Primary Contents

IAグローバル検索結果

国/地域選択

IAグローバル検索
結果 1121 - 11402042
PDFSmart Camera FQ2-S/CH Series User's Manual

... Manual Function List The following functions can be used in calculations. Function Description COS Finds the cosine. The result is a value between 1 and 1. The angle in the expression is in...

https://www.omron-ap.co.in/data_pdf/mnu/z337-e1-12_fq2-s_ch.pdf

PDFVision Sensor FH Series Vision System

...itModel Copies the model data of aprocessing unit. Processing unit control - OK OK OK page 8-60 Cos Gets the cosine of the specifiedexpression. Arithmetic calculation OK OK OK OK page 8-61 Cr...

https://www.omron-ap.co.in/data_pdf/mnu/z367-e1-14_fh.pdf

PDFEtherNet/IPTM Safety I/O Terminal

...mp Status TO7 Muting Lamp Status TO3 Global Safety Input Status CIS Global Safety Output Status COS Input Power Error UB Output Power Error UL Safety Inputs Safety Input Status Bit 10 Safety ...

https://www.omron-ap.co.in/data_pdf/mnu/z400-e1-09_gi-s.pdf

PDFMiniature Power Relays MY-GS CSM_MY-GS_DS_E_4_5

...e, use a value that is lower than the specified value. Contacts 2 poles 4 poles Inductive load (cos φ = 0.4, L/R = 7 ms) Resistive load Contact configuration DPDT Contact structure Single Con...

https://www.omron-ap.co.nz/data_pdf/cat/MY-GS_DS_E_4_5_Datasheet (2020-06).pdf

PDFAxial Interface Unit CK3W-AX@@@@@ CSM_CK3W-AX_____...

...ower consumption AX2323P 4 points/channel (U, V, W, T) DirectPWM output Flags AX2323N 1-Vpp SIN/COS signal 1 point/channel (built into DirectPWM) Digital input 4 points/channel (HOME, PLIM, N...

https://www.omron-ap.co.nz/data_pdf/cat/ck3w-ax______ds_e_dita_3_5_csm1065373.pdf

PDFCP series CP1H CPU Unit CP1H-X@@D@-@/CP1H-Y@@D@-@

...rvice life of relays is as shown in the following diagram as a guideline. 50 30 20 10 5 125 VAC cos φ = 0.4 3 2 250 VAC cos φ = 0.4 0.2 0.3 0.5 0.7 3 0 47 55 Ambient temperature (˚C)...

https://www.omron-ap.co.nz/data_pdf/cat/cp1h_p080-e1_11_13_csm1004100.pdf

PDFCP series CP1L CPU Unit CP1L-EM@@D@-D/CP1L-EL@@D@-...

...osφ = 1), 24 VDC 4 A/common 5 VDC, 10 mA 150,000 operations (24 VDC) 100,000 operations (24 VAC cos = 0.4) 20,000,000 operations 15 ms max. 15 ms max. Output LED Circuit configuration Interna...

https://www.omron-ap.co.nz/data_pdf/cat/cp1l_p081-e1_10_12_csm1004101.pdf

PDFSmall Limit Switch D4V Compact Vertical Models Siz...

...ead 4 3 1 2 NO Cover Built-in Switch NO NC NC Connector Engineering Data Electrical Durability: cos φ = 1 Durability (× 104 operations) (Ambient temperature: 5°C to 35°C; ambient humidity: 40...

https://www.omron-ap.co.nz/data_pdf/cat/d4v_c139-e1-01.pdf

PDFModular Temperature Controller

...s functions Conforms to DeviceNet. Remote I/O communications Master-slave connections (polling, COS, or cyclic) Conforms to DeviceNet specifications. I/O allocation Input and output data can ...

https://www.omron-ap.co.nz/data_pdf/cat/ej1_ds_e_12_5_csm222.pdf

PDFSafety Light Curtain F3SJ Series

...s max. (not including sensor's response time) Number of contacts 3NO+1NC Rated load 25 VAC 5 A (cos ϕ = 1), 30 VDC 5 A L/R = 0 ms Rated current 5A Between sensors M12 connector (8-pin) Others...

https://www.omron-ap.co.nz/data_pdf/cat/f3sj_f074-e1_27_11_csm1816.pdf

PDFI/O Relay Terminal G70V I/O Relay Terminals with 1...

...N 61810-1 24V DC G70V-SOC16P(-1)-C4 G70V-ZID16P(-1) G70V-ZID16P(-1)-C16 single load: 250V AC 6A cos(phi)=1 16 loads: 250V AC 3A cos(phi)=1 16 loads: 30V DC 3A L/R=0ms 16 loads: 250V ...

https://www.omron-ap.co.nz/data_pdf/cat/g70v_j215-e1_2_19_csm1050154.pdf

PDFPower Relay G7J CSM_G7J_DS_E_6_6

...tage is one that is applicable to the Relay coil at 23°C. Contact Ratings Item Resistive load (cos φ = 1) Inductive load (cosφ = 0.4) Contact mechanism Double break Contact material Ag alloy...

https://www.omron-ap.co.nz/data_pdf/cat/g7j_ds_e_6_6_csm49.pdf

PDFDigital Timer H5CC New and improved design for eas...

...ON start I 0.01 to 99.99 s • Models with Contact Outputs 5 A at 250 VAC/30 VDC, resistive load (cos =1) Minimum applicable load: 10 mA at 5 VDC (failure level: P, reference value) Contact mat...

https://www.omron-ap.co.nz/data_pdf/cat/h5cc_l220-e1_3_1_csm1124436.pdf

PDFDigital Timer H5CX-@-N Ultra-compact Timer Provide...

...1, ton: Flicker ON Start 1 • Models with Contact Outputs 5 A at 250 VAC/30 VDC, resistive load (cos =1) Minimum applied load: 10 mA at 5 VDC (failure level: P, reference value) Contact materi...

https://www.omron-ap.co.nz/data_pdf/cat/h5cx-_-n_l111-e1_5_7_csm2122.pdf

PDFGeneral-purpose Limit Switch HL-5000 CSM_HL-5000_D...

...1 min between each terminal and non-current-carrying metal part 50/60 Hz Electrical Durability (cos dia. =1) (Operating temperature: +5°C to +35°C, Operating humidity: 40% to 70%RH) Operating...

https://www.omron-ap.co.nz/data_pdf/cat/hl-5000_ds_e_3_7_csm583.pdf

PDFUp/Down Counting Pulse Indicator

...mmunications communications Conforms to DeviceNet Master-Slave connection (polling, bit-strobe, COS, cyclic) Conforms to DeviceNet communications standards. I/O allocations Allocate any I/O d...

https://www.omron-ap.co.nz/data_pdf/cat/k3hb-c_ds_e_17_5_csm259.pdf

PDFTemperature Indicator K3HB-H CSM_K3HB-H_DS_E_14_6

...ported communi- Remote I/O communications cations Master-Slave connection (polling, bit-strobe, COS, cyclic) Conforms to DeviceNet communications standards. I/O allocations Allocate any I/O d...

https://www.omron-ap.co.nz/data_pdf/cat/k3hb-h_ds_e_14_6_csm260.pdf

PDFTimer Interval Indicator K3HB-P CSM_K3HB-P_DS_E_16...

...mmunications communications Conforms to DeviceNet Master-Slave connection (polling, bit-strobe, COS, cyclic) Conforms to DeviceNet communications standards. I/O allocations Allocate any I/O d...

https://www.omron-ap.co.nz/data_pdf/cat/k3hb-p_ds_e_16_5_csm261.pdf

PDFRotary Pulse Indicator K3HB-R CSM_K3HB-R_DS_E_16_5

...mmunications communications Conforms to DeviceNet Master-Slave connection (polling, bit-strobe, COS, cyclic) Conforms to DeviceNet communications standards. I/O allocations Allocate any I/O d...

https://www.omron-ap.co.nz/data_pdf/cat/k3hb-r_ds_e_16_5_csm262.pdf

PDFLinear Sensor Indicator K3HB-S CSM_K3HB-S_DS_E_11_...

...ported communi- Remote I/O communications cations Master-Slave connection (polling, bit-strobe, COS, cyclic) Conforms to DeviceNet communications standards. I/O allocations Allocate any I/O d...

https://www.omron-ap.co.nz/data_pdf/cat/k3hb-s_ds_e_11_6_csm263.pdf

結果 1121 - 11402042

国/地域選択

Related Contents