Primary Contents

Site Search Results

Site Search Product Search IA Global Search
Results 4611 - 4620 of 4795
PDF1 Magnetic Contactor J7KC Series
... consumption Making (VA) 22 (200 V) 25 (220 V) Holding (VA) 4.5 (200 V) 4.5 (220 V) Power loss (W) 1.2 (200 V) 1.3 (220 V) Must operate voltage (V) 122 to 135 128 to 138 Must release voltage ...

https://www.ia.omron.com/data_pdf/cat/j7kc_j230-e1_9_1_csm1074607.pdf

PDF1 Auxiliary Relay (Contactor Relay) J7KCA Series
... consumption Making (VA) 22 (200 V) 25 (220 V) Holding (VA) 4.5 (200 V) 4.5 (220 V) Power loss (W) 1.2 (200 V) 1.3 (220 V) Must operate voltage (V) 122 to 135 128 to 138 Must release voltage ...

https://www.ia.omron.com/data_pdf/cat/j7kca_j232-e1_6_1_csm1074609.pdf

PDF1 Manual Motor Starter (Motor Protection Circuit B...
... 13 (9-13) J7MC-3R-13 16 (11-16) J7MC-3R-16 20 (14-20) J7MC-3R-20 Model Auxiliary contact J73MC-W-10 SPST-1NO J73MC-W-01 SPST-1NC Model Auxiliary contact J73MC-K-10 SPST-1NO J73MC-K-...

https://www.ia.omron.com/data_pdf/cat/j7mc_j233-e1_5_1_csm1074610.pdf

PDFCSM_K2CM_DS_E_6_4 1 Motor Protective Relay K2CM
... power supply side of the Motor Protective Relay as shown in the above dia- grams. Ta Tc Tb U V W Output contacts (SPDT) Control power supply 200 VAC 50/60Hz RST Stop Start Phase advancing ca...

https://www.ia.omron.com/data_pdf/cat/k2cm_ds_e_6_4_csm373.pdf

PDF1 IO-Link AD Converter K3CV Analog signals are con...
... target Format Access Length Default value Range Remark 00 Direct Parameter Page 1 --- Record R/W 16 byte --- --- 20System-Command --- Uinteger W 1 byte - 0×81: Application Reset 0×8...

https://www.ia.omron.com/data_pdf/cat/k3cv_h243-e1_4_1_csm1132260.pdf

PDFCSM_K3GN_DS_E_7_2 1 1/32 DIN Digital Panel Meter K...
...IN Digital Panel Meter for Downsizing Equipment and Control Panels •Compact size: 48 x 24 x 82 (W x H x D). •Multi-input compatible: DC voltage/current, rotary pulse. •Two display colors (swi...

https://www.ia.omron.com/data_pdf/cat/k3gn_ds_e_7_2_csm253.pdf

PDFCSM_K3HB-C_DS_E_17_6 1 Up/Down Counting Pulse Indi...
...ltage Power consumption (See note 1.) 100 to 240 VAC: 18 VA max. (max. load) 24 VAC/DC: 11 VA/7 W max. (max. load) Input No-voltage contact, voltage pulse, open collector External power suppl...

https://www.ia.omron.com/data_pdf/cat/k3hb-c_ds_e_17_6_csm259.pdf

PDFCSM_K3HB-H_DS_E_14_7 1 Temperature Indicator K3HB-...
...voltage Power consumption (See note 1.) 100 to 240 V: 18 VA max. (max. load) 24 VAC/DC: 11 VA/7 W max. (max. load) Input Platinum-resistance thermometer: Pt100 Thermocouple: K, J, T, E, L, U,...

https://www.ia.omron.com/data_pdf/cat/k3hb-h_ds_e_14_7_csm260.pdf

PDFCSM_K3HB-P_DS_E_16_6 1 Timer Interval Indicator K3...
...ltage Power consumption (See note 1.) 100 to 240 VAC: 18 VA max. (max. load) 24 VAC/DC: 11 VA/7 W max. (max. load) Input No-voltage contact, voltage pulse, open collector External power suppl...

https://www.ia.omron.com/data_pdf/cat/k3hb-p_ds_e_16_6_csm261.pdf

PDFCSM_K3HB-R_DS_E_16_6 1 Rotary Pulse Indicator K3HB...
...ltage Power consumption (See note 1.) 100 to 240 VAC: 18 VA max. (max. load) 24 VAC/DC: 11 VA/7 W max. (max. load) Input No-voltage contact, voltage pulse, open collector External power suppl...

https://www.ia.omron.com/data_pdf/cat/k3hb-r_ds_e_16_6_csm262.pdf

Results 4611 - 4620 of 4795