mA±20% 12 V 9.6 to 14.4 VDC 9.6 VDC max. 1 kΩ±20% 1.2 kΩ±20% 15.8 mA±20% 12.5 mA±20% 24 V 19.2 to 28.8 VDC 19.2 VDC max. 2.1...

https://www.fa.omron.com.cn/data_pdf/cat/g6b-4__nd_g3s4_ds_e_5_1_csm1057979.pdf

結果 7861 - 788021443

国/地域選択

Related Contents