| IAグローバル検索 |
...制電源迴路 ・交流電源:額定電壓的1.15倍、3h、1次 ・直流電源:額定電壓的1.3倍、3h、1次 耐振動 誤動作 10~55Hz 重複振幅0.3mm X、Y、Z方向 各10min 耐久 10~25Hz 重複振幅2mm X、Y、Z方向 ...
https://www.omron.com.tw/products/family/843/specification.html
...8月26日 認證標準 UL (檔案No.E64562)、CSA (檔案No.LR35535) VDE (Certificate No.5915 、EN62314 (G3PA-2[]-VD (-X)) / No.6642、EN60947-4-3 (G3PA-4[]-VD)) 額定 輸入 (環境溫度25℃) 額...
https://www.omron.com.tw/products/family/987/specification.html
...s以上 协议 TCP/IP Mac版Master Agent 适用电脑 Apple产 eMac、iMac、Power Mac、Mac Pro、Xserve 适用OS与 适用平台 Mac OS X (v10.9.x) Mac OS X(v10.8.x)※3 Mac OS...
...中找出與範本最為近似的部分。由於是以關聯值表示相似的程度,故可檢查損傷或異種混入。且藉由輸出找到範本的位置(X,Y),亦可用來進行定位。 邊緣檢測 以濃度變化找出邊緣。設定「搜索邊緣的方向」與「色彩...
...位高低控制幫浦的ON、OFF (2電極式) 電極E1無接觸液面圖2中,電流流通的迴路(E1-E3間)為開路,電流無法流通。因此繼電器「X」不產生動作,繼電器「X」的接點仍「停留在b側」。 電極E1接觸液...
...01% F.S./°C Vibration resistance 0.35-mm single amplitude at 10 to 55 Hz for 50 min each in the X, Y, and Z directions Shock resistance 150 m/S 2 3 times each in 6 directions (up/down, left/r...
https://www.ia.omron.com/products/family/1424/specification.html
...ase Vibration resistance (destruction) 10 to 55 Hz with 1.5-mm double amplitude for 2 h each in X, Y, and Z directions Shock resistance (destruction) 500 m/s 2 , 3 times each in X, Y...
https://www.ia.omron.com/products/family/1457/specification.html
...e 10 to 150 Hz, 0.20-mm double amplitude, 15-m/s 2 acceleration with 10 sweeps of 8 min each in X, Y, and Z directions Shock resistance 150-m/s 2 acceleration for 3 times each in X, ...
https://www.ia.omron.com/products/family/1474/specification.html
...0 mm ±2 mm Beam shape Spot Line Beam size*1 50-μm dia. 100-μm dia. 300-μm dia. 75-μm dia. 75 μm x 2 mm 150 μm x 2 mm 450 μm x 2 mm 100 μm x 1.8 mm Resolution*2 2 μm...
https://www.ia.omron.com/products/family/1503/specification.html
...ibration resistance Frequency: 10 to 55 Hz; Acceleration: 50 m/s 2 , 10 sweeps of 5 min each in X, Y, and Z directions Shock resistance 150 m/s 2 (100 m/s 2 for relay outputs) 3 times each in...
https://www.ia.omron.com/products/family/1536/specification.html
...ibration resistance Frequency: 10 to 55 Hz; Acceleration: 50 m/s 2 , 10 sweeps of 5 min each in X, Y, and Z directions Shock resistance 150 m/s 2 (100 m/s 2 for relay outputs) 3 times each in...
https://www.ia.omron.com/products/family/1538/specification.html
...ibration resistance Frequency: 10 to 55 Hz; Acceleration: 50 m/s 2 , 10 sweeps of 5 min each in X, Y, and Z directions Shock resistance 150 m/s 2 (100 m/s 2 for relay outputs) 3 times each in...
https://www.ia.omron.com/products/family/1540/specification.html
...ibration resistance Frequency: 10 to 55 Hz; Acceleration: 50 m/s 2 , 10 sweeps of 5 min each in X, Y, and Z directions Shock resistance 150 m/s 2 (100 m/s 2 for relay outputs) 3 times each in...
https://www.ia.omron.com/products/family/1541/specification.html
... min Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions Shock resistance Destruction: 500 m/s 2 3 times each in X, Y, a...
https://www.ia.omron.com/products/family/1747/specification.html
... terminals of different polarity Vibration resistance 10 to 55 Hz, 20 m/s 2 for 2 hours each in X, Y, and Z directions Shock resistance 150 m/s 2 , 3 times each in 6 directions Weight 160 g D...
https://www.ia.omron.com/products/family/1757/specification.html
...AC, 50/60 Hz for 1 min Vibration resistance 10 to 55 Hz, 0.7-mm double amplitude 80 min each in X, Y, and Z directions Shock resistance 150 m/s2 3 times each in six directions (up/down, left/...
https://www.ia.omron.com/products/family/1830/specification.html
...e between the switch and actuator sensing surfaces. 2. The graph indicates shifting to X or Z direction from following condition that the switch and actuator target marks ...
https://www.ia.omron.com/products/family/1832/specification.html
...ength Sensor I/O Connector model Applicable Proximity Sensors Straight 2 m XS2F-E421-D80-E E2EH-X[]D[]-M1G E2EH-X[]B[]-M1 E2EH-X[]C[]-M1 5 m XS2F-E421-G80-E L-shape 2 m XS2F...
...ial Automation Features Lineup Specifications Dimensions Catalog last update: July 7, 2025 E2EH-X[]D[] DC 2-Wire Models Size M12 M18 M30 Shielded Shielded Model E2EH-X3D[] E2EH-X7D[] E2EH-X12...
https://www.ia.omron.com/products/family/1866/specification.html
...nce 10 to 150 Hz (acceleration 50 m/s 2 ) with a 0.35 mm single amplitude for 8 minutes each in X, Y, and Z directions, 10 times Shock resistance 150 m/s 2 in 6 directions (up/down, right/lef...
https://www.ia.omron.com/products/family/1876/specification.html