CJ1W-TC CJ Series Temperature Control Unit/Lineup ...
...rent consumption (A) Model Stand- ards No. of loops Temperature sensor inputs Control outputs 5 V 24 V CJ1 Special I/O Units Temperature Control Units 4 loops Thermocouple input (R, ...

https://www.ia.omron.com/products/family/1438/lineup.html

S8T-DCBU-02 Buffer Block/Lineup | OMRON Industrial...
...Output voltage (during backup operation) Output current Model number 24 VDC (24 to 28 VDC) 22.5 V 2.5 A S8T-DCBU-02 Options (Order Separately) Bus Line Connector (Connects to Buffer Block) Ty...

https://www.ia.omron.com/products/family/1466/lineup.html

S8T-DCBU-02 Buffer Block/Specifications | OMRON In...
...o 28 VDC Current Charging 0.4 A Standby 0.18 A Output *1 Backup operation Output voltage For 24 V: 22.5 V typ., 22.0 V min. For 28 V: 26.4 V typ., 25....

https://www.ia.omron.com/products/family/1466/specification.html

E4PA-N Ultrasonic Displacement Sensor/Specificatio...
...tput Current output: 4 to 20 mA (Allowable load resistance: 500 Ω max.) Voltage output: 0 to 10 V (1,000 Ω min.) Protective circuit Load short-circuit protection, mutual interference preventi...

https://www.ia.omron.com/products/family/1467/specification.html

DRT2-[]D16TA(-1) Transistor Remote I/O Terminals w...
...TA-1 Internal I/O common NPN PNP I/O points 16 inputs ON voltage 15 VDC min. (between input and V terminal) 15 VDC min. (between input and G terminal) OFF voltage 5 VDC max. (between input an...

https://www.ia.omron.com/products/family/1486/specification.html

D4N Safety Limit Switch/Specifications | OMRON Ind...
...) Item AC-15 DC-13 Rated operating current (I e ) 3 A 0.27 A Rated operating voltage (U e ) 240 V 250 V Note: Use a 10 A fuse type gI or gG that conforms to IEC60269 as a short-circu...

https://www.ia.omron.com/products/family/1497/specification.html

G3ZA Multi-channel Power Controller/Specifications...
...tor, one output Max. applicable voltage: 30 VDC, Max. load current: 50 mA Residual voltage: 1.5 V max., Leakage current: 0.4 mA max. Indications LED indicators Control method Optimum cycle co...

https://www.ia.omron.com/products/family/1511/specification.html

CJ1W-NC[]71 CJ-series Position Control Unit with M...
...bers allocated Current consumption (A) Model Stand- ards Control output interface No. of axes 5 V 24 V CJ1 CPU Bus Units Position Control Unit with MECHATROLINK- II interface Control...

https://www.ia.omron.com/products/family/1528/lineup.html

CJ1W-INT01 CJ-series Interrupt Input Units/Lineup ...
...urrent Commons Input pulse width conditions Max. Units mountable per Unit External connection 5 V 24 V Interrupt Input Unit 16 inputs 24 VDC, 7 mA 16 points, 1 common ON time: 0.05 m...

https://www.ia.omron.com/products/family/1642/lineup.html

CJ1W-IDP01 CJ-series Quick-response Input Units/Li...
...del I/O points Input voltage current Commons Input pulse width conditions External connection 5 V 24 V Quick- response Input Unit 16 inputs 24 VDC, 7 mA 16 points, 1 common ON time: ...

https://www.ia.omron.com/products/family/1643/lineup.html