Primary Contents

Site Search Results

Site Search Product Search IA Global Search
Results 3561 - 3570 of 4795
G3RV-ST700-D AC200 | OMRON Industrial Automation
...nt resistivity 30 A (10 ms) Permissible I2**t 9 A 2 s Applicable load Load carrying capacity 72 W (Output voltage: 24 VDC) Performance Operate time 6 ms max. Release time 21 ms max.(1 cycle o...

https://www.ia.omron.com/product/item/73154/

G3RV-ST700-D AC230 | OMRON Industrial Automation
...nt resistivity 30 A (10 ms) Permissible I2**t 9 A 2 s Applicable load Load carrying capacity 72 W (Output voltage: 24 VDC) Performance Operate time 6 ms max. Release time 21 ms max.(1 cycle o...

https://www.ia.omron.com/product/item/73155/

G3RV-ST700-D DC12 | OMRON Industrial Automation
...nt resistivity 30 A (10 ms) Permissible I2**t 9 A 2 s Applicable load Load carrying capacity 72 W (Output voltage: 24 VDC) Performance Operate time 6 ms max. Release time 21 ms max.(1 cycle o...

https://www.ia.omron.com/product/item/73156/

G3RV-ST700-D DC24 | OMRON Industrial Automation
...nt resistivity 30 A (10 ms) Permissible I2**t 9 A 2 s Applicable load Load carrying capacity 72 W (Output voltage: 24 VDC) Performance Operate time 6 ms max. Release time 21 ms max.(1 cycle o...

https://www.ia.omron.com/product/item/73157/

G3RV-ST700-D-H AC/DC24 | OMRON Industrial Automati...
...nt resistivity 30 A (10 ms) Permissible I2**t 9 A 2 s Applicable load Load carrying capacity 72 W (Output voltage: 24 VDC) Performance Operate time 3 ms max. Release time 21 ms max.(1 cycle o...

https://www.ia.omron.com/product/item/73158/

G3RV-ST700-D-H DC24 | OMRON Industrial Automation
...nt resistivity 30 A (10 ms) Permissible I2**t 9 A 2 s Applicable load Load carrying capacity 72 W (Output voltage: 24 VDC) Performance Leakage current 10 µA max. (at 24 VDC) Insulation resist...

https://www.ia.omron.com/product/item/73159/

MY4F AC200/220 | OMRON Industrial Automation
...DC: 3 A Maximum switching power 660 VA (Resistive load) 176 VA (Inductive load (cosφ = 0.4)) 72 W (Resistive load) 36 W (Inductive load (L/R = 7 ms)) Contact form 4PDT Contact method...

https://www.ia.omron.com/product/item/7469/

MY4F AC24 | OMRON Industrial Automation
...DC: 3 A Maximum switching power 660 VA (Resistive load) 176 VA (Inductive load (cosφ = 0.4)) 72 W (Resistive load) 36 W (Inductive load (L/R = 7 ms)) Contact form 4PDT Contact method...

https://www.ia.omron.com/product/item/7470/

MY4F DC100/110 | OMRON Industrial Automation
...se voltage (Reset voltage) 10 % min. Maximum voltage 110 % (23 ℃) Power consumption Approx. 0.9 W Contact Contact rated load 220 VAC 3 A (Resistive load) 220 VAC 0.8 A (Inductive load (cosφ =...

https://www.ia.omron.com/product/item/7471/

MY4F DC12 | OMRON Industrial Automation
...se voltage (Reset voltage) 10 % min. Maximum voltage 110 % (23 ℃) Power consumption Approx. 0.9 W Contact Contact rated load 220 VAC 3 A (Resistive load) 220 VAC 0.8 A (Inductive load (cosφ =...

https://www.ia.omron.com/product/item/7472/

Results 3561 - 3570 of 4795