XW5T-P DIN Track Push-in Terminal Blocks/Specifica...
... 2 to 4.0 mm 2 Dimensions 3.5 × 45 × 30.5 5.2 × 48.8 × 35.3 6.2 × 56.1 × 35.3 Rated voltage 500 V 800 V Rated current *3 17.5 A 24 A 32 A IEC rated voltage 500 V 800 ...

https://www.ia.omron.com/products/family/3480/specification.html

H3Y-[]-B Solid-state Timer/Specifications | OMRON ...
..., Ie: 2 A AC-13: Ue: 250 VAC, Ie: 3 A DC-13: Ue: 30 VDC, Ie: 0.5 A Rated insulation voltage 250 V Rated impulse withstand voltage (altitude: 2,000 m max.) 2.5 kV (at 240 VAC) Conditional shor...

https://www.ia.omron.com/products/family/3482/specification.html

H3YN-[]-B Solid-state Timer/Specifications | OMRON...
..., Ie: 2 A AC-13: Ue: 250 VAC, Ie: 3 A DC-13: Ue: 30 VDC, Ie: 0.5 A Rated insulation voltage 250 V Rated impulse withstand voltage (altitude: 2,000 m max.) 2.5 kV (at 240 VAC) Conditional shor...

https://www.ia.omron.com/products/family/3483/specification.html

S8VK-S S8VK-S (30/60/120/240/480-W Models)/Specifi...
...24 Ratings, Characteristics, and Functions Power rating 30 W 60 W 120 W Output voltagec (DC) 24 V 24 V 24 V Efficiency 115 VAC input *1 87% typ. 87% typ. 90% typ. 230 VAC in...

https://www.ia.omron.com/products/family/3485/specification.html

H3DT-G Star-delta Timer/Specifications | OMRON Ind...
...40 VAC: 1.9 VA max., at 240 VDC: 0.6 W max., at 24 VDC: 0.3 W max. Rated Insulation Voltage 250 V Control output Contact output: 5 A at 250 VAC with resistive load (cosφ = 1), 5 A at 30 VDC w...

https://www.ia.omron.com/products/family/3489/specification.html

K8DT-AS Single-phase Current Relay/Specifications ...
... capacity 10 A (per pole) Number of insertions 50 times Case color N1.5 Case material PC, UL 94 V-0 Weight Approx. 100 g Mounting Mounts to DIN Track, or screw mounting Dimensions 17.5 × 90 ×...

https://www.ia.omron.com/products/family/3491/specification.html

K8DT-AW Single-phase Overcurrent/Undercurrent Rela...
... capacity 10 A (per pole) Number of insertions 50 times Case color N1.5 Case material PC, UL 94 V-0 Weight Approx. 100 g Mounting Mounts to DIN Track, or screw mounting Dimensions 17.5 × 90 ×...

https://www.ia.omron.com/products/family/3492/specification.html

K8DT-VS Single-phase Voltage Relay/Specifications ...
...ange * Connection terminal Setting range Input impedance Overload capacity K8DT-VS2[][] 0 to 10 V AC/DC V1-COM 1 to 10 V AC/DC Approx. 120 kΩ Continuous input at 115% of maximum inpu...

https://www.ia.omron.com/products/family/3493/specification.html

K8DT-VW Single-phase Overvoltage/Undervoltage Rela...
...ange * Connection terminal Setting range Input impedance Overload capacity K8AK-VW2[][] 0 to 10 V AC/DC V1-COM 1 to 10 V AC/DC Approx. 120 kΩ Continuous input at 115% of maximum inpu...

https://www.ia.omron.com/products/family/3494/specification.html

K8DT-LS Conductive Level Controller/Specifications...
...S1[]D: 24 VAC 50/60 Hz, 24 VDC K8DT-LS1[]A: 100 to 240 VAC 50/60 Hz Voltage across electrodes 5 V p-p (Approx. 20 Hz) Power consumption 24 VAC/DC: 1.8 VA/1 W max. 100 to 240 VAC: 2.5 VA max. ...

https://www.ia.omron.com/products/family/3495/specification.html