IAグローバル検索 |
...rvo + I/F unit PT Max.30 axes (nodes)/total length 50 m DI/O DI/O Counter Pulse output Stepping CW Limit/CCW Limit Note (1) The MECHATROLINK is registered trademark of YASKAWA ELECTRIC CORPOR...
https://www.omron-ap.com.ph/data_pdf/mnu/w419-e1-04_cs1w_mch.pdf
...leration Time Origin Search Deceleration Time Positioning Monitor Time 14 CCW Software Limit 15 CW Software Limit 16 Initial Pulse Designation 11 12 3-252 Description 1 (ON): FB started 0 (OF...
https://www.omron-ap.com.ph/data_pdf/mnu/w442-e1-01_fb_library.pdf
...tion : 100,000 pps Origin Search Settings 1 Default Use define origin operation Do not use. 1-1 CW Possible settings Do not use. When setting is read by CPU Unit When power is turned ON Use. ...
https://www.omron-ap.com.ph/data_pdf/mnu/w480-e1-09_cp1e.pdf
... decrements. Counter Input A A Incremental encoder Input B B Input Z Z (Reset i nput) Count up (CW) Count down (CCW) Phase A Phase B 1 2 3 2 1 0 Multiplication x1 1 2 3 4 5 6 5 4 9 10 11 12 1...
https://www.omron-ap.com.ph/data_pdf/mnu/w492-e1-04_cj1w-ct021.pdf
...he corresponding variable for the rotary axis attached to the end effector . --- You can select CW or CCW. LREAL The angle of arm 1 in its initial state. LREAL The angle of arm 2 in its initi...
https://www.omron-ap.com.ph/data_pdf/mnu/w539-e1-08_nj501-4500_4400_4320_4310_4300.pdf
...ion (Border point/ABS) Circular interpolation (Border point/INC) Circular interpolation (Center/CW/ABS) Circular interpolation (Center/CW/INC) Circular interpolation (Center/CCW/ABS)...
https://www.omron-ap.com.ph/data_pdf/mnu/w545-e1-05_sysmac-xr002.pdf
...dustrial Box PC Motion Control User's Manual (W559) 9 Motion Control Functions Y coordinate CCW CW CW : Clockwise rotation CCW : Counterclockwise rotation X coordinate With the MC Fu...
https://www.omron-ap.com.ph/data_pdf/mnu/w559-e1-07_ny532_ny512.pdf
.... • The motor rotation direction when viewing the shaft from the load side is called clockwise (CW) or counterclockwise (CCW). CW CCW For details, refer to the AC Servomotors/Servo D...
https://www.omron-ap.com.ph/data_pdf/mnu/w572-e1-04_sysmac-xr012.pdf
... acceleration, interpolation deceleration, and combined jerk for the two axes. Y coordinate CCW CW CW : Clockwise rotation CCW : Counterclockwise rotation X coordinate With the MC Fu...
https://www.omron-ap.com.ph/data_pdf/mnu/w579-e1-06_nx1p2.pdf
... Do not use. When setting is read by CPU Unit When power is turned ON Use. 1-1 Search Direction CW CW At start of operation CCW 1-2 Detection Method Method 0 Method 0 At start of ope...
https://www.omron-ap.com.ph/data_pdf/mnu/w614-e1-03_cp2e.pdf
... CONTROL MD ST S/L OVERWRITE COUNT CONTROL MD S CALCULATION WRITE --- --- --- CALCULATION WRITE CW A/S ID CODE READ ID ST H ID CODE READ ID H READ WITH ERROR CORRECTION QR ST A/H --- --- --- ...
https://www.omron-ap.com.ph/data_pdf/mnu/z272-e1-09_v680-chud_ch1d.pdf
...m Visible laser Laser medium Semiconductor laser - Maximum output 1 mW - Laser oscillation type CW (continuous wave) - Class 2 - 16 Fiber Laser Marker MX-Z2000H-V1 series Setup Manual (Z415) ...
https://www.omron-ap.com.ph/data_pdf/mnu/z415-e1-08_mx-z2000h-v1.pdf
...m Visible laser Laser medium Semiconductor laser - Maximum output 1 mW - Laser oscillation type CW (continuous wave) - Class 2 - Fiber Laser Marker MX-Z2000H-V1 series User’s Manual (Z416) 15...
https://www.omron-ap.com.ph/data_pdf/mnu/z416-e1-08_mx-z2000h-v1.pdf
...-NO Illumination color --- A22L-C@-24A-11M A22L-C@-24A-11A A22L-C@-24A-20M A22L-C@-24A-20A A22L-CW-T1-10M A22L-C@-T2-10M --A22L-C@-T2-01M A22L-C@-T1-11M A22L-C@-T2-11M A22L-C@-T1-20M A22L-CG-...
https://www.omron-ap.com/data_pdf/cat/a22_ds_e_8_12_csm607.pdf
... personal computer hard disk or floppy disk. Inputs Prepare the following inputs for each axis: CW and CCW limit input signals, origin proximity input signal, origin input signal, emergency s...
https://www.omron-ap.com/data_pdf/cat/cj1w-nc__3_ds_e_8_9_csm1849.pdf
... Module model.) 12 max. (6 per Pulse I/O Module) 4 max. (2 per Pulse I/O Module) Output method: CW/CCW or pulse + direction (The method is determined by the I/O wiring and the instructions us...
https://www.omron-ap.com/data_pdf/cat/cj2m-cpu3__-cpu1_-md21__ds_e_12_7_csm2201.pdf
... outputs) Line-driver inputs: Two axes for phases A, B, and Z Line-driver outputs: Two axes for CW and CCW CP1H Type Item Models CP1H-X CPU Units CP1H-XA@@@-@ CP1H-X@@@-@ CP1H-Y CPU Units CP1...
https://www.omron-ap.com/data_pdf/cat/cp1h_p080-e1_11_13_csm1004100.pdf
...r S-curve acceleration and deceleration (Duty ratio: 50% fixed) 2 outputs, 1 Hz to 100 kHz (CCW/CW or pulse plus direction) Duty ratio: 0.0% to 100.0% (specified in increments of 0.1% or 1%) ...
https://www.omron-ap.com/data_pdf/cat/cp1l_p081-e1_10_12_csm1004101.pdf
...lay window. Roller Lever Switch The head of the side rotary type can be converted in seconds to CW, CCW, or both-way operation. Follow the procedures on the right hand side for conversion (no...
https://www.omron-ap.com/data_pdf/cat/d4a-_n_ds_e_4_6_csm584.pdf
... the lever can be easily changed without using any tools. It can be set to clockwise operation (CW) or counterclockwise (CCW) operation. Use the procedure given at the right to change the ope...
https://www.omron-ap.com/data_pdf/cat/d4b-_n_ds_e_10_12_csm1251.pdf