 FAQ00743 for Level Switches | OMRON Industrial Aut... FAQ00743 for Level Switches | OMRON Industrial Aut...
- ...N: PS-3S: F03-06: F03-05 3P: F03-07: F03-08: F03-09: F03-10: 1pc 1pc 3pcs 3m 4pcs 2pcs 2pcs 1pc 61F-G[]N Improved Design for a More Lightweight Construction and Reduced Standby Power Consumpt...https://www.ia.omron.com/support/faq/answer/33/faq00743/ 
 faq00746 faq00746
- ...: When interconnecting Electrode terminals of 61F with switches, be sure to use Basic Switches. 61F-G[]N Improved Design for a More Lightweight Construction and Reduced Standby Power Consumpt...https://www.ia.omron.com/support/faq/answer/33/faq00746/ 
 FAQ00751 for Level Switches | OMRON Industrial Aut... FAQ00751 for Level Switches | OMRON Industrial Aut...
- ...Ω model also available), use K7L Liquid Leakage Sensor or E7A Level Switch or E7M Level Switch. 61F-G[]N Improved Design for a More Lightweight Construction and Reduced Standby Power Consumpt...https://www.ia.omron.com/support/faq/answer/33/faq00751/ 
 faq00752 faq00752
- ...y capacitance increases with thick cable diameters, which shortens the applicable cable length. 61F-G[]N Improved Design for a More Lightweight Construction and Reduced Standby Power Consumpt...https://www.ia.omron.com/support/faq/answer/33/faq00752/ 
 faq00755 faq00755
- ...ods may bend from the force of the water. For applications involving tap water, use separators. 61F-G[]N Improved Design for a More Lightweight Construction and Reduced Standby Power Consumpt...https://www.ia.omron.com/support/faq/answer/33/faq00755/ 
 FAQ00759 for Level Switches | OMRON Industrial Aut... FAQ00759 for Level Switches | OMRON Industrial Aut...
- ...y about 8 VAC and 1 mA, so it is best to use a float switch contact that is for a minimal load. 61F-G[]N Improved Design for a More Lightweight Construction and Reduced Standby Power Consumpt...https://www.ia.omron.com/support/faq/answer/33/faq00759/ 
 FAQ00761 for Level Switches | OMRON Industrial Aut... FAQ00761 for Level Switches | OMRON Industrial Aut...
- ...electrode is acceptable. Figure 1: Example of a Loop Circuit Figure 2: Synchronizing the Phases 61F-G[]N Improved Design for a More Lightweight Construction and Reduced Standby Power Consumpt...https://www.ia.omron.com/support/faq/answer/33/faq00761/ 
 faq00765 faq00765
- ...ower indicator. It lights only when 61F is operating (when it is detecting the liquid surface). 61F-G[]N Improved Design for a More Lightweight Construction and Reduced Standby Power Consumpt...https://www.ia.omron.com/support/faq/answer/33/faq00765/ 
 FAQ00844 for Level Switches | OMRON Industrial Aut... FAQ00844 for Level Switches | OMRON Industrial Aut...
- ... and operate improperly. Also, be sure to check that the common electrode is grounded properly. 61F-G[]N Improved Design for a More Lightweight Construction and Reduced Standby Power Consumpt...https://www.ia.omron.com/support/faq/answer/33/faq00844/ 
 FAQ00848 for Level Switches | OMRON Industrial Aut... FAQ00848 for Level Switches | OMRON Industrial Aut...
- ... water and pure water, its specific resistance becomes higher. Oil cannot be used with the 61F. 61F-G[]N Improved Design for a More Lightweight Construction and Reduced Standby Power Consumpt...https://www.ia.omron.com/support/faq/answer/33/faq00848/