Sensors Switches Safety Components Relays Control ...- ... the sensing bands together? 1. The possible lengths of sensor cable for a Water Leak Detector (61F-GPN-V50/61F-WL) for different lengths of Sensing Bands (F03-15, -16PE, -16PT) are shown bel...
https://www.ia.omron.com/data_pdf/guide/33/levelapparatus_tg_e_8_2.pdf
Sensors Switches Safety Components Relays Control ...- ...d refer to the following table. Connected Devices •K7L-series Liquid Leakage Sensor Amplifiers •61F-GPN-V50/61F-WL series Water Leak Detectors Table 1: Sensing Band Wiring Distances (Includin...
https://www.ia.omron.com/data_pdf/guide/48/leakagesensor_tg_e_2_2.pdf
1 Water Leak Detector 61F-WL Set Sensitivity Freel...- ...ign/inventory management easy •Easy to replace during maintenance due to compatibility with the 61F-GPN-V50 series Model Number Legend Ordering Information Accessories (Order Separately) C...
https://www.ia.omron.com/data_pdf/cat/61f-wl_n232-e1_2_3_csm1118893.pdf
1 Durable, Easy-to-handle Connecting- ...ckets Mounting Brackets Note: PFC-N8 Mounting Brackets are included with 61F-GP-N@, 61F-GP-N8@, 61F-GPN-V50, 61F-GPN-BT/-BC, and 61F-APN2 Controllers. DIN Rails Type Track-mounted Socket Back...
https://www.ia.omron.com/data_pdf/cat/connectionsocket_ds_e_4_1_csm13.pdf
CSM_F03-15_DS_E_2_2 1 Sensing Band F03-15- ... Block. 2. Not applicable to the K7L-UD. Can the K7L Amplifier be used as a replacement for the 61F-GPN-V50 Water Leakage Detector? Yes. Because the surge withstand capability is different, h...
https://www.ia.omron.com/data_pdf/cat/f03-15_ds_e_2_2_csm527.pdf
CSM_F03-16PE_DS_E_1_8 1 Sensing Band F03-16PE- ... Block. 2. Not applicable to the K7L-UD. Can the K7L Amplifier be used as a replacement for the 61F-GPN-V50 Water Leakage Detector? Yes. Because the surge withstand capability is different, h...
https://www.ia.omron.com/data_pdf/cat/f03-16pe_ds_e_1_8_csm525.pdf
CSM_F03-16SFC_DS_E_2_4 1 Sensing Band F03-16SFC- ...ge 2 Range 1 200 m Range 3 Range 3 Range 2 Range 2 Range 1 F03-16SFC 2 (2) Connection with 61F-GPN-V50 (IV Cable + Sensing Band) ···Can be used. Note: These values are possible provided...
https://www.ia.omron.com/data_pdf/cat/f03-16sfc_ds_e_2_4_csm529.pdf
1 Liquid Leakage Sensor Amplifiers K7L Series- ...erminal Block. 2. Not applicable to K7L. Can the K7L Amplifier be used as a replacement for the 61F-GPN-V50 or 61F-WL-CP@-NRA Water Leakage Detector? Yes. Because the surge withstand capabili...
https://www.ia.omron.com/data_pdf/cat/k7l_n211-e1_6_6_csm1050158.pdf