Primary Contents

Site Search Results

Site Search Product Search IA Global Search
Results 2251 - 2260 of 3336
E5AN-H, E5EN-H Advanced Digital Temperature Contro...
...hing Supported (number of banks: 8) Local SP, alarm settings, PID sets (PID constants, MV upper limit, MV lower limit, etc.) Other functions Manual output, heating/cooling control, l...

https://www.ia.omron.com/products/family/1947/specification.html

CJ1W-NC[][]3 CJ series Position Control Units/Spec...
...in input signal without using proximity input signal, or to stop upon origin input signal after limit input signal has turned OFF. N.O. = Normally open N.C. = Normally closed Jogging Jogging ...

https://www.ia.omron.com/products/family/1409/specification.html

CJ1W-NC[]71 CJ-series Position Control Unit with M...
...(10,000 command units/s2) Speed command range for speed control -199.999% to 199.999% The upper limit of the speed command range depends on the specifications of the Servo Drive. Torque comma...

https://www.ia.omron.com/products/family/1528/specification.html

E3S Photoelectric Sensor with Built-in Amplifier/S...
...nation is the illumination that changes the output ±20% at 200 lx. It is not the operational    limit. last update: December 2, 2021...

https://www.ia.omron.com/products/family/1568/specification.html

CJ1W-PTS CJ-series Process Analog I/O Unit/Specifi...
..., is given    below. The "full scale of electromotive force" is the difference between the high limit and low limit converted to    electromotive force for each thermocouple. CJ1W-PT...

https://www.ia.omron.com/products/family/1644/specification.html

CJ1W-PDC15 CJ-series Process Analog I/O Unit/Speci...
...ng of process value in industrial units, process value alarm setting (L, H), inrush input upper limit, inrush input upper limit time, zero/span adjustment value, Square root function...

https://www.ia.omron.com/products/family/1646/specification.html

E5CS Temperature Controllers/Lineup | OMRON Indust...
...There is no alarm output 2 mode switch. The default setting for alarm output 2 is for the upper limit alarm mode. To     change the setting, change the alarm type for alarm output 2 in initia...

https://www.ia.omron.com/products/family/166/lineup.html

CS1W-PMV SYSMAC CS-series Process Analog I/O Units...
...words/Unit CPU Unit to Analog Output Unit: Output hold for when CPU Unit error occurs, high/low limit values, rate-of-change limit values (positive and negative directions), number o...

https://www.ia.omron.com/products/family/1669/specification.html

CS1W-PPS01 SYSMAC CS-series Process Analog I/O Uni...
... sensors that are the pulse sources. Output voltage: 12 V DC ± 15% Current capacity: 30 mA max. Limit current when short-circuited: 31 to 55 mA Allowable short-circuit time: No limit...

https://www.ia.omron.com/products/family/1671/specification.html

CJ1W-SPU01-V2 CJ-series High-speed Data Storage Un...
...CPU Unit's I/O memory, the collected values can be scaled with a linear equation or upper/lower limit range before storage (unit version 1.2 or later). File size 2 GB per file Record size Spe...

https://www.ia.omron.com/products/family/1732/specification.html

Results 2251 - 2260 of 3336