E6C3-A Slim Encoder with Diameter of 50 mm/Specifi...
...4 Output code increases for CW (as viewed from end of shaft). Switched using rotation direction input. Strobe signal None Supported None Supported None Positioning signal None Supported None ...

https://www.ia.omron.com/products/family/1347/specification.html

DRT2-[]D04CL(-1) / []D08C(-1) / []D08CL(-1) / []D1...
...ight 340 g max. 390 g max. I/O power supply connector --- 7/8-16UN Communications connector M12 Input Specifications 8-point Inputs Terminals with Transistors Model DRT2-ID08C DRT2-ID08C-1 In...

https://www.ia.omron.com/products/family/1354/specification.html

CJ1W-NC[][]3 CJ series Position Control Units/Spec...
...Special I/O Unit I/O requirements Words 5 words 10 words 20 words Controlled driver Pulse-train input-type Servo Drive or stepping motor driver NC113/213/413 models have open collector output...

https://www.ia.omron.com/products/family/1409/specification.html

CJ1W-TC CJ Series Temperature Control Unit/Specifi...
...960 words) CIO 2000 to CIO 2959 20 words/Unit for constant data exchange (6 output words and 14 input words) CPU Unit to Temperature Control Unit Set point (SP) Operating commands RUN/STOP co...

https://www.ia.omron.com/products/family/1438/specification.html

DRT2-[]D08(-1) / []D16(-1) Transistor Remote I/O T...
...DRT2-ID08(-1)/OD08(-1): 135 g max. DRT2-MD16(-1): 145 g max. DRT2-ID16(-1)/OD16(-1): 140 g max. Input Specifications 8-point Inputs Terminals with Transistors Model DRT2-ID08 DRT2-ID08-1 Inte...

https://www.ia.omron.com/products/family/146/specification.html

DRT2-AD04(H) / DA02 Analog I/O Terminals/Specifica...
...crew tightening torque M3 (power, I/O terminal): 0.5 Nm Weight 170 g max. 160 g max. 150 g max. Input Specifications Model DRT2-AD04 DRT2-AD04H Specifications Voltage input Curr...

https://www.ia.omron.com/products/family/147/specification.html

DRT2-[]D32ML(-1) / []D16ML(-1) MIL Connector Termi...
...x. * * The Connector Cable provided with the DRT2-ID16MLX(-1) and DRT2-OD16MLX(-1) is 10 g max. Input Specifications 32-point Inputs Terminals with Connectors Model DRT2-ID32ML DRT2-ID32ML-1 ...

https://www.ia.omron.com/products/family/1487/specification.html

DRT2-[]D16SL(H)(-1) / []D32SLH(-1) Screw-less Clam...
...track mounting Weight 480 g max. I/O Specifications 16-point Inputs Terminals with Transistors (Input Specifications) Model DRT2-ID16SL DRT2-ID16SL-1 DRT2-ID16SLH DRT2-ID16SLH-1 Internal I/O ...

https://www.ia.omron.com/products/family/1488/specification.html

G9SX-AD[] / BC / EX Flexible Safety Unit (Advanced...
...ary 10, 2013 Advanced Unit Safety outputs *3 Auxiliary outputs *4 Logical AND connection No. of input chan- nels Max. OFF- delay time *1 Rated volt- age Ter- minal block type Model Instan- ta...

https://www.ia.omron.com/products/family/1524/lineup.html

G9SX-AD[] / BC / EX Flexible Safety Unit (Advanced...
...Index Features Lineup Specifications Dimensions Catalog last update: July 5, 2021 Ratings Power input Model G9SX-AD322-[]/ADA222-[] G9SX-BC202-[] G9SX-EX-[] Rated supply voltage 24 VDC Operat...

https://www.ia.omron.com/products/family/1524/specification.html