| IAグローバル検索 |
...lon Decimal symbol None, point (default), or comma Record separator None, comma, tab, space, or CR or CF+LF (default) •File logging cannot be used when performing continuous measurements. •If...
https://www.fa.omron.com.cn/data_pdf/mnu/z316-e1-02_fq-cr.pdf
...Y This is the Y coordinate of the position where the model was found. −99999.9999 to 99999.9999 CR Correlation This value indicates how similar the image is to the image registered as referen...
https://www.fa.omron.com.cn/data_pdf/mnu/z329-e1-02_fq-cr1_____-m.pdf
... setting) Stop bit 1 bit (Factory default setting) Header None (Factory default setting) Footer CR (Factory default setting) Reading valid time Trigger + 2 sec. (Factory default setting) Proc...
https://www.fa.omron.com.cn/data_pdf/mnu/z333-e1-04_v400-r2.pdf
...op Bit 1sbit* or 2 bits Header/Footer Prefix None*, 02
https://www.fa.omron.com.cn/data_pdf/mnu/z334-e1-03_v500-r2.pdf
...sults of position compensation processing. Applying the Results of Position Compensation: p.104 CR Correlation This is the correlation. 0 to 100 Parameter Setting Description Judgement -2: No...
https://www.fa.omron.com.cn/data_pdf/mnu/z337-e1-12_fq2-s_ch.pdf
...put. •Code Conversion The converted codes are outputted for the following character codes. Note CR Before conversion After conversion LF &h0D &h7F &h8541 DEL &h8543 Character code &h0A &hFF &...
https://www.fa.omron.com.cn/data_pdf/mnu/z338-e1-05_fq2-s_ch.pdf
...统用户手册第3章通信准备工作 ■未使用SECS时使用数据12345678测试1号节点。 •1:1协议 •1:N协议命令代码测试数据 CR 数据1数据2数据3数据4 10123456780Dh 响应代码测试数据 CR 数据1数据2数据3数据...
... with the data 12345678. •1:1 Protocol POWER OPERATING ALARMS BUSY ERROR Command code Test data CR Data 1 Data 2 Data 3 Data 4 10123456780Dh Response code Test data CR Data 1 Data 2 ...
https://www.fa.omron.com.cn/data_pdf/mnu/z360-e1-05_v640-ham11-v4_-l-v2.pdf
... 93. A test is preformed for the Amplifier Unit using the data 12345678. Command code Test data CR Data 1 Data 2 Data 3 Data 4 10123456780Dh Response code Test data CR Data 1 Data 2 ...
https://www.fa.omron.com.cn/data_pdf/mnu/z361-e1-08_v640-ham11(-l)-etn-v2.pdf
...d [ZEROSP] Off* /On− Field separator [FIELD] None [NO]*/Comma [COMMA]/ Tab [TAB]/Space [SPACE]/ CR[CR]/LF[LF]/CR+LF[CRLF]/ Semicolon [SEMICO] − Record separator [RECORD] Non...
https://www.fa.omron.com.cn/data_pdf/mnu/z362-e1-09_zw-_000.pdf
...Stop bit Sets the stop bit. 1bit (default), 2bit Delimiter Sets the delimiter (data delimiter). CR (default), LF, CR+LF CS/RS Sets the flow control. OFF(default value)/ON •With the Z...
https://www.fa.omron.com.cn/data_pdf/mnu/z363-e1-07_zw-_000.pdf
...nclude a line feed code in a string Parameter to be adjusted Troubleshooting Macro code Add (+) CR→Chr$(13) LF→Chr$(10) to the string. 3 Screen Component and Setting Configuration 3-11 FH Ser...
...communications.
https://www.fa.omron.com.cn/data_pdf/mnu/z392-e1-08_v430-f.pdf
...ir wires for pilot lamps (and particularly lamps with filaments). •Use countermeasures, such as CR surge absorbers and diodes, for input device and output load device noise sources, as requir...
https://www.fa.omron.com.cn/data_pdf/mnu/z400-e1-09_gi-s.pdf
...imal value as a parameter, add lowercase h immediately after the K command. For example, to set CR (hexadecimal value: 0D) to the footer (postamble), you can enter it as follows. ...
https://www.fa.omron.com.cn/data_pdf/mnu/z407-e1-06_v3_0-f_v4_0-f.pdf
...on the command, refer to 9.2.2. Command Settings. Response Format 1 2 3 4 5 6 7 8 9 0 A B C D E CR LF Read data Footer 8. Initializing the System 26 8. Initializing the System This document a...
https://www.fa.omron.com.cn/data_pdf/mnu/z412-e1-01_v330-f_v430-f.pdf
...00 bps Protocol macro transmission method Full-duplex --- Header --- None (default) Footer --- <CR...
https://www.fa.omron.com.cn/data_pdf/mnu/z414-e1-01_v320-f_v420-f_v430-f.pdf
..., and output information, are delimited with semicolons. At the end of the record, a line feed (CR+LF) is entered. (Execution date and time); (user name); (input information); (output informa...
...devices. Timeout [s] 1 to 120 [5] Set the time in which a timeout error will occur. Delimiter •[CR] •LF •CR+LF Use the same communications specifications as the external device. Sett...
...operate, and then click the button. Parameter to be adjusted Troubleshooting Macro code Add (+) CR→Chr$(13) LF→Chr$(10) to the string. Parameter to be adjusted Troubleshooting Enabled/disable...