CSM_G3R-I/O_DS_E_5_11 1 I/O Solid State Relays G3R...- ...ns. Terminal Arrangement/ Internal Connection Diagram (Top View) 39.5±0.1 10.5 78.5 max. 5-M3X8 61 max. 35.5 39.5 48 max. 2 (42.3) (35.8) 31 max. 3.5-dia. hole 16 max. M3 or 3.5-dia. hole 3.2...
https://www.ia.omron.com/data_pdf/cat/g3r-i_o_ds_e_5_11_csm2416.pdf
CSM_G3RZ_DS_E_5_2 1 Power MOS FET Relays G3RZ- ...de. Terminal Arrangement/ Internal Connection Diagram (Top View) 39.5±0.1 10.5 78.5 max. 5-M3X8 61 max. 35.5 39.5 48 max. 2 (42.3) (35.8) 31 max. 3.5-dia. hole 16 max. M3 or 3.5-dia. hole 3.2...
https://www.ia.omron.com/data_pdf/cat/g3rz_ds_e_5_2_csm2422.pdf
CSM_G6B-4__ND_G3S4_DS_E_5_1 1 Terminal Relay/Termi...- ... 16, M3.5 Phillips head screws IN side 43 max. 28 max. 78 max. IN side OUT side IN side 43 max. 61 max. 24 max. Five, M3 flat screws IN side OUT side IN side 43 max. 60 max. Note: Do not reve...
https://www.ia.omron.com/data_pdf/cat/g6b-4__nd_g3s4_ds_e_5_1_csm1057979.pdf
1 I/O Terminal Socket G70A 16-point I/O Terminal S...- ...O terminals: 1,000 MΩ(at 500 V) Other: 100 MΩ(at 500 V) Vibration resistance Malfunction: 10 to 61.2 to 10 Hz, 0.1-mm single amplitude (0.2-mm double amplitude); 61.2 to 150 to ...
https://www.ia.omron.com/data_pdf/cat/g70a_j087-e1_1_10_csm1057151.pdf
1 I/O Relay Terminal G70V I/O Relay Terminals with...- ...13 14 15 16 17 18 10 20 9 19 11 14 12 21 24 22 31 34 32 41 44 42 51 54 52 61 64 62 71 74 72 81 84 82 11 14 12 21 24 22 31 34 32 41 44 42 51 54 52 61 64 62 71 74 72 81 84 82 V G V G C...
https://www.ia.omron.com/data_pdf/cat/g70v_j215-e1_2_22.pdf
CSM_G7S-_-E_DS_E_7_3 1 Relays with Forcibly Guided...- ...s to terminals 41−42 or 43−44, pole 5 refers to terminals 51−52, and pole 6 refers to terminals 61−62. *6.The durability is for an ambient temperature of 15 to 35°C and an ambient humidity of...
https://www.ia.omron.com/data_pdf/cat/g7s-_-e_ds_e_7_3_csm1272.pdf
1 Relays with Forcibly Guided Contacts G7SA- ...2.5-@@ A1 A2 (1) (0) 12 44 24 34 11 43 23 33 A1 A2 (1) (0) 12 44 22 34 11 43 21 33 (4) 3.4 35.4 61 35.4 4.5 22.5 100 Operation indicator G7SA-3A1B Mounted Terminals Arrangement/Internal Conne...
https://www.ia.omron.com/data_pdf/cat/g7sa_j120-e1_12_14_csm1269.pdf
1 Power Relays G7Z Compact Electromagnetic Contact...- ...ry Contact Block 53 54 63 64 7 5 3 1 A1 8 6 4 2 A2 G7Z-4A-20Z-R G7Z-4A-11Z-R G7Z-4A-02Z-R 53 54 61 62 7 5 3 1 A1 8 6 4 2 A2 51 52 61 62 7 5 3 1 A1 8 6 4 2 A2 Note: The coil has no po...
https://www.ia.omron.com/data_pdf/cat/g7z_j160-e1_10_1_csm1001495.pdf
1 Safety Relay Unit with negative common (NPN)- ... 41-42. G9SA-501-P: Safety Output Contacts 13-14, 23-24, 33-34, 43-44, 53-54. Auxiliary Contact 61-62. G9SA-321-T@-P: Safety Output Contacts 13-14, 23-24, 33-34. Safety OFF-delay Output Conta...
https://www.ia.omron.com/data_pdf/cat/g9sa-p_f106-e1_6_2_csm1070131.pdf
CSM_G9SA_DS_E_11_15 1 Safety Relay Unit G9SA- ... Delay Timer 6 6 JP JP 123456 123456 123456 A1 13 23 33 41 A2 T11 T12 T31 T32 A1 13 23 33 43 53 61 A2 T11 T12 T31 T32 A1 13 23 33 43 53 61 A2 T11 T12 T31 T32 14 A PE T21 T23 T22 B243...
https://www.ia.omron.com/data_pdf/cat/g9sa_ds_e_11_15_csm1281.pdf