PDFCat. No. W472-E1-16 SYSMAC CJ Series

...nverters. Example: NS-series PT Serial Option Boards CP1W-CIF01 CJ2M-CPU3@ CP1W-CIF12 COMM COMM RDA- RDB+ SDA- SDB+ FG CP1W-CIF11 COMM RDA- RDB+ SDA- SDB+ FG RS-232C NT Link or other...

https://www.omron-ap.com/data_pdf/mnu/w472-e1-16_cj2h-cpu6_eip_cj2m-cpu.pdf

PDFCat. No. W472-E1-16 SYSMAC CJ Series

...nverters. Example: NS-series PT Serial Option Boards CP1W-CIF01 CJ2M-CPU3@ CP1W-CIF12 COMM COMM RDA- RDB+ SDA- SDB+ FG CP1W-CIF11 COMM RDA- RDB+ SDA- SDB+ FG RS-232C NT Link or other...

https://www.omron.co.id/data_pdf/mnu/w472-e1-16_cj2h-cpu6_eip_cj2m-cpu.pdf

PDFCat. No. W472-E1-16 SYSMAC CJ Series

...nverters. Example: NS-series PT Serial Option Boards CP1W-CIF01 CJ2M-CPU3@ CP1W-CIF12 COMM COMM RDA- RDB+ SDA- SDB+ FG CP1W-CIF11 COMM RDA- RDB+ SDA- SDB+ FG RS-232C NT Link or other...

https://www.omron.com.au/data_pdf/mnu/w472-e1-16_cj2h-cpu6_eip_cj2m-cpu.pdf

PDFE 5 CN - H T E 5 CN - H E 5 AN E

...請參閱(第81頁) SSR輸出*3 AC75~250V 1A (電阻負載) 位置比例型繼電器輸出 AC250V 1A (包含浪湧電流) 電位計規格 RDB RDA SG SDB SDA 1 2 3 4 5 6 7 8 9 10 21 22 23 24 25 26 27 28 29 30 11 12 1...

https://www.omron.com.tw/data_pdf/cat/e5_n_e5_n-h_e5_n-ht_sgtd-054_tw_9_4.pdf

PDF数字式控制器 通信手册 E5□C H181-CN5-10 通信数据

...时接收)有RS控制RD的有无RS控制的选择 6无RS控制(常时发送)有RS控制SD的有无RS控制的选择 6-5-3 PLC的设定 RDA- RDB+ SDA- SDB+ FG FG RDA- RDB+ 屏蔽线屏蔽线屏蔽线 13 14 E5CC No.0 E5CC No.1 E...

https://www.omron.com.tw/data_pdf/mnu/h181-cn5-10.pdf

PDF通訊/連結/指令 中文技術手冊

...後拆除標籤,以確保具有適當的散熱。 讓標籤黏貼可能會導致故障。 ‧在將RS-422A/485連接插頭接線前,應檢查極性。 SDA/B與RDA/ B訊號的腳位會因一些外部裝置而不同。 ‧於開始操作前,檢查並確認RS-422A/485...

https://www.omron.com.tw/data_pdf/mnu/ote-plc-01n_cs1_cj1.pdf

PDFUSER’S MANUAL Cat. No. W472-E1-16

...the CP1W-CIF12 and CP1W-CIF12-V1 Option Boards. Add a Serial Option Board (CJ2M-CPU3Only) COMM RDA- RDB+ SDA- SDB+ FG COMM RDA- RDB+ SDA- SDB+ FG COMM RS-232C CJ2M-CPU3@ CP1W-CIF01 ...

https://www.omron.com.tw/data_pdf/mnu/w472-e1-16_cj2h-cpu6_eip_cj2m-cpu.pdf

PDFCat. No. W472-E1-16 SYSMAC CJ Series

...nverters. Example: NS-series PT Serial Option Boards CP1W-CIF01 CJ2M-CPU3@ CP1W-CIF12 COMM COMM RDA- RDB+ SDA- SDB+ FG CP1W-CIF11 COMM RDA- RDB+ SDA- SDB+ FG RS-232C NT Link or other...

https://www.omron.com.vn/data_pdf/mnu/w472-e1-16_cj2h-cpu6_eip_cj2m-cpu.pdf

PDF[W356-E1-08] CPM2C Programmable Controller Operati...

...Temperature Controllers and Digital Panel Meters. RS-422 Pin Assignments RS-485 Pin Assignments RDARDA− Transmit/receive data (I/O) Receive data (input) RDB+ RDB+ SDA− SDA− Transmi...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w356-e1-08_cpm2c.pdf

PDF[N096-E1-01] K3NX, K3NV, K3NH, K3NR, K3NP, K3NC Co...

...inator Processor Abbreviation RS-422 FG The terminator must have a minimum resistance of 100 Ω. RDA 9 SDA RDB 5 SDB SDA 6 RSA SDB 1 RSB SG 3 SG SN751177N or equivalent Terminal 220 Ω block sw...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/n096-01_k3nx_k3nv_k3nh_k3nr_k3np_k3nc.pdf

PDF[SCEI-708A] K3N□ 通信出力タイプ 操作マニュアル

...は、合計で最大500mです。 ・ケーブルには、シールド付ツイストペア線(AWG28以上)をご使用ください。 終端抵抗 略称 FG RDA RDB SDA SDB SG 終端抵抗 (ターミネータ) ターミネータは合成して 100Ω以上...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/scei-708a_k3n_com.pdf

PDFCPM2C Programmable Controllers

...es. •Always check polarity before wiring RS-422A/485 connectors. The polarity for the SDA/B and RDA/B signals can be different for some external devices. •Check to be sure that terminating re...

https://www.fa.omron.com.cn/data_pdf/closed/mnu/cpm2c(safetyprecautions)_inst-2139713-4c.pdf

PDFCat. No. N96-E1-1 Communication Output-type

... computer Abbrevi- ation Terminator The terminator must have a mini- mum resistance of 100Ω. FG RDA RDB SDA SDB SG 9 5 6 1 3 Abbrevi- ation Pin No. SDA SDB RSA RSB SG Shielded cable Processor...

https://www.fa.omron.com.cn/data_pdf/closed/mnu/n096-01_k3nx_k3nv_k3nh_k3nr_k3np_k3nc.pdf

NX1P2 NX-series NX1P2 CPU Units/Specifications | O...

...ock Abbreviation Four-wire type selected Two-wire type selected Signal name I/O Signal name I/O RDA- Reception data - Input Communication data - I/O * RDB+ Reception data + Communication data...

https://www.ia.omron.com/products/family/3650/specification.html

PDFデジタルロードセルメータ 形K3NV 生産終了のお知らせ

...2 H COM C3 C3 通信出力 (RS422+NPNオープンコレクタ HH/H/PASS/L/LL) 出力 NPNトランジスタ (DC 12∼24V 50mA max.) RS-422 RDA TERMINATER ON OFF SDA L LL 6 7 8 9 1 2 3 4 5 6 7 8 9 1 2 3 4 5 RDB...

https://www.fa.omron.co.jp/data_pdf/closed/prdn_2004043-2_1.pdf

PDF[H186-E1-06] E5[]C-T (Programmable Type) Digital T...

... available USB cable E5CC-T No.0 PORT1 FG L1 E5CC-T No.1 E5CC-T No.2 SDA- SDB+ AC100-240V INPUT RDA- RDB+ L2/N Peripheral (USB) port C PORT2 RUN OUTPUT AC240V DC24V 25 0 C 25 0 C 25 0 The app...

https://www.fa.omron.co.jp/data_pdf/mnu/h186-e1-06_e5_c-t.pdf

PDF[P520-E1-02] E5[]D, E5[]C, E5[]C-T Digital Temprat...

...2) applicable connector: Terminal block Pin No. Symbol Signal name Input/Output 1 (See note 1.) RDA Receive data - Input 2 (See note 1.) RDB Receive data + Input 3 (See note 1.) SDA Send data...

https://www.fa.omron.co.jp/data_pdf/mnu/p520-e1-02_e5_d_e5_c_e5_c-t.pdf

PDF[SGTD-743E] E5□C-T デジタル調節計(プログラムタイプ) 通信マニュアル

...1 ABC 市販の USBケーブル 形E5CC-T No.0 PORT1 FG L1 SDA- SDB+ AC100-240V INPUT 形E5CC-T No.1 形E5CC-T No.2 RDA- RDB+ L2/N ぺリフェラル(USB) ポート C PORT2 RUN OUTPUT AC240V DC24V 25 0 C 25 0 C...

https://www.fa.omron.co.jp/data_pdf/mnu/sgtd-743e_e5_c-t.pdf

PDF[W375-E1-05] CS1W-LC001 Loop Control Unit (Ver.2.5...

...1-4: ON (2-wire, RS-485) ES100X (unit No. 0) RS-485 Signal Pin No. GRD 1 SG 2 SDB 3 SDA 4 RDB 5 RDA 6 Terminal block ・ RS-485 Signal SG RDBRDA+ Terminal 15 17 16 Terminal block Shield ES100X...

https://www.fa.omron.co.jp/data_pdf/mnu/w375-e1-05_cs1w-lc001.pdf

生産終了品一覧 - 生産終了品/推奨代替品 | オムロン制御機器