D4C-1603

Enclosed Switch

Image

General-purpose Limit switches, General load, IP67, SPDT, Cross roller plunger, SJT(O) cable approved by UL and CSA 3 m

Shape/Structure General-purpose Limit switches
Actuator Cross roller plunger
Electrical ratings 5 A at 250 VAC/ 4 A at 30 VDC
Contact form SPDT
Cable specifications SJT(O) cable approved by UL and CSA、3 m
Degree of protection IP67

Item list of D4C

  • Ratings / Performance
Service lifeGeneral type
ctuatorCross roller plunger 12 dia. x 5
Sintered stainless steel roller
Electrical ratings5 A at 250 VAC/ 4 A at 30 VDC
Frequency50/60 Hz
Contact formSPDT
LoadGeneral load
Ratings (AC): Non-Inductive loadResistive load (NC): 5 A at 125 VAC、5 A at 250 VAC
Resistive load (NO): 5 A at 125 VAC、5 A at 250 VAC
Lamp load (NC): AC125V 1.5A、1 A at 250 VAC
Lamp load (NO): 7 A at 125 VAC、0.5 A at 250 VAC
Inductive load (NC): 3 A at 125 VAC、2 A at 250 VAC
Motor load (NC): 2.5A at 125 VAC、1.5 A at 250 VAC
Motor load (NO): 1.3 A at 125 VAC、0.8 A at 250 VAC
Ratings (DC): Non-Inductive loadResistive load (NC): 8 VDC 5 A、14 VDC 5 A、4 A at 30 VDC、125 VDC 0.4 A、250 VDC 0.2 A
Resistive load (NO): 8 VDC 5 A、14 VDC 5 A、4 A at 30 VDC、125 VDC 0.4 A、250 VDC 0.2 A
Lamp load (NC): 8 VDC 2 A、14 VDC 2 A、2 A at 30 VDC、0.05 A at 125 VDC、0.03 A at 250 VDC
Lamp load (NO): 8 VDC 2 A、14 VDC 2 A、2 A at 30 VDC、0.05 A at 125 VDC、0.03 A at 250 VDC
Inductive load (NC): 8 VDC 5 A、4 A at 14 VDC、3 A at 30 VDC、125 VDC 0.4 A、250 VDC 0.2 A
Motor load (NC): 3 A at 8 VDC、3 A at 14 VDC、3 A at 30 VDC、0.05 A at 125 VDC、0.03 A at 250 VDC
Motor load (NO): 3 A at 8 VDC、3 A at 14 VDC、3 A at 30 VDC、0.05 A at 125 VDC、0.03 A at 250 VDC
Inrush currentNC: 20 A
NO: 10 A
Earth terminalWith earth wire
Cable specificationsSJT(O) cable approved by UL and CSA、3 m
Ambient temperature使用時: -10 to 70℃
Ambient humidity35 to 95%
Permissible operating speed0.1 mm/s to 0.5 m/s
Permissible operating frequencyElectrical: 30 operations / 1 minute max.
Mechanical: 120 operations / 1 minute max.
Contact resistance (Initial value)300 mΩ max.
Insulation resistance100 MΩ min.
: at 500 VDC
Dielectric strengthBetween each terminal of the same polarities: 1000 VAC 50/60 Hz 1 min
Between live-metallic part and ground: 1,500 VAC 50/60 Hz for 1 min
Between each terminal and non-live-metallic part: 1,500 VAC 50/60 Hz for 1 min
Impulse withstand voltageBetween live-metallic part and ground: 2.5 kV
Between each terminal and non-live-metallic part: 2.5 kV
DurabilityElectrical: 200,000 operations min. (5 A at 125 VAC)
Mechanical: 10 million operations min.
Vibration resistanceMalfunction: 10 to 55 Hz, 1.5 mm double amplitude
Shock resistanceDestruction: Max. 1000 m/s**2
Malfunction: Max. 500 m/s**2
Pollution degree3 (EN60947-5-1)
Degree of protectionIP67
Classification of protection against electric shockClass I (with earth wire)
Operating Force (OF)Standard value 11.77 N max.
Release Force (RF)Standard value 4.41 N min.
Pre-Travel (PT)Standard value 1.8 mm max.
Movement Differential (MD)Standard value 0.2 mm max.
Over-Travel (OT)Standard value 3 mm min.
Operating Position (OP)Standard value 28.5±1 mm
  • Dimensions

Mounting hole dimensions

  • Circuits configuration

  • Characteristic chart

Durability curve

Electrical

Series

Enclosed Switch

D4C

about this Product