IAグローバル検索 |
...lies and output power supplies for the NXR-series products. We recommend that you use the OMRON S8VK-S-series Power Supplies. EMC standard compliance was confirmed for the recommended Power S...
https://www.omron-ap.co.nz/data_pdf/mnu/w640-e1-01_nxr-ilm08c-ect.pdf
...urrent, which has a rating of 4.2A max." (24 VDC power supply). Recommended power supply: OMRON S8VK-S (30 W or 60 W) These products are UL-Listed (UL 508, class 2 power supply), CE marking c...
https://www.omron-ap.co.nz/data_pdf/mnu/z405-e1-07_f3sg-sr_pg.pdf
...plies and output power supplies for the ZP-series products. We recommend that you use the OMRON S8VK-S/S8VK-G-series Power Supplies. EMC standard compliance was confirmed for the recommended ...
...plies and output power supplies for the ZP-series products. We recommend that you use the OMRON S8VK-S/S8VK-G-series Power Supplies. EMC standard compliance was confirmed for the recommended ...
https://www.omron-ap.co.nz/data_pdf/mnu/z496-e1-01_zp-eip.pdf
...rightness control NYM1@W-C10@@ Power Supply Output voltage: 24 VDC Push-In Plus terminal blocks S8VK-S@@@24 UPS *2 Output voltage during backup operation: 24 VDC ± 5% S8BA UPS Communication C...
https://www.omron-ap.co.th/data_pdf/cat/nx_ny_ai_controller_ds_e_4_6_csm1066041.pdf
...S07 NY000-AT01 NY000-AT02 NY000-AC00 2M NY000-AC00 5M NYM1@W-C1@@@ S8VK-G@@@24 S8VK-X@@@24A-EIP S8VK-S@@@24 S8VK-WA@@@24 S8BA 5 NY5@@-1 Product name Specifications Cable length: 2 m Signals f...
https://www.omron-ap.co.th/data_pdf/cat/ny5__-1_ds_e_5_7_csm1054878.pdf
...Monitor Link * Industrial Monitor Software (eg. brightness control, control setting, etc.) (eg. S8VK-S) (eg. S8BA) DVI or DisplayPort++ (eg. NJ, NX, CP, CJ, CS-series) KEYBOARD TOUCHSCREEN In...
https://www.omron-ap.co.th/data_pdf/cat/nyb_ds_e_6_2_csm1054446.pdf
...n Plus terminal blocks Power Supply USB Type-A to USB Type-B Cables DVI Cables Model VESA mount S8VK-S@@@24 Cable length: 2 m USB 2.0 Minimum bend radius: 25 mm FH-VUAB 2M Cable length: 5 m U...
https://www.omron-ap.co.th/data_pdf/cat/nym_ds_e_5_3_csm1054877.pdf
...Monitor Link * Industrial Monitor Software (eg. brightness control, control setting, etc.) (eg. S8VK-S) (eg. S8BA) DVI or DisplayPort++ KEYBOARD TOUCHSCREEN Industrial PC software (eg. PC sup...
https://www.omron-ap.co.th/data_pdf/cat/nyp_ds_e_7_2_csm1054447.pdf
...ium-ion Batteries *4 Life Expectancy: 10 yrs. *5 (replaceable battery) Switch Mode Power Supply S8VK-S (120 W) 100mm Plug-in Terminal Block Just press bar terminals in for easy wiring Connect...
https://www.omron-ap.co.th/data_pdf/cat/s8ba_u700-e1_2_4_csm1042404.pdf
...ng Power supplies and associated equipment 32 mm 55 mm 55 mm 55 mm 32 mm 45 mm 90 mm 60 W 120 W S8VK-S 38 mm 90 W 120 W S8VK-X Noise filter S8V-NF DC electronic circuit protector S8V-CP 60 mm...
https://www.omron-ap.co.th/data_pdf/cat/s8v-cp_t227-e1_2_1_csm1074606.pdf
...ct Lineup/Main Specifications S8V-NFS203 (3 A) S8V-NFS206 (6 A) [Recommended products] S8VK-X / S8VK-S / S8VK-G * Also applicable to other power supplies. Basic specifications Attenuation...
https://www.omron-ap.co.th/data_pdf/cat/s8v-nfs20__t214-e1_1_3_csm1060638.pdf
...tion). Two S8VK-G units cannot be mounted together in a contact mounting. Combinations with the S8VK-S Model number *1 For backup operation S8VK-R10 S8VK-R10 - S8VK-R20 S8VK-S12024 S8VK-S2402...
https://www.omron-ap.co.th/data_pdf/cat/s8vk-r_t059-e1_4_8_csm1013796.pdf
...Switch Mode Power Supply S8VK-S (30/60/120/240/480-W Models) A Perfect Fit for Small Control Panels Coated PCBs for Better Resistance to Environment Connections for Easy Wiring • Operation po...
https://www.omron-ap.co.th/data_pdf/cat/s8vk-s_t205-e1_2_1_csm1050136.pdf
...T42 - ME-K (recommended) Power cable *2 XS5F-D42 - 80-F (recommended) The photo above is of the S8VK-S. □□ □□ *1. The maximum extension length of the Ethernet cable is 100 m. PC *2. The maxim...
https://www.omron-ap.co.th/data_pdf/cat/v780_q256-e1_1_13_csm1054509.pdf
...d Power Supplies for a CPU Rack with an NX-series CPU Unit. We recommend that you use the OMRON S8VK-S Series Power Supplies to connect an Advanced Temperature Control Unit on a Slave Termina...
https://www.omron-ap.co.th/data_pdf/mnu/h238-e1-01_nx-htc____.pdf
...o reduce interference. We have confirmed that this product conforms to EMC standards with OMRON S8VK-S series Power Supplies. Applicable wire size for Unit power source and IO power source te...
https://www.omron-ap.co.th/data_pdf/mnu/nx-had401_had402(safetyprecautions)_inst-5377009-0b.pdf
...o reduce interference. We have confirmed that this product conforms to EMC standards with OMRON S8VK-S series Power Supplies. Note: When complying with EMC standards, both the line connecting...
...o reduce interference. We have confirmed that this product conforms to EMC standards with OMRON S8VK-S series Power Supplies. For KC standard only ● 사 용 자 안 내 문이 기기는 업무용 환경에서...
...o reduce interference. We have confirmed that this product conforms to EMC standards with OMRON S8VK-S series Power Supplies. Conformance to KC Standards ● 사 용 자 안 내 문이 기기는 업무용 ...