Primary Contents

Site Search Results

Site Search Product Search IA Global Search
Results 421 - 430 of 588
FAQ01447 for Pressure Sensors | OMRON Industrial A...
...E8M-10 Pressure Sensor is ±1% F.S. Converted to voltage, ±1% × 1⁄100 (%) × 4 V (F.S.) = ±0.04 V E2E Standard Sensors for Detecting Ferrous Metals under Standard Conditions The zero-reset func...

https://www.ia.omron.com/support/faq/answer/35/faq01447/

faq03426
...to 2.00 kPa or 5.00 kPa whether above or below 1 kPa. Indication is not given in units of 1 Pa. E2E Standard Sensors for Detecting Ferrous Metals under Standard Conditions The zero-reset func...

https://www.ia.omron.com/support/faq/answer/35/faq03426/

faq00197
...n they are mounted facing each other or in parallel. Model Item M8 M12 M18 M30 DC 2-Wire Models E2E-X[]D[] AC/DC 2-Wire Models E2E-X[]T1 Shielded A 20 30 (20) 50 (30) 100 (50) B 15 2...

https://www.ia.omron.com/support/faq/answer/41/faq00197/

FAQ00201 for Proximity Sensors | OMRON Industrial ...
... the sensing object is far and the oscillation level is high when there is a surrounding metal. E2E Standard Sensors for Detecting Ferrous Metals under Standard Conditions What kind of consid...

https://www.ia.omron.com/support/faq/answer/41/faq00201/

faq00231
...rent frequencies are available to stagger the oscillating frequencies of the Proximity Sensors. E2E Standard Sensors for Detecting Ferrous Metals under Standard Conditions What kind of consid...

https://www.ia.omron.com/support/faq/answer/41/faq00231/

faq00233
...s? Answer  Refer to the following figures, which apply to Sensor A being affected by Sensor B. E2E Standard Sensors for Detecting Ferrous Metals under Standard Conditions What kind of consid...

https://www.ia.omron.com/support/faq/answer/41/faq00233/

FAQ00302 for Proximity Sensors | OMRON Industrial ...
...Question Please teach the principle of operation of Standard cylinder type Proximity Sensor the E2E Series. Answer  The circuit composition and the principle of operation are as follows. 1. ...

https://www.ia.omron.com/support/faq/answer/41/faq00302/

FAQ00308 for Proximity Sensors | OMRON Industrial ...
... moving direction of sensing object is parallel to the sensing surface of the proximity sensor. E2E Standard Sensors for Detecting Ferrous Metals under Standard Conditions What kind of consid...

https://www.ia.omron.com/support/faq/answer/41/faq00308/

faq00311
...ove Proximity Sensors cannot be used in a sereis connection. If needed, connect through relays. E2E-X[]Y For the above Proximity Sensors, the voltage VL that can be applied to the load when O...

https://www.ia.omron.com/support/faq/answer/41/faq00311/

faq00314
... electronic components, resin, and cables). Use Sensors within the specified temperature range. E2E Standard Sensors for Detecting Ferrous Metals under Standard Conditions What kind of consid...

https://www.ia.omron.com/support/faq/answer/41/faq00314/

Results 421 - 430 of 588