IAグローバル検索 |
...he CPU Unit peripheral port: CS1W-CN (2 m, 6 m) When connecting to the CPU Unit’s RS-232C port: XW2Z- - (2 m, 5 m) (For details on model numbers, see 1-6-4 Connecting Cables) Using CX-Server ...
https://www.fa.omron.com.cn/data_pdf/mnu/w372-e1-16_cx-processtool.pdf
...eripheral ports: Model CS1W-CN (2 m, 6 m) When connecting to the CPU Unit’s RS-232C port: Model XW2Z- - (2 m, 5 m) (For details on model numbers, see 2-3 Connecting to CX-Process Tool and CX-...
https://www.fa.omron.com.cn/data_pdf/mnu/w374-03_cs1w-lc001.pdf
...nal block RS-485 Signal Pin No. GRD 1 SG 2 SDB 3 SDA 4 RDB 5 RDA 6 Terminal block Shield Shield XW2Z-070T-1 (0.7 m) XW2Z-200T-1 (2 m) Note: Set the DIP switch as follows for 2-wire R...
https://www.fa.omron.com.cn/data_pdf/mnu/w375-e1-05_cs1w-lc001.pdf
...焊接将它们焊到外部连接器。 2.间接连接信号线,把它们连接到端子板单元的螺丝端子。 通过标准产品Omron 扁平电缆(XW2Z-xxxB)将Omron端子板单元(XW2B-40G4或XW2B-40G5)连接到单元。 关于详情,参见2-3-2"连...
https://www.fa.omron.com.cn/data_pdf/mnu/w401-c1-01_cj1w-ct021.pdf
...it (XW2B-40G4 or XW2B- 40G5) is connected to the Unit via standard available Omron flat-cables (XW2Z-xxxB). Refer to 2-3-2 "Connector Wiring Methods" for more details. Specifications and Char...
https://www.fa.omron.com.cn/data_pdf/mnu/w401-e1-05_cj1w-ct021.pdf
...pheral ports: Model CS1W-CN@@@ (2 m, 6 m) When connecting to the CPU Unit's RS-232C port: Model XW2Z-@@@-@ (2 m, 5 m) (For details on model numbers, see 2-3 Connecting to CX-Process Tool.) Us...
https://www.fa.omron.com.cn/data_pdf/mnu/w406-e1-10_cs1w-lcb_cs1d-cpu_cs1g-cpu.pdf
...e computer is a half-pitch 14-pin connector, use a D-Sub 25-pin to Half-pitch Conversion Cable (XW2Z-S001). Specifications Remarks Communications protocol Tool bus --- Port No. 1 to 4 Default...
https://www.fa.omron.com.cn/data_pdf/mnu/w432-e1-01_cs1w-fln02_12.pdf
...PLC上的串行通信口的停止位数。 此设置只有在使用上位链接接口时要求设置。 •1或2位。 注意事项:当通过CS1W-CN226/626或XW2Z-200S-CV/500S-CV连接电缆连接装有CPU 机架上的CS1-DRM21(-V1)的CS系列PLC时,...
...Cable for PT Years L1 TEST L2/N ALARM OUTPUT DC30V,50mA L NORMAL:ON ALARM :OFF Expansion Cables XW2Z-200T/500T RS-232C Cable for Personal Computer CS1W-CN@@3 (30 cm, 70 cm, 2 m, 3 m, 5 m, 10 ...
https://www.omron-ap.co.in/data_pdf/cat/cj2h_cj2m_p059-e1_17_27_csm1004123.pdf
...minal Block Conversion Units and Cable Connector-Terminal Block Conversion Unit XW2@-20G@ Cable XW2Z-@@@J-B34 AC Servomotors Brake Cables (50 to 750 W or less) • Non-Flexible Cables R88A-CAKA...
https://www.omron-ap.co.in/data_pdf/cat/g5_series_i815-e1_29_32_csm2106.pdf
...(8ch)×2=16 compensating conductors for sensor input Advanced Temperature Control Units NX-HTC 1 XW2Z-***EE cable for sensor input 48.8 mm 85.4 mm 168.6 mm DIN Track Terminal Block XW5T(P2.5) ...
https://www.omron-ap.co.in/data_pdf/cat/nx-htc_nx-tc_ej1_e5dc-b_h237-e1_2_1_csm1124888.pdf
...n can be suppressed in acceleration/deceleration even in low-rigidity mechanical systems. Cable XW2Z-@@@J-B34 AC Servomotors ML-II Type AC Servo Drive Brake Cables (50 to 750 W or less) • Non...
https://www.omron-ap.co.in/data_pdf/cat/r88m-k_r88d-kt_r88d-kn_-ml2_-ect_i816-e1_9_16_csm2179.pdf
...ble. Control Panel Ultra-Compact Interface Wiring System XW2K Push-In terminal Connecting Cable XW2Z XW2Z-R For Connector-Terminal Block Conversion Units For I/O Relay Terminals I/O ...
https://www.omron-ap.co.in/data_pdf/cat/xs5_xs2_xw3_xs3_con_ds_e_3_4_csm2611.pdf
...s not required, which reduces replacement time. CJ-series Units CPU CJ1W-OD231 Conversion Cable XW2Z-S011 CJ1W-ID231 Conversion Cable XW2Z-S010 Connecting cable that was connected to...
https://www.omron-ap.co.in/data_pdf/mnu/p073-e1-03_c200h_cj2_replace.pdf
...s not required, which reduces replacement time. CJ-series Units CPU CJ1W-OD231 Conversion Cable XW2Z-S011 CJ1W-ID231 Conversion Cable XW2Z-S010 Connecting cable that was connected to...
https://www.omron-ap.co.in/data_pdf/mnu/p074-e1-04_c200hs_cj2_replace.pdf
...s not required, which reduces replacement time. CJ-series Units CPU CJ1W-OD231 Conversion Cable XW2Z-S011 CJ1W-ID231 Conversion Cable XW2Z-S010 Connecting cable that was connected to...
https://www.omron-ap.co.in/data_pdf/mnu/p075-e1-04_c200hx_hg_he_cj2_replace.pdf
...(6.0 m) CS1W-CN118 (See note 1.) CS1W-CN226 CS1W-CN626 9-pin 10-pin RS-232C port (9-pin female) XW2Z-200S-CV/200S-V (2.0 m) XW2Z-500S-CV/500S-V (5.0 m) XW2Z-200S-CV/-200S-V ...
https://www.omron-ap.co.in/data_pdf/mnu/w448-e1-07_cx-motion-mch.pdf
... RS-232C Port Cables: Connection to Peripheral port: CS1W-CN226/626 Connection to RS-232C port: XW2Z-200S-CV/500S-CV Refer to Appendix3-2 Connections via Ethernet to directly connect the CX-P...
https://www.omron-ap.co.in/data_pdf/mnu/w468-e1-01_plc-based_process.pdf
...le (A connector - B connector), 5.0 m max. Programming Device Connecting Cables for serial port XW2Z-200S-CV Connects to IBM PC/AT computer Uses static-resistant connector. XW2Z-500S...
https://www.omron-ap.co.in/data_pdf/mnu/w472-e1-16_cj2h-cpu6_eip_cj2m-cpu.pdf
...Cable for PT Years L1 TEST L2/N ALARM OUTPUT DC30V,50mA L NORMAL:ON ALARM :OFF Expansion Cables XW2Z-200T/500T RS-232C Cable for Personal Computer CS1W-CN@@3 (30 cm, 70 cm, 2 m, 3 m, 5 m, 10 ...
https://www.omron-ap.co.nz/data_pdf/cat/cj2h_cj2m_p059-e1_17_27_csm1004123.pdf