Primary Contents

IAグローバル検索結果

国/地域選択

IAグローバル検索
結果 9981 - 1000021444
PDF[9531919-4D] V780-HMD68-ETN-JP 920MHz帯 移動体識別用無線設備 ...

...ド Frame ground ― ・推奨イーサネットケーブル(最大 100m)/ Recommended Ethernet Cable (100 m max.) 形XS5W-T42□-□ME-K(OMRON製/made by OMRON) I/O ― IN ― ― 0V ― ・推奨電源ケーブル(最大 60m)/...

https://www.fa.omron.co.jp/data_pdf/mnu/v780-hmd68-etn-jp_inst-9531919-4d.pdf

PDF[W153-E1-04] C200H-IDS01-V1/IDS21 ID Sensor Operat...

...arrier’s data. The details of the commands are as follows: Function Checking of data Command MD-K MD-C Checking of the number of overwriting operations MD-L MD-S Meaning By adding a check cod...

https://www.fa.omron.co.jp/data_pdf/mnu/w153-e1-04_c200h-ids.pdf

PDF[W165-E1-04] C200H-ASC02 ASCII Unit Operation Manu...

...or parameter definitions, refer to Appendix C. Examples: PC WRITE “H4, A2, I3, O4”; 1234, “AB”, K, L Remarks: If the data of the previous PC WRITE statement has not been read by the PC, the n...

https://www.fa.omron.co.jp/data_pdf/mnu/w165-e1-04_c200h_asc02.pdf

PDF[W174-E1-07] C1000H-SLK11/SLK21-V1, C200HW-SLK13/S...

...y size Kind of file memory Meaning Unit Program area size The size of PC Setup and program area K words (1K words = 1,024 words) No. of DM words Total words in the DM area Words EM bank numbe...

https://www.fa.omron.co.jp/data_pdf/mnu/w174-e1-07_c200hw_slk___c1000h_slk__-v1.pdf

PDF[W225-E1-05] C200H-TC001/TC002/TC003/TC101/TC102/T...

... type setting 8 7 9 01 2 3 6 5 4 C200H-TC00@ Setting 0 1 2 3 4 5 6 7 8 9 Sensor type R S K J T E B N L U The switch is factory-set to 2. The selected position is shown by the arrow. Turn the ...

https://www.fa.omron.co.jp/data_pdf/mnu/w225-e1-05_c200h-tc.pdf

PDFCat. No. W267-E1-13 DeviceNet™ OPERATION MANUAL

... 0 to 10 V, –10 to 10 V Outputs: 0 to 5 V, 1 to 5 V, 0 to 10 V, –10 to 10 V Sensor types: R, S, K, J, T, B, L Sensor types: Pt100, JPt100 1 external input 2 external outputs Note The Analog I...

https://www.fa.omron.co.jp/data_pdf/mnu/w267-e1-13_devicenet.pdf

PDF[W303-E1-09] C200HX, C200HG, C200HE Programmable C...

...t possible unless memory is cleared first. 2. The expansion DM area can be set to 0, 1, 2, or 3 K words. The following key sequence creates a 2-KW expansion DM area (DM 7000 to DM 8999). CLR ...

https://www.fa.omron.co.jp/data_pdf/mnu/w303-e1-09_c200hx_hg_he_ope.pdf

PDF[W304-E1-05] C200HW-COM01/COM02-V1 to C200HW-COM06...

...xii xiii xiii 1 2 14 16 19 23 24 34 38 55 Appendices: System Protocols A B C D E F G H I J K L E5K Digital Controller Read Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....

https://www.fa.omron.co.jp/data_pdf/mnu/w304-e1-05_c200hw_com01_com02_v1-06_v1.pdf

PDF[W314-E1-01] C200H-MC221 Motion Control Unit Opera...

...Model 1, 2, 3... 1. Turn on the power supply to the computer, and start up the MCSS. 2. Select “K:MC Models” from the System Setting Menu. MC model ...

https://www.fa.omron.co.jp/data_pdf/mnu/w314-e1-01_c200h-mc221.pdf

PDF[W315-E1-03] C200H-MC221 Motion Control Unit Opera...

...ponse time 1 ms max. OFF response time 2.5 ms max. Circuit Configuration +24 V 24 VDC 680 Ω 5 6 kΩ 5.6 Photocoupler The circuit in the table below is used to interface outputs RUN (X and Y) a...

https://www.fa.omron.co.jp/data_pdf/mnu/w315-e1-03_c200h-mc221.pdf

PDF[W325-E1-04] C200H-AD003/DA003/DA004/MAD01 Analog ...

...e Number of Analog I/O Units that can be mounted on the same Rack Rack model C200HX/HG/HE CPU R k or I/O E Rack Expansion i Rack C200HS CPU Rack,, I/O E Expansion i R Rack, k or Remo...

https://www.fa.omron.co.jp/data_pdf/mnu/w325-e1-04_c200h-ad003_da003_004_mad01.pdf

PDF[W334-E1-04] C200HW-NC113/NC213/NC413 Position Con...

...acity Leakage current 30 mA at 4.75 to 26.4 VDC (NPN open collector) (16 mA: Terminals with 1.6-kΩ limit resistance) 7 mA at 4.75 to 26.4 VDC (NPN open collector) Residual voltage 0.6 V max. ...

https://www.fa.omron.co.jp/data_pdf/mnu/w334-e1-04_c200hw-nc.pdf

PDF[W341-E1-05] CQM1(H)-PRO01-E, C200H-PRO27-E Progra...

...M1H-PRO01-E LCD display Mode switch FUN SFT A ST OR H AA LD AC OUT N M 7 0 . −IR TR J *EM WR/LR K AR HR EM DM P CH *DM Q CONT # R 6 T DEL MON 2 3 Y TEXT ! CLR VRFY NOT B C CHG W INS TN AND G ...

https://www.fa.omron.co.jp/data_pdf/mnu/w341-e1-05_c200h_cqm1_pro.pdf

PDF[W343-E1-07] CS1W-ETN01/ETN11, CJ1W-ETN11 Ethernet...

... power supply Noise filter As close as possible Recommended filter: MAS-1206-33 by Nemic-Rambda K.K. Power Supply Specifications Specifications Rated voltage: 250 V (AC, DC) Rated cu...

https://www.fa.omron.co.jp/data_pdf/mnu/w343-e1-07_cs1w_cj1w-etn.pdf

PDF[W366-E1-16] CXONE-AL[][]D-V4 CX-Simulator Ver. 2....

...-OD291 4 Units 96-point Input Unit CS1W-ID291 4 Units 96-point Output Unit CS1W-OD291 4 Units 5 k steps LD 2.5 k steps, OUT 2.5 k steps None CS/CJ-series Expansion Rack (for...

https://www.fa.omron.co.jp/data_pdf/mnu/w366-e1-16_cx-simulator.pdf

PDF[W376-E1-08] CS1W-NC113/NC213/NC413/NC133/NC233/NC...

...or (NPN-output model). A14 Signal Input common PK564AW stepping motor – CW CCW output (with 1.6-k A8 resistance) 24-V power supply for output A1 Origin Input signal Example: DFU1514W stepping...

https://www.fa.omron.co.jp/data_pdf/mnu/w376-e1-08_cs1w_nc.pdf

PDF[W377-E1-04] CPM2C-S100C(-DRT)/S110C(-DRT) Program...

...2 input points on each Temperature Sensor Unit. • Thermocouple inputs (and measurement ranges): K (–200 to 1,300°C), K (0.0 to 500.0°C), J (-100 to 850°C), and J (0.0 to 400.0°C). • ...

https://www.fa.omron.co.jp/data_pdf/mnu/w377-e1-04_cpm2c_s.pdf

PDF[W378-E1-02] CS1W-HIO01-V1/HCP22-V1/HCA[]2-V1 Cust...

... 1 ms max. Circuit configuration Customizable Counter Unit Input indicator Interrupt inputs 4.7 kΩ 750 Ω Internal circuit Input indicator Normal inputs 4.7 kΩ 750 Ω Internal circuit ...

https://www.fa.omron.co.jp/data_pdf/mnu/w378-e1-02_cs1w-hio_hcp_hca_v1.pdf

PDF[W396-E1-03] CJ1W-TC[][][] Temperature Control Uni...

...ut detection function. Each of these has one model that is compatible with thermocouples (R, S, K, J, T, B, or L) and another model that is compatible with platinum resistance thermometers (J...

https://www.fa.omron.co.jp/data_pdf/mnu/w396-e1-03_cj1w_tc.pdf

PDF[W410-E1-01] CS1W-GPI01 GP-IB Interface Unit Opera...

...is sent to the GP-IB bus. • Leftmost byte first (leftmost → rightmost) Word in PLC Bits 8 to 15 K Byte 1 K+1 Byte 3 : Bits 0 to 7 Byte 2 Byte 4 : : • Rightmost byte first (rightmost ...

https://www.fa.omron.co.jp/data_pdf/mnu/w410-e1-01_cs1w_gpi01.pdf