IAグローバル検索 |
... Modular Temperature Controller E5ZN E5ZN-SCT24S Terminal Unit Digital Controller E5AC E5AC-@@@@SM-@@@ E5EC E5EC-@@@@SM-@@@ Temperature Controller (Digital Controller) E5AN/E5EN/E5CN...
https://www.fa.omron.com.cn/data_pdf/closed/cat/ns_v405-e1_12_12_csm2140.pdf
...安全门开关 D4NL P16 电磁锁定安全门开关 D4JL P16 灵活·安全单元 G9SX 整体停止、部分停止 P22 停止检测单元 G9SX-SM 停止检测 P22 低速检测单元 G9SX-LM 低速检测 P22 索取样本、查阅产品详情请点击 www....
https://www.fa.omron.com.cn/data_pdf/closed/cat/safety_component_selectionguide_sgfm-cn5-051_1_1.pdf
...Data2 SUB A田urnent2iSSubtract曾dfromargumentltoobtainth{蓼OP㊧rationresu|t OataT Daぬ2 MUし Argumentパsm碗ip肖edbyargum⑤nt2toobtain蜘eoperationresωt. Da抽1 Data2 Dl∨ Argument†isdlv}d聞byargu...
https://www.fa.omron.com.cn/data_pdf/closed/mnu/h070-e1-02_es100x.pdf
...ires Solderless terminal or wire without soldering Note Applying a torque of greater than 0.5 N Sm may damage the terminal block. If the tightening torque is insufficient, however, wires may ...
https://www.fa.omron.com.cn/data_pdf/closed/mnu/i527-e1-06_3g3mv.pdf
...Resistor Unit, a shutoff sequence for the power supply must be made using a thermal relay trip. SM SC SP A1 A2 M5 M6 MA M8 MC +V AC -V MP AC RP R+ R- S1 E(G) E(G) S2 S3 S4 S5 M3 M4 M1 M2 S6 S...
https://www.fa.omron.com.cn/data_pdf/closed/mnu/i532-01_3g3rv.pdf
...ager Communication Objects 1C00 hex Sync Manager communication type Sub-index 0: Number of used SM channels Setting range:Unit:Default setting: 04 hex Size: 1 byte (U8) Access: RO PDO map: ...
https://www.fa.omron.com.cn/data_pdf/closed/mnu/i574-e1-06_3g3ax-mx2-ect_rx-ect.pdf
...( oo oo oo `,,,III,■、■■、● ' 碍竃千失 RR LR 皿 CR GR 拙 旺 JR 服W 肌 HW ℃W GW D" 侃隅 汀W #11 $R %R #W $W %W SM CS 狸E Gl RK KF CK MM 鴨 PR PW QQ ZX 芸醤 犯 XE 椋 6-3通信歩藤依皐.ヒ位計算机...
https://www.fa.omron.com.cn/data_pdf/closed/mnu/oez-zdp00101a_cqm1h_discon.pdf
...erCAT slave. Transmit PDO TxPDO A Process Data Object sent from an EtherCAT slave. Sync Manager SM Collection of control elements to coordinate access to concurrently used objects. Distribute...
https://www.fa.omron.com.cn/data_pdf/closed/mnu/q179-e1-01_fzm1.pdf
... that reason, there is no response. The following 4 commands can be given. command Title Action SM PT memory ($W) change notice Notify host of PT memory $W changes. SB PT memory ($B) change n...
https://www.fa.omron.com.cn/data_pdf/closed/mnu/v085-e1-07_ns15_12_10_8_5.pdf
...2), 4), 9) Y Output YES YES YES YES 1), 2), 4), 9) M Auxiliary Relay YES YES YES YES 1), 2), 4) SM Special Relay YES YES YES YES 1), 2), 4) L Latch relay YES YES YES YES 1), 2), 4) S Step rel...
https://www.fa.omron.com.cn/data_pdf/closed/mnu/v092-e1-13_ns_nsj_nsh.pdf
...00 to F 032767 Edge relays V 000000 to V 032767 Link relays B 000000 to B 007FFF Special relays SM 000000 to SM 002047 Link special relays SB 000000 to SB 0007FF Step relays S 000000...
https://www.fa.omron.com.cn/data_pdf/closed/mnu/v105-e1-03_nv3w_nv4w_nv3q.pdf
... 2-4-1 SIEMENS S7-200 Device Bit Address Word Address Format SCR节点S.B 0.0-31.7 ------ DD.O 特殊内存位SM.B 0.0-549.7 ------ DDD.O 计数器位Cnt 0-255 ------ DDD.O 计数器位Tim 0-255 ------ DDD....
https://www.fa.omron.com.cn/data_pdf/closed/mnu/v108-cn5-21_discon.pdf
...ice Bit Address Word Address Format Notes SCR Nodes S.B 0.0~31.7 ------ DD.O Special Memory Bit SM.B 0.0~549.7 ------ DDD.O Counter Bit Cnt 0~255 ------ DDD.O Counter Bit Tim 0~255 ------ DDD...
https://www.fa.omron.com.cn/data_pdf/closed/mnu/v108-e1-22_nb3q_nb5q_nb7w_nb10w.pdf
...= OFF) Pre-batch display Main batch display SP numerical value display Batch accumulated value (SM) display Batch accumulated value display Switch to Re- mote Button SP (1 Batch) Change Butto...
https://www.fa.omron.com.cn/data_pdf/closed/mnu/w372-e1-16_cx-processtool.pdf
...= OFF) Pre-batch display Main batch display SP numerical value display Batch accumulated value (SM) display Click this button to move to the Tuning screen. See 3-7 Tuning Screen for details. ...
https://www.fa.omron.com.cn/data_pdf/closed/mnu/w373-e1-04_ws02-lctc1-j.pdf
...= OFF) Pre-batch display Main batch display SP numerical value display Batch accumulated value (SM) display Batch accumulated value display Switch to Remote Button SP (1 Batch) Change Button ...
https://www.fa.omron.com.cn/data_pdf/closed/mnu/w428-e1-03_ws02-lcmc1-ev2.pdf
...put speed) d(memoryall clear) E(INHIBITinpu.t filter) 1(eyoperation 〔コ囚・r 回団・r囚回囚・r図 Indication SM V醐 Ss滉固固目V圏 S固目s国 s週 SM圃 Remarks Theangledisplayshpws either...
https://www.fa.omron.com.cn/data_pdf/closed/mnu/z033-e1-04_h8pr-8(p)_16(p)_24(p).pdf
...X2–X1)/2’Search pos in the center of model 10510 SY=(Y2–Y1)/2 10520 SMPUT 0,0,X1,Y1,X2,Y2,SX,SY’SM 0 registration 10530 SMMODE 0,0,0,70,0’Search model 0 10540’Density correlation, min. and ma...
https://www.fa.omron.com.cn/data_pdf/closed/mnu/z109-02a_f350.pdf
...acter code for 1st candidate 2nd candidate C2 Character code for 2nd candidate Similarity level SM Similarity level of 1st candidate Diff. level DS Similarity level of 1st candidate - similar...
https://www.fa.omron.com.cn/data_pdf/closed/mnu/z147-e1-02_f160.pdf
...immediately. Multi Trigger (approximately 4 Tags) Sleep SS Multi Trigger (approximately 8 Tags) SM Multi Trigger (approximately 16 Tags) SL Single Auto Sleep R6 SU Single Auto Standby WU Anot...
https://www.fa.omron.com.cn/data_pdf/closed/mnu/z149-e1-02_v690-hmg01a_d8kr01a_l01.pdf