IAグローバル検索 |
... max. 残留電圧:0.4V以下 (シンク電流35mA時) シンク電流:35mA max. 残留電圧:0.4V以下 (シンク電流35mA時) 20kHz 負論理 CW(シャフトから見て右回転)で出力コード増加コード引き出しタイプコネク...
https://www.fa.omron.com.cn/data_pdf/mnu/e6c3-a_inst-6903887-0h.pdf
...ARCH 9 20 22 READY 24 ORGSTP 19 OGND 21 25 T.COM 23 S.COM 6 RESET 5START 26 RUNON 28 ALM 27 INP CW limit in- put RUN command Alarm reset Origin proximity Start CCW limit input Origin search R...
https://www.fa.omron.com.cn/data_pdf/mnu/i524-04_fnd-x__x_-srt.pdf
...wed from the motor output shaft. (Standard setting) 1 Forward rotation is defined as clockwise (CW) rotation as viewed from the motor output shaft. (Reverse Rotation Mode) Position data from ...
https://www.fa.omron.com.cn/data_pdf/mnu/i538-e3-1_r88a-ncw152-drt.pdf
...nance. Compatible with Command Pulse of 90Phase Difference Inputs In addition to conventional CW/CCW inputs (2 pulse inputs) and SIGN/PULS inputs (1 pulse input), the SMARTSTEP 2 supports 9...
https://www.fa.omron.com.cn/data_pdf/mnu/i561-e1-08_r88m-g_r7d-bp.pdf
... output shaft is viewed from the end, counterclockwise (CCW) rotation is forward and clockwise (CW) rotation is reverse. Forward (CCW) Reverse (CW) 1-5 1-4 System Block Diagrams 1 Fe...
https://www.fa.omron.com.cn/data_pdf/mnu/i562-e1-09_r88m-g__r88d-gt_.pdf
... output shaft is viewed from the end, counterclockwise (CCW) rotation is forward and clockwise (CW) rotation is reverse. Forward (CCW) Reverse (CW) 1-5 1-4 System Block Diagrams 1 Fe...
https://www.fa.omron.com.cn/data_pdf/mnu/i566-e1-07_r88m-g_r88d-gn_-ml2.pdf
...ire input pins that are not being used. 2 kΩ 120Ω 20 kΩ 2kΩ 220Ω 5 2 6 Operation command 44 45 +CW −CW +CCW −CCW +CWLD −CWLD Reverse pulse Forward pulse BKIR Brake interlock Alarm ou...
https://www.fa.omron.com.cn/data_pdf/mnu/i571-e1-08_r88m-k_r88d-kt.pdf
...irection and the motor rotation direction. 0: A forward direction command sets the direction to CW as viewed from the shaft end. 1: A forward direction command sets the direction to CCW as vi...
https://www.fa.omron.com.cn/data_pdf/mnu/i572-e1-04_r88m-k__r88d-kn_-ml2.pdf
...e (Including CX-Drive) Support Software XW2B-80J7-12A Servo Relay Units (for FQM1)INCservo1ABS _CW-019Servo Drive Cable Servo Relay Unit XW2Z-J-B24 XW2-50G Terminal Block Conversion Units and...
https://www.fa.omron.com.cn/data_pdf/mnu/i584-e1-02_r88d-ke__r88m-kp_.pdf
...latform User's Manual (I681) Left Side Light Disc Right Side Light Disc State of Charge 0 to 90 cw 0 to 270 ccw 25% 0 to 180 cw 0 to 180 ccw 50% 0 to 270 cw 0 to 90 ccw 75% ...
https://www.fa.omron.com.cn/data_pdf/mnu/i681-e-02_md-650.pdf
...controller pulse output circuit Host controller specifications Maximum input frequency of drive CW (reverse) pulse input CCW (forward) pulse input Open collector 24 V power supply 200 kpps (m...
https://www.fa.omron.com.cn/data_pdf/mnu/i877-e1-01_gseries_to_g5series_replace.pdf
...osition control. SS2 series G5 series Terminal No. Symbol Name Terminal No. Symbol Name CN1 22 +CW/PULS/FA Reverse Pulses Input, Feed Pulses Input, or 90°Phase Difference Pulses (Phase A) CN1...
https://www.fa.omron.com.cn/data_pdf/mnu/i879-e1-01_smartstep2series_to_g5series.pdf
...n and Origin Shift.) H Backlash Compensation •Sets a difference between the detection angles in CW and CCW directions to absorb mechanical vibration. (Refer to 3-6-5 Backlash Compensation..) ...
https://www.fa.omron.com.cn/data_pdf/mnu/o008-e1-04_3f88l-160_162.pdf
...集电极均对应的位置指令脉冲的输入端子。 可通过指令脉冲输入选择(Pn005)的设定使之生效(设定值:0<出厂设定>)。 ○○ 3 +CW/ +puls/+FA 反转脉冲/进给脉冲/ 90°相位差信号 (A相) 4 -CW/ -pu...
https://www.fa.omron.com.cn/data_pdf/mnu/omnuc g5_sbce-cn5-357c.pdf
...的数据损坏参数损坏电源接通时从EEPROM读取数据时,确认写入EEPROM的数据损坏驱动禁止输入异常驱动禁止输入选择(Pn04)=0时,CW/CCW驱动禁止输入同为开放状态。 此外,驱动禁止输入选择(Pn04)=2时...
https://www.fa.omron.com.cn/data_pdf/mnu/omnuc g_sbce-cn5-353b.pdf
...准手册运动篇(SBCE-364)”中的 MC_GroupSyncMoveAbsolute(轴组周期同步绝对位置控制)指令。 6-6-3圆弧插补 6-6-4轴组周期同步位置控制 CW CCW CW:顺时针旋转 CCW:逆时针旋转 X坐标 Y坐标 6 - 57 ...
https://www.fa.omron.com.cn/data_pdf/mnu/sbca-cn5-449_nx1p2.pdf
...数据损坏 EEPROM校验码异常电源接通时从EEPROM读取数据时,确认写入EEPROM的数据损坏驱动禁止输入驱动禁止输入选择(Pn04)=0时,CW/CCW驱动禁止输入同为开放状态。 此外,驱动禁止输入选择(Pn04)...
...wn n: 0-255无Word WORD_DEVICE_FW FWn n: 0-9999无Word WORD_DEVICE_TW TWn n: 0-255无Word WORD_DEVICE_CW CWn n: 0-255无Word WORD_DEVICE_R Rn n: 0-255无Word WORD_DEVICE_TP TPn n: 0-255无Word WORD...
https://www.fa.omron.com.cn/data_pdf/mnu/v04z-cn-01_nt5z.pdf
...ays I/O status, present position, error code for each axis. Also switches between RUN and STOP, CW and CCW and sets override when the control flag (Enable button) is ON [Image] 1 2 3 4 5 6 7 ...
https://www.fa.omron.com.cn/data_pdf/mnu/v087-e1-01_ns5_ns8_ns10_ns12-v1_refer.pdf
...l system operation. Components Section 1–2 3 Indicators RUN: indicates operation is in progress CW: indicates controlled system (motor) is revolving clockwise CCW: indicates controlled system...
https://www.fa.omron.com.cn/data_pdf/mnu/w137-e1-04_c200h_nc111.pdf