... can be used only when PID control is selected. See whether you can change to PID control. K3HB-X A Process Indicator Ideal for Discriminating and Displaying Measurements for Voltage/Current ...
... Note: The gradient can be changed using either the internal or external gradient setting. K3HB-X A Process Indicator Ideal for Discriminating and Displaying Measurements for Voltage/Current ...
...band setting in heating and cooling control. Applicable models: E5CN, E5GN, E5EN, and E5AN K3HB-X A Process Indicator Ideal for Discriminating and Displaying Measurements for Voltage/Current ...
... mode in the Operating Level is set to STOP. Applicable models: E5CN, E5GN, E5EN, and E5AN K3HB-X A Process Indicator Ideal for Discriminating and Displaying Measurements for Voltage/Current ...
...larity between B and B. Make sure that the polarity and terminals are correctly connected. K3HB-X A Process Indicator Ideal for Discriminating and Displaying Measurements for Voltage/Current ...
...TOP settings to RUN. Outputs other than the control outputs (i.e., alarms) will be output. K3HB-X A Process Indicator Ideal for Discriminating and Displaying Measurements for Voltage/Current ...
...ck wires as compensating lead wires. Change the wiring location to shorten the lead wires. K3HB-X A Process Indicator Ideal for Discriminating and Displaying Measurements for Voltage/Current ...
...error to E5C2. Check the inputs if abnormal operation is detected. Applicable models: E5C2 K3HB-X A Process Indicator Ideal for Discriminating and Displaying Measurements for Voltage/Current ...
...J: 0 to 400.0 °C JPt100: 0 to 99.9 °C JPt100: 0 to 99.9 °C See note 3 Front panel dimensions 48 x 48 DIN size 48 x 48 DIN size External connections Plug-in (8-pin socket) Plug-in (8-...
...esistance and are the same length. Note:Extension lead wires are not available from OMRON. K3HB-X A Process Indicator Ideal for Discriminating and Displaying Measurements for Voltage/Current ...
...roller. Connectable Controllers E5CN-[]L Series: K3MA-J Series: K3GN-series: General-purpose 48 x 48-mm Temperature Controllers with PID control Process Meters with 14.2-mm character height, ...
...There are three wire from ES2-HB: white, red, and black. Typical Connection to Controllers K3HB-X A Process Indicator Ideal for Discriminating and Displaying Measurements for Voltage/Current ...
...in terminals. Be careful, because the terminal block model has different terminal numbers. K3HB-X A Process Indicator Ideal for Discriminating and Displaying Measurements for Voltage/Current ...
...5 A) S82K-00324 Switch Mode Power Supplies (Input: 100 to 240 VAC, Output: 24 VDC, 0.13 A) K3HB-X A Process Indicator Ideal for Discriminating and Displaying Measurements for Voltage/Current ...
...measure the temperature difference between two locations, use two isolated power supplies. K3HB-X A Process Indicator Ideal for Discriminating and Displaying Measurements for Voltage/Current ...
...sting conditions Power supply: 24 VDC Sensing object: Flat board (standard sensing object), 100 x 100 mm Fan: Industrial fan (50-cm diameter) strongest setting Testing equipment 24 VDC: KIKUS...
...km/h ±0.1 km/h = ±0.1 km/h. Consequently, the display may vary between 84.9 and 85.1 km/h. K3HB-X A Process Indicator Ideal for Discriminating and Displaying Measurements for Voltage/Current ...
...'s permissible load resistance > Digital Panel Meter's input resistance × Number of Meters K3HB-X A Process Indicator Ideal for Discriminating and Displaying Measurements for Voltage/Current ...
...A. The Shunt is a resistor that converts the DC current to a DC voltage. Setting Examples: K3HB-X A Process Indicator Ideal for Discriminating and Displaying Measurements for Voltage/Current ...
... the display is forcibly set to zero. First, restore the auto-zero time to its default setting (X = 9.9999, and Y = 10 E 9). If it is verified that measurements can be taken, set the auto-zer...