Primary Contents

Site Search Results

Site Search Product Search IA Global Search
Results 1991 - 2000 of 2036
G2R-[]-S (S) General-purpose Relay/Specifications ...
...(resistive) 10 A, 250 VAC (general use) 100 × 10 3 TV-3 (NO contact only) 25 × 10 3 G2R-2-S (S) DPDT 5 A, 30 VDC (resistive) 5 A, 250 VAC (general use) 100 × 10 3 TV-3 (NO contact only) 25 × ...

https://www.ia.omron.com/products/family/1731/specification.html

H3CR-H Solid-state Timer/Lineup | OMRON Industrial...
...il 15, 2013 Input Output Supply voltage S-series 11-pin models 8-pin models Without reset input DPDT 100 to 120 VAC --- H3CR-H8L 100-120AC S 200 to 240 VAC H3CR-H8L 200-240AC S 24 VAC/DC H3CR...

https://www.ia.omron.com/products/family/1891/lineup.html

H3CR-H Solid-state Timer/Specifications | OMRON In...
...et/Forced reset Pin type 8-pin 11-pin Input type --- No-voltage input Output type Relay output (DPDT) Relay output (SPDT) Relay output (DPDT) Mounting method DIN track mounting, surf...

https://www.ia.omron.com/products/family/1891/specification.html

H3CR-A Solid-state Multi-functional Timers/Specifi...
...age input Voltage input --- Time-limit output type H3CR-A/-A8/-AP/-A-301/-A8-301: Relay output (DPDT) H3CR-AS/-A8S: Transistor output (NPN/PNP universal) *1 Relay output (SPDT) Instantaneous ...

https://www.ia.omron.com/products/family/193/specification.html

H3CR-F Solid-state Timer/Specifications | OMRON In...
...ting/Reset method Time-limit operation/Time-limit reset or self-reset Output type Relay output (DPDT) Mounting method DIN track mounting, surface mounting, and flush mounting Approved standar...

https://www.ia.omron.com/products/family/194/specification.html

H3YN Solid-state Timer/Specifications | OMRON Indu...
...125 VDC: Relay ON: Approx. 1.6 W at 125 VDC Relay OFF: Approx. 0.4 W at 125 VDC Control outputs DPDT: 5 A at 250 VAC, resistive load (cosφ = 1) The minimum applicable load is 1 mA at 5 VDC (P...

https://www.ia.omron.com/products/family/197/specification.html

A3U Plateau Head Pushbutton Switch/Lineup | OMRON ...
...lor symbol LED SPDT 5 VDC A3UL-TB[]-1A1C-M W, A 12 VDC A3UL-TB[]-2A1C-M 24 VDC A3UL-TB[]-3A1C-M DPDT 5 VDC A3UL-TB[]-1A2C-M 12 VDC A3UL-TB[]-2A2C-M 24 VDC A3UL-TB[]-3A2C-M SPDT 5 VDC A3UL-TBG...

https://www.ia.omron.com/products/family/3194/lineup.html

D4A-[]N General-purpose Limit Switch/Lineup | OMRO...
...ntained Switches have a lock mechanism for the switch operation and thus use a Fork Lever Lock. DPDT, Double-break Switches Receptacle box G 1/2 Conduit Indicator Without indicator With neon ...

https://www.ia.omron.com/products/family/328/lineup.html

D4A-[]N General-purpose Limit Switch/Specification...
...C 125 VDC * 250 VDC * 10 10 6 0.8 0.4 6 6 4 0.2 0.1 3 3 3 0.2 0.1 10 10 6 0.8 0.4 6 6 4 0.2 0.1 DPDT double-break (without indicator) 125 VAC 250 VAC 480 VAC 600 VAC 5 3 1.5 1 2 1 0.5 0.4 4 2...

https://www.ia.omron.com/products/family/328/specification.html

K8AK-PH Phase-sequence Phase-loss Relay/Specificat...
...thod Automatic reset Indicators Power (PWR): Green, Relay output (RY): Yellow Output relays One DPDT relay (NC operation) Output relay ratings Rated load Resistive load 5 A at 250 VAC 5 A at ...

https://www.ia.omron.com/products/family/3380/specification.html

Results 1991 - 2000 of 2036