Primary Contents

IAグローバル検索結果

国/地域選択

IAグローバル検索
結果 1561 - 15801856
PDF[I502-E1-05] R88M-U[], R88D-UP[] AC Servo Motors/D...

...aft of the motor as follows: counterclockwise rotation (CCW) is forward and clockwise rotation (CW) is reverse. General Instructions 1. Refer to Precautions first and carefully read and be su...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/i502-05_r88m-u_r88d-up_.pdf

PDF[I512-E1-02] R88M-U[], R88D-UT[] AC Servo Motors/D...

...ilter d degree F 0 0 0 1 ––– Explanation CCW direction is taken upon “+” command. (See note 5.) CW direction is taken upon “+” command. Origin errors are detected. Origin errors are not detec...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/i512-02_r88m-u_r88d-ut_.pdf

PDF[I522-E1-03] R88M-UE[], R88D-UEP[] AC Servomotors/...

...command pulse mode Feed pulse (PULS)/Direction signal (SIGN) Forward pulse (CCW)/Reverse pulse (CW) (Factory setting) 90_ differential phase (A/B phase) signal (1×) 90_ differential phase (A/...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/i522-e1-03_r88m-ue__r88d-uep_.pdf

PDF[I524-E1-04] FND-X[]/X[]-SRT Position Drivers User...

... Alarm reset 19 OGND Deceleration stop Origin proximity RUN command 5 6 CCW limit input 20 STOP CW limit input 3 4 CCWL D Connectors Used Sumitomo 3M Receptacle at Position Driver Soldered pl...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/i524-04_fnd-x__x_-srt.pdf

PDF[I531-E1-09] R88M-W[], R88D-WT[] AC Servomotors/Se...

...GND Torque command input ground 3 PCOM Open p collector comd power supply l mand 13 18 7 +PULS/ CW/A 8 –PULS/ CW/A 11 +SIGN/ CCW/B 12 –SIGN/ CCW/B 14 –ECRST 15 +ECRST 4 SEN 2 SENGND ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/i531-e1-09_r88m-w_r88d-w.pdf

PDF[I532-E1-01] 3G3RV High-Function General-Purpose I...

...CW) when motor rotation is forward. Generally, PG is A-phase driven when rotation is clockwise (CW) see from the input axis. Also, motor rotation is counter-clockwise (CCW) seen from the outp...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/i532-01_3g3rv.pdf

PDF[I533-E1-04] R7M-A[], R7D-AP[] Servomotors/Servo D...

...mand Pulse Input Setting SMARTSTEP A-series command pulse input setting can be switched between CW/CCW (2-pulse) and SIGN/PULS (single-pulse) methods to easily adapt to Position Controller ou...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/i533-e1-04_r7m-a_r7d-ap.pdf

PDF[I534-E1-02] R7M-A[], R7D-AP[] Servomotors/Servo D...

...on for parameters with individually set digits 0 CCW direction is taken for positive command. 1 CW direction is taken for positive command. 1 Control mode selection 1 Position control by puls...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/i534-e1-02_r7m-a_r7d-ap.pdf

PDF[I544-E1-06] R88M-W[], R88D-WN[]-ML2 AC Servomotor...

...tches 1 1 3 Default setting Unit Setting range Restart power? 0000 --- --- Yes 0002 --- --- Yes CW direction is taken for positive command Not used. 2 4-8 Setting 1 3 Pn001 Name Stop selec0 t...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/i544-e1-06_r88m_w_r88d_wn_ml2.pdf

PDF[I553-E1-01] R7M-Z[], R7D-ZP[] Servomotors/Servo D...

...Symbol No. No. No. Wire/mark colors Symbol +24VIN 1 1 5 Blue/Red(-) +24VIN 2 2 3 3 4 4 5 5 6 6 +CW/PULS 7 7 1 Pink/Red(-) +CW/PULS -CW/PULS 8 8 2 Pink/Black(-) -...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/i553-e1-01_r7m-z_r7d-zp.pdf

PDF[I554-E1-01] R7D-ZN[]-ML2 Servomotors/Servo Driver...

... the end of the motor’s output shaft, counterclockwise (CCW) rotation is forward and clockwise (CW) rotation is reverse. Reverse Forward 3-16 Chapter 3 Specifications 3-2-2 Characteristics It...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/i554-e1-01_r7m-z_r7d-zn.pdf

PDF[I562-E1-09] R88M-G[], R88D-GT[] Servomotors/Servo...

...tions between multiple Servo Drives and a computer. Forward and Reverse Motor Rotation Reverse (CW) Forward (CCW) When the motor output shaft is viewed from the end, counterclockwise (CCW) ro...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/i562-e1-09_r88m-g__r88d-gt_.pdf

PDF[I566-E1-07] R88M-G[], R88D-GN[]-ML2 AC Servomotor...

...er to Servo Drive Display and Settings on page 6-3. Forward and Reverse Motor Rotation Reverse (CW) Forward (CCW) When the motor output shaft is viewed from the end, counterclockwise (CCW) ro...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/i566-e1-07_r88m-g_r88d-gn_-ml2.pdf

PDF[I877-E1-01] G Series with General-purpose Pulse T...

...n install wiring and set parameters. Host controller Host controller Maximum input frequency of CW (reverse) CCW (forward) pulse output specifications drive pulse input pulse input circuit 24...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/i877-e1-01_gseries_to_g5series_replace.pdf

PDF[9308674-5A] MX-Z2000H/Z2050H/Z2055H ファイバレーザマーカ 取扱...

...や散乱光の目又は皮膚への被ばくを避けること 半導体レーザ Yb:Fiber レーザ最大出力:1mW 最大出力:40W パルス幅:CW 最大ピークパワー:30kW 波長:655nm パルス幅:1-500ns 波長:1062nm クラス4レー...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/mx-z2000h_mx-z2050h_mx-z2055h_inst-9308674-5a.pdf

PDF[9309887-5A] MX-Z2000H/Z2050H/Z2055H Fiber Laser M...

...m Visible laser Laser medium Semiconductor laser - Maximum output 1 mW - Laser oscillation type CW (continuous wave) Class 危険―可視及び不可視レーザ放射 DANGER—VISIBLE AND INVISIBLE LASER RAD...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/mx-z2000h_mx-z2050h_mx-z2055h_inst-9309887-5a.pdf

PDF[O008-E1-04] 3F88L-160/162 Cam Positioner User's M...

... and Origin Shift.) H Backlash Compensation • Sets a difference between the detection angles in CW and CCW directions to absorb mechanical vibration. (Refer to 3-6-5 Backlash Compensation..) ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/o008-e1-04_3f88l-160_162.pdf

PDFo010-e1-01_fqm1-cm001_mmp21_mma21.pdf

...uts, for Servomotors/Servo Drivers • For stepping motors, combination with basic I/O and pulse (CW) + direction control is possible. 7-6-12 PLS2(887) Pulse Output Direction Priority Mode Trap...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/o010-e1-01_fqm1-cm001_mmp21_mma21.pdf

PDFo011-e1-01_fqm1-cm001_mmp21_mma21.pdf

...pulse output has started. ON: Pulse being output Bit 08 Indicates the direction of virtual OFF: CW pulse currently being output. ON: CCW Bit 07 Indicates whether or not the vir- OFF: Pulse be...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/o011-e1-01_fqm1-cm001_mmp21_mma21.pdf

PDFo012-e1-03_fqm1-com_mm.pdf

...86) is used in electronic cam mode (ring), the pulse output can be set to pass through 0 in the CW direction or CCW direction. When PULS(886) is used in electronic cam mode (linear or ring), ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/o012-e1-03_fqm1-com_mm.pdf

結果 1561 - 15801856

国/地域選択

Related Contents