| IAグローバル検索 |
...节。 输入传感器类型z可连接下列输入传感器,用于温度输入: 热电偶:K、J、T、E、L、U、N、R、S、B 非接触式温度传感器:ES1B 10~70°C、60~120°C、115~165°C、140~260°C 铂测温电阻体:Pt100、JPt100 模拟...
https://www.fa.omron.com.cn/data_pdf/mnu/h207-cn5-01_e5cz_e5cz-u_e5az_e5ez.pdf
... for temperature input: Thermocouple: K, J, T, E, L, U, N, R, S, B Infrared temperature sensor: ES1B 10 to 70°C 60 to 120°C, 115 to 165°C, 140 to 260°C Platinum resistance thermometer:Pt100, ...
https://www.fa.omron.com.cn/data_pdf/mnu/h207-e1-01_e5az_e5cz_e5cz-u_e5ez.pdf
...ֵ ᙃˈ䇋খ㾕ϝゴDŽ ٨䕧ܹӴᛳ఼㉏ ൟ zৃҹ䖲ϟ߫䕧ܹӴᛳ఼ˈ⫼Ѣ⏽ᑺ䕧ܹ˖ 䪖⬉䰏˖Pt100ˈJPt 100 ⛁⬉ي˖KˈJˈTˈEˈLˈUˈNˈRˈSˈB 䴲㾺ᓣ⏽ᑺӴᛳ఼㉏ൟES1B ˖10ć~70ćˈ60ć~120ćˈ115ć~165ćˈ140ć~260ć ᢳֵো䕧ܹ˖0̚50mV ٨ࠊ䕧ߎzḍE5AZ/E5EZⱘѻકൟোˈࠊ...
https://www.fa.omron.com.cn/data_pdf/mnu/oezml-050315-003_e5az_e5ez.pdf
...T-DEC 2021 Packing Label Control Components E5CSV OCT-DEC 2021 Packing Label Control Components ES1B JUL-SEP 2021 Packing Label Control Components H5AN OCT-DEC 2022 Packing Label Control Comp...
https://www.ia.omron.com/information/data_pdf/fy23-1q_ukca-for-gsite_20231013.pdf
...S, B, W, or PL II Platinum resistance thermometer: Pt100 or JPt100 Infrared temperature sensor (ES1B): 10 to 70°C, 60 to 120°C, 115 to 165°C, or 140 to 260°C Voltage input: 0 to 50 mV Models ...
https://www.omron-ap.co.in/data_pdf/cat/e5gn_ds_e_7_5_csm198.pdf
...85% to 110% of rated voltage Power consumption 5 W max. (at maximum load) Input * Thermocouple: ES1B Infrared Thermosensor: Analog input: Platinum resistance thermometer: Input impedance EJ1N...
https://www.omron-ap.co.in/data_pdf/cat/ej1_ds_e_12_5_csm222.pdf
...85% to 110% of rated voltage Power consumption 3 W max. (at maximum load) Input * Thermocouple: ES1B Infrared Thermosensor: Analog input: Platinum resistance thermometer: Input impedance EJ1N...
https://www.omron-ap.co.in/data_pdf/cat/ej1_h236-e1_4_1_csm1121137.pdf
...Infrared Thermosensor ES1B CSM_ES1B_DS_E_3_4 Achieve Low-cost Measurements with an Infrared Thermosensor. • The ES1B has an electromotive output as high as that of a thermoc...
https://www.omron-ap.co.in/data_pdf/cat/es1b_ds_e_3_4_csm229.pdf
...500 Analog input type N R S B W PL II 10 to 70°C Infrared Thermosensor 60 to 120°C 115 to 165°C ES1B 140 to 260°C 4 to 20mA Current input Use the following ranges for scaling: -1999 0 to 20mA...
https://www.omron-ap.co.in/data_pdf/mnu/e5ac-t_inst-2284568-8c.pdf
...W PL II 10~70°C 60~120°C 115~165°C 140~260°C 4~20 mA 0~20 mA 1~5 V 0~5 V 0~10 V 红外温度传感器 ES1B 电流输入电压输入 运行停止。 设定范围 设定 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16...
https://www.omron-ap.co.in/data_pdf/mnu/e5ac-t_inst-5377465-7a.pdf
...to 500 Analog input type N R S B W PL II 10 to 70℃ Infrared Thermosensor 60 to 120℃ 115 to 165℃ ES1B 140 to 260℃ 4 to 20mA Current input Use the following ranges for scaling: -1999 0 to 20mA ...
https://www.omron-ap.co.in/data_pdf/mnu/e5ac-t_inst-5377466-5a.pdf
...5 0 to 500 0 to 260 Analog input type 10 to 70°C Infrared Thermosensor 60 to 120°C 115 to 165°C ES1B 140 to 260°C 4 to 20mA Use the following ranges for scaling: -1999 Current input 0 to 20mA...
https://www.omron-ap.co.in/data_pdf/mnu/e5ac_inst-5377461-4a.pdf
...W PL II 10~70°C 60~120°C 115~165°C 140~260°C 4~20 mA 0~20 mA 1~5 V 0~5 V 0~10 V 红外温度传感器 ES1B 电流输入电压输入 °F -300~1500 -199.9~900.0 0.0~210.0 -199.9~900.0 0.0~210.0 -...
https://www.omron-ap.co.in/data_pdf/mnu/e5ac_inst-5377462-2a.pdf
...rature inputs J T Analog input type E L U N R S B W PL II 1WR& Infrared Thermosensor WR& WR& ES1B WR& 4 to 20mA &XUUHQWLQSXW 0 to 20mA 1 to 5V Voltage input 0 to 5V 0 to 10V 0 1 2 3 4 5 6...
https://www.omron-ap.co.in/data_pdf/mnu/e5cc-b_inst-3686270-4a.pdf
...alog input type E L U N R S B W PL II 10 to 70°C Infrared Thermosensor 60 to 120°C 115 to 165°C ES1B 140 to 260°C 4 to 20mA Current input 0 to 20mA 1 to 5V Voltage input 0 to 5V 0 to 10V 0 1 ...
https://www.omron-ap.co.in/data_pdf/mnu/e5cc-t_inst-3686265-8a.pdf
...Setting range Setting N R S B W PL II 10 to 70°C Infrared Thermosensor 60 to 120°C 115 to 165°C ES1B 140 to 260°C 4 to 20mA Current input 0 to 20mA 1 to 5V 0 to 5V Voltage input 0 to 10V 0 to...
https://www.omron-ap.co.in/data_pdf/mnu/e5cc-u_inst-3686278-0a.pdf
... 260 0 to 500 Setting N R S B W PL II 10 to 70°C Infrared Thermosensor 60 to 120°C 115 to 165°C ES1B 140 to 260°C 4 to 20mA Current input 0 to 20mA 1 to 5V Voltage input 0 to 5V 0 to 10V 0 1 ...
https://www.omron-ap.co.in/data_pdf/mnu/e5cc_inst-3686257-7a.pdf
...re inputs J T E L U N R S B C/W PL II 10 to 70°C Infrared Thermosensor 60 to 120°C 115 to 165°C ES1B 140 to 260°C 4 to 20mA Current input 0 to 20mA 1 to 5V Voltage input 0 to 5V 0 to 10V °C -...
https://www.omron-ap.co.in/data_pdf/mnu/e5cd(linearcurrentoutput)_inst-2899358-1a.pdf
...re inputs J T E L U N R S B C/W PL II 10 to 70°C Infrared Thermosensor 60 to 120°C 115 to 165°C ES1B 140 to 260°C 4 to 20mA Current input 0 to 20mA 1 to 5V Voltage input 0 to 5V 0 to 10V 0 1 ...
https://www.omron-ap.co.in/data_pdf/mnu/e5cd(voltageoutput_relayoutput)_inst-2890455-4a.pdf
...Њ3000 0Њ3200 0Њ3200 0Њ2300 0Њ190 0Њ240 0Њ320 0Њ500 ⁗ᤕ䠅䗉ޛ ㊱ශ N R S B C/W PL II 10Њ70°C 㓘ཌᓜ ՖಞES1B 60Њ120°C 115Њ165°C 140Њ260°C 4Њ20mA ⭫⍷䗉ޛ ሯ∊ׁ㕟᭴䟽⭞сࡍ㤹പφ-1999Њ9999Ƚ 0Њ20mA -199.9Њ9...
https://www.omron-ap.co.in/data_pdf/mnu/e5cd-8___inst-3105858-3b.pdf