IAグローバル検索 |
...tes (1,600 points) OUT : 200 bytes (1,600 points) I/O connections Up to two Poll, Bitstrobe, or COS/Cyclic connections can be used. Explicit messages Up to 552 bytes Max. No. of connected sla...
https://www.omron.com.tw/data_pdf/cat/drt2_devicenet_q102-e1_20_35_csm2147.pdf
...eviceNet. Communications functions Remote I/O communications Master-slave connections (polling, COS, or cyclic) Conforms to DeviceNet specifications. I/O allocation Input and output data can ...
https://www.omron.com.tw/data_pdf/cat/ej1_ds_e_12_5_csm222.pdf
...標準UL61010-1、CSA C22.2 No.1010-1 EMC指令請參閱第7頁。 通訊協定遵循DeviceNet標準通訊功能遠端I/O通訊功能 Master/Slave連接(poll/COS/Cyclic) 遵循DeviceNet通訊規範標準 I/O分配設定透過配置器分...
https://www.omron.com.tw/data_pdf/cat/ej1_sgtd-045_tw_5_8.pdf
...0 3 5 10 20 30 100 300 500 ௦ᘉႬࢻȠ Aȡ ௦ᘉႬᔇȞVȟ DCႬད॓ၸ ȞL/Rɶ7msȟ DCႬߣ॓ၸ ACႬߣ॓ၸ AC Ⴌད॓ၸ cosɶ0.4 400 100 50 30 10 01234567 ձԪȠ × 104 Ԫȡ ௦ᘉႬࢻȞAȟ G6B-4@Ȟዀྦȟ -47@Ȟାटεܓȟ ȁAC 250VႬད॓ၸȞcosɶ0.4ȟ ȁD...
https://www.omron.com.tw/data_pdf/cat/g6b-4__nd_ds_tw_8_8.pdf
...100 50 30 10 5 3 1 011.52345678910 ձԪȠ × 104Ԫȡ ௦ᘉႬࢻȞAȟ AC 250VႬߣ॓ၸ DC 30VႬߣ॓ၸ AC 250VႬད॓ၸcosɶ0.4 DC 30VႬད॓ၸL/Rɶ7ms 72±0.2 2-4ЍܗȞ2-M3.5ȟ 41±0.3 2134 ഷτ84 72±0.3 6 41±0.3 ഷτ48 21.5 ഷτ31 17-...
...V) 最大容許電壓(V) 消耗電力 (mW) DC 12 18.7 720 70%以下 * 10%以上130%約200 24 10.5 2,880 項目負載電阻負載(cos=1) 額定負載AC250V 3A、DC30V 3A 額定通電電流5A 最大接點電壓AC250V、DC30V ...
https://www.omron.com.tw/data_pdf/cat/g6d-f4b_g3dz-f4b_ds_tw_5_4.pdf
...V) 最大容許電壓(V) 消耗電力 (mW) DC 12 18.7 720 70%以下 * 10%以上130%約200 24 10.5 2,880 項目負載電阻負載(cos=1) 額定負載AC250V 3A、DC30V 3A 額定通電電流5A 最大接點電壓AC250V、DC30V ...
https://www.omron.com.tw/data_pdf/cat/g6d-f4b_g3dz-f4b_ds_tw_6_3.pdf
...61810-1 24V DC 24V DC 0.05A L/R=0ms G70V-SID16P(-1)-C16 G70V-SOC16P(-1) single load: 250V AC 6A cos(phi)=1 16 loads: 250V AC 3A cos(phi)=1 16 loads: 30V DC 3A L/R=0ms 16 loads: 250V ...
https://www.omron.com.tw/data_pdf/cat/g70v_j215-e1_2_18_csm1050154.pdf
...61810-1 24V DC 24V DC 0.05A L/R=0ms G70V-SID16P(-1)-C16 G70V-SOC16P(-1) single load: 250V AC 6A cos(phi)=1 16 loads: 250V AC 3A cos(phi)=1 16 loads: 30V DC 3A L/R=0ms 16 loads: 250V ...
https://www.omron.com.tw/data_pdf/cat/g70v_sdbc-001_tw_2_12.pdf
...30 50 1 3 5 10 30 50 100 300 500 1,000 電壓(V) 電流 A DC電感負載 DC電阻負載 AC電阻負載 AC電感負載 cos0.4 LR7ms 開關電流(A) 1 357 10 30 50 70 100 300 500 700 1,000 3,000 5,000 0 1 2 3 4 5...
...開閉回数︵ × 104 回︶ 1,000 700 500 300 100 70 50 30 10 5 01234 接点電流(A) 7 DC24V L/R=7ms DC24V cos=1 AC250V cos=1 AC250V cos=0.4 H3CA 3 連接 ■內部連接 ●H3CA-A型...
...1 to 99.99 s Control output •Models with Contact Outputs 5 A at 250 VAC/30 VDC, resistive load (cos =1) Minimum applicable load: 10 mA at 5 VDC (failure level: P, reference value) Contact mat...
https://www.omron.com.tw/data_pdf/cat/h5cc_l220-e1_3_1_csm1124436.pdf
...1 to 99.99 s Control output •Models with Contact Outputs 5 A at 250 VAC/30 VDC, resistive load (cos =1) Minimum applied load: 10 mA at 5 VDC (failure level: P, reference value) Contact materi...
https://www.omron.com.tw/data_pdf/cat/h5cx-_-n_l111-e1_5_7_csm2122.pdf
...考值) DC125V cosφ=1且最大0.15A時可開閉(使用壽命10萬次) L/R=7ms且最大0.1A時可開閉(使用壽命10萬次) DC30V L/Rɶ7ms AC250V/DC30V cosɶ1 AC250V cosɶ0.4 0 1 2 3 4 5 1,000 500 100 50...
https://www.omron.com.tw/data_pdf/cat/h5cx-_-n_sgta-028_tw_5_5.pdf
...rt 1 One-shot output time 0.01 to 99.99 s Control output 5 A at 250 VAC/30 VDC, resistive load (cos =1) Minimum applied load: 10 mA at 5 VDC (failure level: P, reference value) Contact materi...
https://www.omron.com.tw/data_pdf/cat/h5cz_l116-e1_6_3_csm2142.pdf
...考值) DC125V cosφ=1且最大0.15A時可開閉(使用壽命10萬次) L/R=7ms且最大0.1A時可開閉(使用壽命10萬次) DC30V L/Rɶ7ms AC250V/DC30V cosɶ1 AC250V cosɶ0.4 0 1 2 3 4 5 1,000 500 100 50...
https://www.omron.com.tw/data_pdf/cat/h5cz_sgta-032_tw_6_4.pdf
...or the operating conditions and environment beforehand. Engineering Data Electrical Durability (cos dia. =1) (Operating temperature: +5°C to +35°C, Operating humidity: 40% to 70%RH) Structure...
https://www.omron.com.tw/data_pdf/cat/hl-5000_ds_e_3_6_csm583.pdf
...upported communications Remote I/O communications Master-Slave connection (polling, bit-strobe, COS, cyclic) Conforms to DeviceNet communications standards. I/O allocations Allocate any I/O d...
https://www.omron.com.tw/data_pdf/cat/k3hb-c_ds_e_17_5_csm259.pdf
...參閱「K3HB 型數位面板儀錶通訊篇使用者手冊」。 通訊協定DeviceNet標準通訊功能遠端I/O 通訊功能・主站/從站連接 (Poll/Bit-Strobe/COS/Cyclic) ・依據DeviceNet通訊規範標準 IO分配設定・透過配置器分...
...ported communi- cations Remote I/O communications Master-Slave connection (polling, bit-strobe, COS, cyclic) Conforms to DeviceNet communications standards. I/O allocations Allocate any I/O d...
https://www.omron.com.tw/data_pdf/cat/k3hb-h_ds_e_14_6_csm260.pdf