Primary Contents

IAグローバル検索結果

国/地域選択

IAグローバル検索
結果 141 - 156156
PDFCat. No. W166-E1-03 SYSMAC C200H-NC211

...33 X Axis 9 11 Y Axis 31 33 Specification Input current is 6 mA (at 12 V)) to (at 24 V); o 13 3 mA (a ); f other specifications remain the same Signal is a line-driver ssignal g a correspondi...

https://www.omron.com.vn/data_pdf/mnu/w166-e1-03_c200h_nc211.pdf

PDF[W166-E1-03] C200H-NC211 Position Control Unit Ope...

...33 X Axis 9 11 Y Axis 31 33 Specification Input current is 6 mA (at 12 V)) to (at 24 V); o 13 3 mA (a ); f other specifications remain the same Signal is a line-driver ssignal g a correspondi...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w166-e1-03_c200h_nc211.pdf

PDF[W455-E1-08] GRT1 Series Slice I/O Units Operation...

...ex (–300 to 6,300). If the input current is below the input range (input current less than 3.04 mA), a disconnection is detected and the data is set to 7FFF hex. Conversion data Hexadecimal (...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w455-e1-08_grt1.pdf

PDF[W457-E1-08] CRT1 Series CompoNet Slave Units and ...

...ue falls below the input range such as for a disconnected line (input current is less than 3.04 mA), a disconnected line detection function activates and data is set to 7FFF Hex. Conversion d...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w457-e1-08_crt_crs1-rpt01.pdf

PDFUSER’S MANUAL SYSDRIVE RV Series

... output axis). Application Precautions If the analog signal input level is 0 to 10 V or 4 to 20 mA, a forward torque reference will not be applied. To apply reverse torque, use an input level...

https://www.fa.omron.com.cn/data_pdf/closed/mnu/i549-e1-01_3g3rv-v1.pdf

PDFOPERATION MANUAL Cat. No. W238-E1-10

...a should be input. X1 = 400, X2 = 1500, Y1 = 1000, Y2 = 3000 If the input from the sensor is 10 mA, a value corresponding to the input will be 2091 (i.e., 20.91 centimeters) in this case. X1 ...

https://www.fa.omron.com.cn/data_pdf/closed/mnu/w238-e1-10_cqm1-b7a_g7_lk_ad_da_sen_lse_tc.pdf

PDFOPERATION MANUAL Cat. No. W371-E1-03

... below 0.8 V or 3.2 mA, respectively, when the input range is set to either 1 to 5 V or 4 to 20 mA, a disconnection of the input line is detected and the line disconnection detection function...

https://www.fa.omron.com.cn/data_pdf/closed/mnu/w371-e1-03_cpm2b.pdf

PDF[I516-E1-05] 3G3FV High-function General-purpose I...

... V (A 10-V input limits the torque to 100% of the motor’s rated torque.) • Terminal 14: 4 to 20 mA (A 20-mA input limits the torque to 100% of the motor’s rated torque.) 6-4 Chapter 6 Advance...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/i516-e1-05_3g3fv.pdf

PDF[N090-E1-01B] K3NX Process Meter Operation Manual

...imately 5 V is imposed between COM and terminals 5 to 7 with a current flow of approximately 18 mA (a nominal value) at the time of external input shortcircuiting. 13 Output Board 2-3 Output ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/n090-e1-01b_k3nx.pdf

PDF[N093-E1-01A] K3NR Frequency/Rate Meter Operation ...

...imately 5 V is imposed between COM and terminals 5 to 7 with a current flow of approximately 18 mA (a nominal value) at the time of external input shortcircuiting. 15 Output Board 2-3 Output ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/n093-e1-01a_k3nr.pdf

PDF[W371-E1-03] SYSMAC CPM2B Programmable Controller ...

... below 0.8 V or 3.2 mA, respectively, when the input range is set to either 1 to 5 V or 4 to 20 mA, a disconnection of the input line is detected and the line disconnection detection function...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w371-e1-03_cpm2b.pdf

PDFCat. No. N090-E1-1B Process Meter

...imately 5 V is imposed between COM and terminals 5 to 7 with a current flow of approximately 18 mA (a nominal value) at the time of external input short- circuiting. Base Unit Section 2-2 14 ...

https://www.fa.omron.com.cn/data_pdf/closed/mnu/n090-e1-01b_k3nx.pdf

PDFCat. No. N093-E1-1A Frequency/Rate Meter

...imately 5 V is imposed between COM and terminals 5 to 7 with a current flow of approximately 18 mA (a nominal value) at the time of external input short- circuiting. Input Block Section 2-2 1...

https://www.fa.omron.com.cn/data_pdf/closed/mnu/n093-e1-01a_k3nr.pdf

PDFOPERATION MANUAL Cat. No. W457-E1-08

...ue falls below the input range such as for a disconnected line (input current is less than 3.04 mA), a disconnected line detection function activates and data is set to 7FFF Hex. 189C (6300) ...

https://www.fa.omron.com.cn/data_pdf/closed/mnu/w457-e1-08_crt_crs1-rpt01.pdf

PDFOPERATION MANUAL Cat. No. W455-E1-08

...ex (–300 to 6,300). If the input current is below the input range (input current less than 3.04 mA), a discon- nection is detected and the data is set to 7FFF hex. 0CE4 (3300) 0BB8 (3000) F44...

https://www.omron.com.tw/data_pdf/closed/mnu/w455-e1-08_grt1.pdf

検索結果 : オムロン制御機器

...索 商品検索:全1件が検索されました。(1-1件を表示) 商品名/形式/概要 ダウンロード マイカタログ 電磁継電器 MA□A 1995年03月受注終了 ※受注終了品のカタログ、マニュアルのダウンロードにはI-Webメン...

https://www.fa.omron.co.jp/search/product/index?keyword=MA□A

結果 141 - 156156

国/地域選択

Related Contents