H3DT-N / -L Multi-range, Multi-mode Timer/Specific...
...evel: 0 to 2.4 VAC/DC *3 Power consumption H3DT-N2/-L2 At 240 VAC: 2.3 VA max., at 240 VDC: 1.0 W max., at 24 VDC: 0.3 W max. H3DT-N1/-L1 At 240 VAC: 2.0 VA max., at 240 VDC: 0....

https://www.ia.omron.com/products/family/3486/specification.html

H3DT-A Power ON-delay Timer/Specifications | OMRON...
...tage 10% of rated voltage *3 Power consumption H3DT-A2 At 240 VAC: 2.2 VA max., at 240 VDC: 0.7 W max., at 24 VDC: 0.3 W max. H3DT-A1 At 240 VAC: 1.8 VA max., at 240 VDC: 0.6 ...

https://www.ia.omron.com/products/family/3487/specification.html

H3DT-G Star-delta Timer/Specifications | OMRON Ind...
...age 10% of rated voltage Power consumption H3DT-N2/-L2 At 240 VAC: 1.9 VA max., at 240 VDC: 0.6 W max., at 24 VDC: 0.3 W max. Rated Insulation Voltage 250 V Control output Contact ou...

https://www.ia.omron.com/products/family/3489/specification.html

H3DT-H Power OFF-delay Timer/Specifications | OMRO...
... VA max. H3DT-HDL At 240 VAC: 21.7 VA max. H3DT-HBS/-HBL At 48 VAC: 1.0 VA max., at 24 VDC: 0.4 W max. Timer operation starting voltage 30% or less of power supply voltage Rated Insulation Vo...

https://www.ia.omron.com/products/family/3490/specification.html

K8DT-AS Single-phase Current Relay/Specifications ...
...AC 50/60 Hz, 24 VDC K8DT-AS[][]A: 100 to 240 VAC 50/60 Hz Power consumption 24 VAC/DC: 1.8 VA/1 W max. 100 to 240 VAC: 2.5 VA max. Rated insulation voltage 600 VAC Operating value setting ran...

https://www.ia.omron.com/products/family/3491/specification.html

K8DT-AW Single-phase Overcurrent/Undercurrent Rela...
... VAC 50/60Hz, 24 VDC K8DT-AW[][]A: 100 to 240 VAC 50/60Hz Power consumption 24 VAC/DC: 1.8 VA/1 W max. 100 to 240 VAC: 2.5 VA max. Rated insulation voltage 600 VAC Operating value setting ran...

https://www.ia.omron.com/products/family/3492/specification.html

K8DT-VS Single-phase Voltage Relay/Specifications ...
... VAC 50/60Hz, 24 VDC K8DT-VS[][]A: 100 to 240 VAC 50/60Hz Power consumption 24 VAC/DC: 1.8 VA/1 W max. 100 to 240 VAC: 2.5 VA max. Rated insulation voltage 600 VAC Operating value setting ran...

https://www.ia.omron.com/products/family/3493/specification.html

K8DT-VW Single-phase Overvoltage/Undervoltage Rela...
...AC 50/60 Hz, 24 VDC K8DT-VW[][]A: 100 to 240 VAC 50/60 Hz Power consumption 24 VAC/DC: 1.8 VA/1 W max. 100 to 240 VAC: 2.5 VA max. Rated insulation voltage 600 VAC Operating value setting ran...

https://www.ia.omron.com/products/family/3494/specification.html

K8DT-LS Conductive Level Controller/Specifications...
...0/60 Hz Voltage across electrodes 5 V p-p (Approx. 20 Hz) Power consumption 24 VAC/DC: 1.8 VA/1 W max. 100 to 240 VAC: 2.5 VA max. Rated insulation voltage 253 VAC Operating resistance 10 to ...

https://www.ia.omron.com/products/family/3495/specification.html

K8DT-TH Temperature Monitoring Relay/Specification...
...ange 85% to 110% of power supply voltage Power consumption 24 VAC or 24 VDC: 2.1 VA max. or 1.2 W max. 100 to 240 VAC: 3.1 VA max. Rated insulation voltage 253 VAC Sensor inputs K8DT-TH1 Ther...

https://www.ia.omron.com/products/family/3499/specification.html