K3HB-CNB-FLK3AT11 AC100-240 | OMRON Industrial Aut...
... 20 µs min. F3: 0 to 50 kHz ON/OFF pulse width of 9 µs min. Voltage level ON voltage: 4.5 to 30 V, OFF voltage: -30 to 2 V, input impedance: 10 kΩ Open collector F1: 0 to 30 kHz ON/O...

https://www.ia.omron.com/product/item/4423/

K3HB-CNB-L1AC21 AC100-240 | OMRON Industrial Autom...
... 20 µs min. F3: 0 to 50 kHz ON/OFF pulse width of 9 µs min. Voltage level ON voltage: 4.5 to 30 V, OFF voltage: -30 to 2 V, input impedance: 10 kΩ Open collector F1: 0 to 30 kHz ON/O...

https://www.ia.omron.com/product/item/4424/

K3HB-CNB-L1AT11 AC/DC24 | OMRON Industrial Automat...
... 20 µs min. F3: 0 to 50 kHz ON/OFF pulse width of 9 µs min. Voltage level ON voltage: 4.5 to 30 V, OFF voltage: -30 to 2 V, input impedance: 10 kΩ Open collector F1: 0 to 30 kHz ON/O...

https://www.ia.omron.com/product/item/4425/

K3HB-CNB-L1AT11 AC100-240 | OMRON Industrial Autom...
... 20 µs min. F3: 0 to 50 kHz ON/OFF pulse width of 9 µs min. Voltage level ON voltage: 4.5 to 30 V, OFF voltage: -30 to 2 V, input impedance: 10 kΩ Open collector F1: 0 to 30 kHz ON/O...

https://www.ia.omron.com/product/item/4426/

K3HB-CNB-L2AT11 AC/DC24 | OMRON Industrial Automat...
... 20 µs min. F3: 0 to 50 kHz ON/OFF pulse width of 9 µs min. Voltage level ON voltage: 4.5 to 30 V, OFF voltage: -30 to 2 V, input impedance: 10 kΩ Open collector F1: 0 to 30 kHz ON/O...

https://www.ia.omron.com/product/item/4427/

K3HB-CNB-L2AT11 AC100-240 | OMRON Industrial Autom...
... 20 µs min. F3: 0 to 50 kHz ON/OFF pulse width of 9 µs min. Voltage level ON voltage: 4.5 to 30 V, OFF voltage: -30 to 2 V, input impedance: 10 kΩ Open collector F1: 0 to 30 kHz ON/O...

https://www.ia.omron.com/product/item/4428/

K3HB-HTA-L1AC1 AC100-240 | OMRON Industrial Automa...
...c strength Between the entire external terminal and case: 2,300 VAC 1 min Noise immunity ±1,500 V at power supply terminals in normal or common mode (waveform with 1-ns rising edge and pulse ...

https://www.ia.omron.com/product/item/4434/

K3HB-HTA-L1AC2 AC100-240 | OMRON Industrial Automa...
...c strength Between the entire external terminal and case: 2,300 VAC 1 min Noise immunity ±1,500 V at power supply terminals in normal or common mode (waveform with 1-ns rising edge and pulse ...

https://www.ia.omron.com/product/item/4435/

K3HB-HTA-L2AC1 AC100-240 | OMRON Industrial Automa...
... 10 VDC Allowable load impedance: 5 kΩ min. Resolution: Approx. 10000 Output error: ±0.5% FS (1 V or less: ±0.15 V, not output for 0 or less) Display Display method Negative LCD (bac...

https://www.ia.omron.com/product/item/4436/

K3HB-PPB-A1 AC/DC24 | OMRON Industrial Automation
...method Terminal blocks Contact ON: 1 kΩ max. OFF: 100 kΩ min. No-contact ON residual voltage: 2 V max. OFF leakage current: 4 mA max. Maximum applied voltage: 30 V max.DC Leakage cur...

https://www.ia.omron.com/product/item/4457/