PDF1 Single-phase Current Relay K8AK-AS
... voltage Isolated power supply 24 VAC/DC 100 to 240 VAC Power consumption 24 VAC/DC: 2.0 VA/1.1 W max. 100 to 240 VAC: 4.6 VA max. Operating value setting range (SV) 10% to 100% of the maximu...

https://www.ia.omron.com/data_pdf/cat/k8ak-as_n179-e1_4_7_csm1020909.pdf

PDF1 Single-phase Overcurrent/Undercurrent Relay
... voltage Isolated power supply 24 VAC/DC 100 to 240 VAC Power consumption 24 VAC/DC: 2.0 VA/1.1 W max. 100 to 240 VAC: 4.6 VA max. Operating value setting range (SV) 10% to 100% of the maximu...

https://www.ia.omron.com/data_pdf/cat/k8ak-aw_n180-e1_4_8_csm1020910.pdf

PDF1 Conductive Level Controller K8AK-LS
...60 Hz Voltage across electrodes 5 V p-p (Approx. 20 Hz) Power consumption 24 VAC/DC: 2.0 VA/1.1 W max. 100 to 240 VAC: 4.6 VA max. Operating resistance 10 k to 100 kΩ(variable) Reset resistan...

https://www.ia.omron.com/data_pdf/cat/k8ak-ls_n188-e1_4_9_csm1020918.pdf

PDF1 Three-phase Asymmetry and Phase-sequence Phase-l...
...ated load Resistive load 5 A at 250 VAC 5 A at 30 VDC Maximum switching capacity: 1,250 VA, 150 W Minimum load: 5 VDC, 10 mA (reference values) Mechanical life: 10 million operations min. Ele...

https://www.ia.omron.com/data_pdf/cat/k8ak-pa_n186-e1_3_7_csm1020916.pdf

PDF1 Three-phase Voltage and Phase-sequence Phase-los...
...ated load Resistive load 5 A at 250 VAC 5 A at 30 VDC Maximum switching capacity: 1,250 VA, 150 W Minimum load: 5 VDC, 10 mA (reference values) Mechanical life: 10 million operations min. Ele...

https://www.ia.omron.com/data_pdf/cat/k8ak-pm_n185-e1_3_7_csm1020915.pdf

PDF1 Three-phase Voltage Relay K8AK-PW
...ated load Resistive load 5 A at 250 VAC 5 A at 30 VDC Maximum switching capacity: 1,250 VA, 150 W Minimum load: 5 VDC, 10 mA (reference values) Mechanical life: 10 million operations min. Ele...

https://www.ia.omron.com/data_pdf/cat/k8ak-pw_n184-e1_3_8_csm1020914.pdf

PDF1 Temperature Monitoring Relay K8AK-TH
...4 VDC Allowable voltage range 85% to 110% of power supply voltage Power consumption 5 VA max. 2 W max. (24 VDC), 4 VA max. (24 VAC) Sensor inputs K8AK-TH11S Thermocouple: K, J, T, E; Platinum...

https://www.ia.omron.com/data_pdf/cat/k8ak-th_n187-e1_4_7_csm1020917.pdf

PDF1 Thermistor Motor Protection Relay
... voltage Isolated power supply 24 VAC/DC 100 to 240 VAC Power consumption 24 VAC/DC: 1.8 VA/1.0 W max. 100 to 240 VAC: 3.5 VA max. Rated input voltage 3-phase, 200 to 480 VAC (3-wire) Operati...

https://www.ia.omron.com/data_pdf/cat/k8ak-ts_pt_n189-e1_3_7_csm1020919.pdf

PDF1 Single-phase Voltage Relay K8AK-VS
... voltage Isolated power supply 24 VAC/DC 100 to 240 VAC Power consumption 24 VAC/DC: 2.0 VA/1.1 W max. 100 to 240 VAC: 4.6 VA max. Operating value setting range (SV) 10% to 100% of maximum se...

https://www.ia.omron.com/data_pdf/cat/k8ak-vs_n181-e1_2_9_csm1020911.pdf

PDF1 Single-phase Overvoltage/Undervoltage Relay
... voltage Isolated power supply 24 VAC/DC 100 to 240 VAC Power consumption 24 VAC/DC: 2.0 VA/1.1 W max. 100 to 240 VAC: 4.6 VA max. Operating value setting range (AL1 and AL2) 10% to 100% of t...

https://www.ia.omron.com/data_pdf/cat/k8ak-vw_n182-e1_2_8_csm1020912.pdf

Results 4641 - 4650 of 4805