PDFw376-e1-08_cs1w_nc.pdf

...Setting number of unused axes Not supported Not supported Supported Supported Supported Setting CW/CCW pulse output direction Not supported Not supported Not supported Supported Supported Set...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w376-e1-08_cs1w_nc.pdf

PDFw378-e1-02_cs1w-hio_hcp_hca_v1.pdf

...atible with absolute encoders (Supported only by lot numbers of 0209__ or higher) • ABS linear (CW-) counter • ABS linear (CW+) counter • ABS ring mode counter (Set in Unit Setup Are...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w378-e1-02_cs1w-hio_hcp_hca_v1.pdf

PDFw384-e1-01_cs1w-hio01_hcp22_hca22.pdf

... to complete the specified output. Description PLS2(––) is used to output a specified number of CW or CCW pulses from port 1 or 2 in a trapezoid. The pulse output starts at the specified star...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w384-e1-01_cs1w-hio01_hcp22_hca22.pdf

PDF[W395-E1-09] CJ1M-CPU21/CPU22/CPU23 CPU Units Oper...

... outputs to perform positioning or speed control with a servo driver that accepts pulse inputs. CW/CCW Pulse Outputs or Pulse + Direction Outputs The pulse output mode can be set to match the...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w395-e1-09_cj.pdf

PDF[W419-E1-04] CS1W-MCH71 Motion Control Unit Operat...

...rvo + I/F unit PT Max.30 axes (nodes)/total length 50 m DI/O DI/O Counter Pulse output Stepping CW Limit/CCW Limit Note (1) The MECHATROLINK is registered trademark of YASKAWA ELECTRIC CORPOR...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w419-e1-04_cs1w-mch71.pdf

PDFw433-e1-10_cx-position.pdf

...tion Control Units CJ-series Position Control Units Functions Switching pulse output direction (CW or CCW) Reversal mode 3 in origin search operation Position-preset origin search Support Sof...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w433-e1-10_cx-position.pdf

PDFw559-e1-07_ny532_ny512.pdf

...dustrial Box PC Motion Control User's Manual (W559) 9 Motion Control Functions Y coordinate CCW CW CW : Clockwise rotation CCW : Counterclockwise rotation X coordinate With the MC Fu...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/w559-e1-07_ny532_ny512.pdf

PDF[Z033-E1-04] H8PR-8(P)/16(P)/24(P) Rotary Position...

...r switch ⑬鷲籔 switches RUNρROG ■ ⊂=MuLTt 勘_百日 TEACHCOM ご = 《 苗印白}1 li 」1 ⑱Enterkey⑰Upkey⑯Downkey CW、cwl 口占 1 ⑮MULTIkey 巨霊! keys 3■21ndicators Name ①② ③ ④ ⑤ ⑥ ⑦ ⑧ ⑨ Controloutpu...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z033-e1-04_h8pr-8(p)_16(p)_24(p).pdf

PDF[Z148-E1-06] V670-CD1D-V1/H11/H51(Q)/D13F03/D13F01...

.......................................................................... 5-11 Computation Write (CW) ..............................................................................................

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z148-e1-06_v670-cd1d-v1_h11_h51(q)_d13f0_(h).pdf

PDF[Z150-E1-01] V530-C300E 2-Dimensional Code Reader ...

...via RS-232C @YW page 135 Read Scene Data via RS-232C @CR page 137 Write Scene Data via RS-232C @CW page 143 Read Communications Settings via RS-232C @RR page 144 Write Communications Settings...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z150-e1-01_v530-c300e.pdf

PDFz199-e1-02_h8ps.pdf

...d operation. Refer to "3.11 All Protection Function". CHECK CAM STEP CAM STEP PRGM TEST RUN ADV CW 1234 ON OFF ● Cam protection function 8 output 16 output 32 output ● Step-number limit funct...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z199-e1-02_h8ps.pdf

PDF[Z204-E1-02] V670-CF01/D13F01(H)/D13F03 Electromag...

...rror, or that an overflow/underflow occurred in the calculation of a Computation Write command (CW). 2 Abort status Indicates a communication with a Tag was aborted after it was started, usin...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z204-e1-02_v670-cf01_d13f0_.pdf

PDFz219-e1-05_v600-chud_ch1d-v2_ch1d-psi.pdf

...when the Data Carrier enters the communications area after the activate switch is pressed. p.87 CW CALCULATION WRITE Writes the calculation results for the memory data to the Data Carrier. FL...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z219-e1-05_v600-chud_ch1d-v2_ch1d-psi.pdf

PDF[Z314-E1-05] FQ-MS12[] Specialized Vision Sensor f...

...he [Reverseturn trigger detection]. Set the [Backlash width]. Description Direction of rotation CW (Clockwise) CCW (Counter-clockwise) Specifies the direction to count up. CW: Count ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z314-e1-05_fq-ms12.pdf

PDF[Z376-E1-06] MX-Z2000H series Fiber Laser Marker S...

...m Visible laser Laser medium Semiconductor laser - Maximum output 1 mW - Laser oscillation type CW (continuous wave) - Class 2 - 14 Fiber Laser Marker MX-Z2000H series Setup Manual (Z376) ■ S...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z376-e1-06_mx-z2000h.pdf

PDF[Z377-E1-06] MX-Z2000H series Fiber Laser Marker U...

...m Visible laser Laser medium Semiconductor laser - Maximum output 1 mW - Laser oscillation type CW (continuous wave) - Class 2 - Fiber Laser Marker MX-Z2000H series User’s Manual (Z377) 13 ■ ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z377-e1-06_mx-z2000h.pdf

PDFCSM_CJ1M-CPU2__DS_C_6_1 1 400-820-4535 www.fa.omro...

...入) −−−−−− 输出通用输出−−−−−−−−−−通用输出0 通用输出1 通用输出2 通用输出3 通用输出4 通用输出5 脉冲输出 CW/ CCW输出 −−−−−−−−−− 脉冲输出0 (CW) 脉冲输出0 (CCW) 脉冲输出1 (CW) ...

https://www.fa.omron.com.cn/data_pdf/closed/cat/cj1m-cpu2__ds_c_6_1_discon.pdf

PDFCSM_CJ1M-CPU2_DS_E_5_4 1 CJ-series CJ1M CPU Units ...

...t 2 General- purpose output 3 General- purpose output 4 General- purpose output 5 Pulse outputs CW/ CCW outputs −−−−−−−−−− Pulse output 0 (CW) Pulse output 0 (CCW) Pulse output ...

https://www.fa.omron.com.cn/data_pdf/closed/cat/cj1m-cpu2_ds_e_5_4_csm2075.pdf

PDF»设备开发效率提升 »通信方式更为灵活 »技术进步促进创新 CJ2系列

...脉冲I/O模块机型确定。 ) 正常输出最多12(每脉冲I/O模块6个) 脉冲输出最多4(每脉冲I/O模块2个) 输出方式:CW/CCW或脉冲+方向(此方式由I/O布线和梯形程序中使用的指令确定。 ) 输出频率:1pps~100kp...

https://www.fa.omron.com.cn/data_pdf/closed/cat/cj2h_cj2m_ca_c_17_15_discon.pdf

PDF»Faster machine development »Flexibility in commun...

...s 12 max. (6 per Pulse I/O Module) Pulse Outputs 4 max. (2 per Pulse I/O Module) Output method: CW/CCW or pulse + direction (The method is determined by the I/O wiring and the instructions us...

https://www.fa.omron.com.cn/data_pdf/closed/cat/cj2h_cj2m_p059-e1_17_27_csm1004123.pdf