Results 591 - 600 of 6516
ZN-A Air Clean Units/Specifications | OMRON Indust...
...F or on standby) Trouble Clogged filter (ZN-A6112P only) 30 VDC, 50 mA max. Residual voltage: 1 V max. with load current of 10 mA, 2 V max. with load current of 50 mA. Applicable Ion...

https://www.ia.omron.com/products/family/1828/specification.html

ZN-J Ionizers for Air Clean Unit/Specifications | ...
...DC discharge Static electricity removal time (Typical) *1 5 s max. Ion balance (Typical) *2 ±30 V max. Indicator lamps Power (green), Cleaning notice (orange flashing), Cleaning alarm (orange...

https://www.ia.omron.com/products/family/1829/specification.html

E2V-X[] All Metals and Long-distance Types/Specifi...
... Current consumption 450 mW max. (Current consumption: 15 mA max. at power supply voltage of 30 V) Control output Load current Open-collector output, 100 mA max. Residual voltage 2 V...

https://www.ia.omron.com/products/family/1937/specification.html

ZJ-FA20 Ionizer (Basic Fan Type)/Specifications | ...
....4 to 2.3 m 3 /min (typical) Ionization time *2 1.2 s (0.8 s with no Filter) Ion balance *2 ±10 V max. Amount of generated ozone 0.01 ppm max. (measured at a distance of 50 mm from air outlet...

https://www.ia.omron.com/products/family/1975/specification.html

E32-L11FP / L1[]FS, E3X-DA[][]TG-S Wet Process Sen...
...ntrol output Load power supply voltage: 26.4 VDC, load current: 50 mA max.; residual voltage: 1 V max. Response time Tough Mode (TG): Operate/reset in 16 ms each, Super Tough Mode (STG): Oper...

https://www.ia.omron.com/products/family/1985/specification.html

EE-SPX613 Pipe-mounting Liquid Level Photomicrosen...
...urrent: 100 mA max. OFF current: 0.5 mA max. 100 mA load current with a residual voltage of 0.8 V max. 40 mA load current with a residual voltage of 0.4 V max. Ambient illumination 3...

https://www.ia.omron.com/products/family/287/specification.html

A30NK Key-type Selector Switches/Specifications | ...
...Push-In Plus terminal block type) Ratings Contacts (Standard Load) Rated insulation voltage 600 V Rated carry current 10 A Rated voltage 24 V 120 V 240 V 380 ...

https://www.ia.omron.com/products/family/3449/specification.html

XW2Z-R Cables for I/O Relay Terminals/Specificatio...
...pecifications Dimensions Catalog last update: April 3, 2017 Rated current 1 A Rated voltage 250 V Contact resistance 20 mΩ max. (at 20 mV, 100 mA max.) * Insulation resistance 1,000 MΩ min. (...

https://www.ia.omron.com/products/family/3654/specification.html

E3S-CL Distance-settable Photoelectric Sensor with...
... power supply voltage: 30 VDC max., Load current: 100 mA max. Residual voltage: NPN output: 1.2 V max., PNP output: 2 V max. Open collector output (NPN/PNP depending on model) Light-...

https://www.ia.omron.com/products/family/415/specification.html

E3Z-LS Distance-settable Photoelectric Sensor/Spec...
... output Load power supply voltage: 26.4 VDC max., Load current: 100 mA max. (residual voltage 1 V max.), Open collector output (NPN or PNP depending on model) Light-ON/Dark-ON switch selectab...

https://www.ia.omron.com/products/family/420/specification.html