PDFNX-series Digital I/O Unit NX-ID/IA/OD/OC/MD CSM_N...

...e XW2Z-ROC G7TC-ID16 Phillips screw F None XW2Z-ROC G7TC-IA16 Phillips screw F None XW2Z-ROC G70V-SID16P Push-in spring F None XW2Z-ROC G70V-SID16P-C16 Push-in spring F None XW2Z...

https://www.omron-ap.com/data_pdf/cat/nx-id_ia_od_oc_md_ds_e_9_1_csm1057421.pdf

PDFMachine Automation Controller NX-series

...C-ID16 XW2Z-RO£C PNP PNP NX-OD5121-5 Connection pattern Connection diagram G7TC-IA16 page A-146 G70V-SID16P --- G70V-SID16P-C16 --- G70V-SID16P-1 --- G70V-SID16P-1-...

https://www.omron-ap.com/data_pdf/mnu/w521-e1-13_nx-id_ia_oc_od_md.pdf

PDFCJ-series Input Units CJ1W-ID/IA CSM_CJ1W-ID_IA_DS...

...ting Horizontal Vertical Height (mm) (mm) (mm) DIN Screws Track NPN Push-In Plus terminal block G70V Inputs DC inputs PNP NPN NPN G70V-SID16P-1 *4 50 mA G70V-SID16P-C16 *5 2...

https://www.omron.co.id/data_pdf/cat/cj1w-id_ia_ds_e_11_13_csm1616.pdf

PDFCJ-series Mixed I/O Units CJ1W-MD CSM_CJ1W-MD_DS_E...

...ting Horizontal Vertical Height (mm) (mm) (mm) DIN Screws Track NPN Push-In Plus terminal block G70V Inputs DC inputs PNP NPN NPN G70V-SID16P-1 *4 50 mA G70V-SID16P-C16 *5 2...

https://www.omron.co.id/data_pdf/cat/cj1w-md_ds_e_9_13_csm1618.pdf

PDFCJ-series Output Units CJ1W-OC/OA/OD CSM_CJ1W-OUTP...

...ting Horizontal Vertical Height (mm) (mm) (mm) DIN Screws Track NPN Push-In Plus terminal block G70V Inputs DC inputs PNP NPN NPN G70V-SID16P-1 *4 50 mA G70V-SID16P-C16 *5 2...

https://www.omron.co.id/data_pdf/cat/cj1w-oc_oa_od_ds_e_8_14_csm1617.pdf

PDFTerminal Relay G6D-F4PU/G3DZ-F4PU (Push-In Plus Te...

...anel of each device, etc. Connector terminal box, etc. G2RV-ST G6D-F4PU 1 point 4 point G2RV-ST G70V 8 point 16 point Control box, etc. * Value Design for Panel Our shared concept “Value Desi...

https://www.omron.co.id/data_pdf/cat/g6d-f4pu_g3dz-f4pu_g6d-f4b_g3dz-f4b_j228-e1_1_9_csm1070913.pdf

PDFI/O Relay Terminal G70V I/O Relay Terminals with 1...

...I/O Relay Terminal G70V I/O Relay Terminals with 16 Points and Push-In Plus terminal blocks to Downsize Control Panels and Save Labor • I/O Relay Terminals with 16 points to mount G2RV Slim I...

https://www.omron.co.id/data_pdf/cat/g70v_j215-e1_2_19_csm1050154.pdf

PDFI/O Relay Terminal G7TC CSM_G7TC_DS_E_9_1

....omron.com/product/cautions/46/243/index.html. For PLC I/O unit connection procedures, refer to G70V/G7TC/G70A/G70D Table of I/O Relay Terminal and connectable device combinations (Cat. No. J...

https://www.omron.co.id/data_pdf/cat/g7tc_ds_e_9_1_csm1046354.pdf

PDFNX-series Digital I/O Unit NX-ID/IA/OD/OC/MD CSM_N...

...e XW2Z-ROC G7TC-ID16 Phillips screw F None XW2Z-ROC G7TC-IA16 Phillips screw F None XW2Z-ROC G70V-SID16P Push-in spring F None XW2Z-ROC G70V-SID16P-C16 Push-in spring F None XW2Z...

https://www.omron.co.id/data_pdf/cat/nx-id_ia_od_oc_md_ds_e_9_1_csm1057421.pdf

PDFMachine Automation Controller NX-series

...C-ID16 XW2Z-RO£C PNP PNP NX-OD5121-5 Connection pattern Connection diagram G7TC-IA16 page A-146 G70V-SID16P --- G70V-SID16P-C16 --- G70V-SID16P-1 --- G70V-SID16P-1-...

https://www.omron.co.id/data_pdf/mnu/w521-e1-13_nx-id_ia_oc_od_md.pdf

PDFCJ-series Input Units CJ1W-ID/IA CSM_CJ1W-ID_IA_DS...

...ting Horizontal Vertical Height (mm) (mm) (mm) DIN Screws Track NPN Push-In Plus terminal block G70V Inputs DC inputs PNP NPN NPN G70V-SID16P-1 *4 50 mA G70V-SID16P-C16 *5 2...

https://www.omron.com.au/data_pdf/cat/cj1w-id_ia_ds_e_11_13_csm1616.pdf

PDFCJ-series Mixed I/O Units CJ1W-MD CSM_CJ1W-MD_DS_E...

...ting Horizontal Vertical Height (mm) (mm) (mm) DIN Screws Track NPN Push-In Plus terminal block G70V Inputs DC inputs PNP NPN NPN G70V-SID16P-1 *4 50 mA G70V-SID16P-C16 *5 2...

https://www.omron.com.au/data_pdf/cat/cj1w-md_ds_e_9_13_csm1618.pdf

PDFCJ-series Output Units CJ1W-OC/OA/OD CSM_CJ1W-OUTP...

...ting Horizontal Vertical Height (mm) (mm) (mm) DIN Screws Track NPN Push-In Plus terminal block G70V Inputs DC inputs PNP NPN NPN G70V-SID16P-1 *4 50 mA G70V-SID16P-C16 *5 2...

https://www.omron.com.au/data_pdf/cat/cj1w-oc_oa_od_ds_e_8_14_csm1617.pdf

PDFTerminal Relay G6D-F4PU/G3DZ-F4PU (Push-In Plus Te...

...anel of each device, etc. Connector terminal box, etc. G2RV-ST G6D-F4PU 1 point 4 point G2RV-ST G70V 8 point 16 point Control box, etc. * Value Design for Panel Our shared concept “Value Desi...

https://www.omron.com.au/data_pdf/cat/g6d-f4pu_g3dz-f4pu_g6d-f4b_g3dz-f4b_j228-e1_1_9_csm1070913.pdf

PDFI/O Relay Terminal G70V I/O Relay Terminals with 1...

...I/O Relay Terminal G70V I/O Relay Terminals with 16 Points and Push-In Plus terminal blocks to Downsize Control Panels and Save Labor • I/O Relay Terminals with 16 points to mount G2RV Slim I...

https://www.omron.com.au/data_pdf/cat/g70v_j215-e1_2_19_csm1050154.pdf

PDFI/O Relay Terminal G7TC CSM_G7TC_DS_E_9_1

....omron.com/product/cautions/46/243/index.html. For PLC I/O unit connection procedures, refer to G70V/G7TC/G70A/G70D Table of I/O Relay Terminal and connectable device combinations (Cat. No. J...

https://www.omron.com.au/data_pdf/cat/g7tc_ds_e_9_1_csm1046354.pdf

PDFNX-series Digital I/O Unit NX-ID/IA/OD/OC/MD CSM_N...

...e XW2Z-ROC G7TC-ID16 Phillips screw F None XW2Z-ROC G7TC-IA16 Phillips screw F None XW2Z-ROC G70V-SID16P Push-in spring F None XW2Z-ROC G70V-SID16P-C16 Push-in spring F None XW2Z...

https://www.omron.com.au/data_pdf/cat/nx-id_ia_od_oc_md_ds_e_9_1_csm1057421.pdf

PDFMachine Automation Controller NX-series

...C-ID16 XW2Z-RO£C PNP PNP NX-OD5121-5 Connection pattern Connection diagram G7TC-IA16 page A-146 G70V-SID16P --- G70V-SID16P-C16 --- G70V-SID16P-1 --- G70V-SID16P-1-...

https://www.omron.com.au/data_pdf/mnu/w521-e1-13_nx-id_ia_oc_od_md.pdf

PDFCSM_CJ1W-ID_IA_DS_E_11_13 1 CJ-series Input Units ...

... voltage Horizontal (mm) Vertical (mm) Height (mm) DIN Track Screws Push-In Plus terminal block G70V Inputs DC inputs NPN 16 (SPSTNO×16) 50 mA 24 VDC 143 90 56 Yes Yes G70V-SID16P *4...

https://www.omron.com.tw/data_pdf/cat/cj1w-id_ia_ds_e_11_13_csm1616.pdf

PDFCSM_CJ1W-ID_IA_DS_TW_11_11 1 CJ系列輸入模組CJ1W-ID/IA

...號海外規格區別極性點數開閉部額定通電電流額定電壓寬 (mm) 長 (mm) 高 (mm) 鋁軌螺絲 Push-In Plus 端子台 G70V輸入用DC輸入 NPN 16點 (1a×16) 50mA DC24V 143 90 56○○ G70V-SID16P*3 U...

https://www.omron.com.tw/data_pdf/cat/cj1w-id_ia_ds_tw_11_11.pdf