faq02666- ... distance between Proximity Sensors and F92A will need to be reduced by half. Figure 1 Figure 2 E2E Standard Sensors for Detecting Ferrous Metals under Standard Conditions What kind of consid...
https://www.ia.omron.com/support/faq/answer/41/faq02666/
faq02670- ...e inappropriate for transmissions with F92A. The following Proximity Sensors are transmittable. E2E-X5E1, -X5E2, -X5Y1, -X5Y2 E2F-X5E1, -X5E2, -X5F1, -X5F2, -X5Y1, -X5Y2 E2E Standard...
https://www.ia.omron.com/support/faq/answer/41/faq02670/
faq03386- ...ection cannot be performed. For stable detection, it is recommended to first ionize the object. E2E Standard Sensors for Detecting Ferrous Metals under Standard Conditions What kind of consid...
https://www.ia.omron.com/support/faq/answer/41/faq03386/
FAQ00227 for Photoelectric Sensors | OMRON Industr...- ...satisfied because the amount of light decreases. 2. Notes by the sensing methods are as follows E2E Standard Sensors for Detecting Ferrous Metals under Standard Conditions Can a Photoelectric...
https://www.ia.omron.com/support/faq/answer/43/faq00227/
FAQ00297 for Photoelectric Sensors | OMRON Industr...- ...d from Photoelectric Sensor of different place intersects? Answer There is no problem at all. E2E Standard Sensors for Detecting Ferrous Metals under Standard Conditions Can a Photoelectric...
https://www.ia.omron.com/support/faq/answer/43/faq00297/
FAQ00307 for Photoelectric Sensors | OMRON Industr...- ...ource used for photoelectric sensors is four types that they are blue, green, red and infrared. E2E Standard Sensors for Detecting Ferrous Metals under Standard Conditions Can a Photoelectric...
https://www.ia.omron.com/support/faq/answer/43/faq00307/
FAQ00320 for Photoelectric Sensors | OMRON Industr...- ... detects the receiving light position of the reflected light, and steady detection is possible. E2E Standard Sensors for Detecting Ferrous Metals under Standard Conditions Can a Photoelectric...
https://www.ia.omron.com/support/faq/answer/43/faq00320/
FAQ00334 for Photoelectric Sensors | OMRON Industr...- ...h a tester. *This is simply operation check, and judges only the trouble of the control output. E2E Standard Sensors for Detecting Ferrous Metals under Standard Conditions Can a Photoelectric...
https://www.ia.omron.com/support/faq/answer/43/faq00334/
faq00335- ...1.4 m Note:Tape Reflectors (E39-RS1, E39-RS2, and E39-RS3) can be used cut to the desired size. E2E Standard Sensors for Detecting Ferrous Metals under Standard Conditions Can a Photoelectric...
https://www.ia.omron.com/support/faq/answer/43/faq00335/
FAQ00350 for Photoelectric Sensors | OMRON Industr...- ...t are findings when a Photoelectric Sensor is selected? Answer Please confirm below findings. E2E Standard Sensors for Detecting Ferrous Metals under Standard Conditions Can a Photoelectric...
https://www.ia.omron.com/support/faq/answer/43/faq00350/