Primary Contents

Site Search Results

Site Search Product Search IA Global Search
Results 1311 - 1320 of 13551
EE-SX674P | OMRON Industrial Automation
...urrent consumption 12 mA (L terminal open) Control output Output type PNP open collector output Load power supply voltage 5 to 24 VDC Load curren 50 mA max. Residual voltage at 50 mA...

https://www.ia.omron.com/product/item/2238/

EE-SX674R | OMRON Industrial Automation
...urrent consumption 12 mA (L terminal open) Control output Output type PNP open collector output Load power supply voltage 5 to 24 VDC Load curren 50 mA max. Residual voltage at 50 mA...

https://www.ia.omron.com/product/item/2240/

EE-SX675 | OMRON Industrial Automation
...urrent consumption 12 mA (L terminal open) Control output Output type NPN open collector output Load power supply voltage 5 to 24 VDC Load curren 100 mA max. Residual voltage at 100 ...

https://www.ia.omron.com/product/item/2242/

EE-SX675P | OMRON Industrial Automation
...urrent consumption 12 mA (L terminal open) Control output Output type PNP open collector output Load power supply voltage 5 to 24 VDC Load curren 50 mA max. Residual voltage at 50 mA...

https://www.ia.omron.com/product/item/2243/

EE-SX676 | OMRON Industrial Automation
...urrent consumption 12 mA (L terminal open) Control output Output type NPN open collector output Load power supply voltage 5 to 24 VDC Load curren 100 mA max. Residual voltage at 100 ...

https://www.ia.omron.com/product/item/2246/

EE-SX676P | OMRON Industrial Automation
...urrent consumption 12 mA (L terminal open) Control output Output type PNP open collector output Load power supply voltage 5 to 24 VDC Load curren 50 mA max. Residual voltage at 50 mA...

https://www.ia.omron.com/product/item/2247/

EE-SX677 | OMRON Industrial Automation
...urrent consumption 12 mA (L terminal open) Control output Output type NPN open collector output Load power supply voltage 5 to 24 VDC Load curren 100 mA max. Residual voltage at 100 ...

https://www.ia.omron.com/product/item/2250/

EE-SX677P | OMRON Industrial Automation
...urrent consumption 12 mA (L terminal open) Control output Output type PNP open collector output Load power supply voltage 5 to 24 VDC Load curren 50 mA max. Residual voltage at 50 mA...

https://www.ia.omron.com/product/item/2251/

MY2-02 DC100/110 | OMRON Industrial Automation
... 9.1 mA 110 VDC 10 mA Contact form DPDT Contact method Single Contact material Ag Contact rated load 220 VAC 5 A (Resistive load) 220 VAC 2 A (Inductive load (cosφ = 0.4)) 2...

https://www.ia.omron.com/product/item/22968/

MY2-D DC48 | OMRON Industrial Automation
...il surge killer Diode Contact form DPDT Contact method Single Contact material Ag Contact rated load 220 VAC 5 A (Resistive load) 220 VAC 2 A (Inductive load (cosφ = 0.4)) 2...

https://www.ia.omron.com/product/item/22969/

Results 1311 - 1320 of 13551