Results 591 - 600 of 5892
ZX-T Smart Sensors High-Precision Contact Type/Dim...
...X-TDS04T ZX-TDS04T-L * Measurement range: 14.9 to 18.9 (TYP) ZX-TDS10[] ZX-TDS10[]-L ZX-TDS10[]-V ZX-TDS10[]-VL Amplifier Unit ZX-TDA11 ZX-TDA41 Accessories (Order Separately) Preamplifier Mo...

https://www.ia.omron.com/products/family/1424/dimension.html

ZX-T Smart Sensors High-Precision Contact Type/Lin...
...a. Standard type 10 mm 0.4 μm ZX-TDS10T Ultra-low-load Type ZX-TDS10T-L Air Lift Type ZX-TDS10T-V Air Lift/Air Push Type ZX-TDS10T-VL Note: The resolution refers to the minimum value that can...

https://www.ia.omron.com/products/family/1424/lineup.html

EE-SA701 / 801 Pushbutton-type Photomicrosensor/Sp...
...Control output NPN Models: NPN open collector, 5 to 24 VDC, 50 mA max.; residual voltage of 0.4 V max. at 50-mA load current OFF current: 0.5 mA max. PNP Models: PNP open collector, 5 to 24 V...

https://www.ia.omron.com/products/family/1629/specification.html

ZJ-SD Smart Electrostatic Sensor/Specifications | ...
...ltage Standard mode: ±50 KV, Precision mode: ±5 KV max. *1 Display resolution Standard mode: 10 V, Precision mode: 1 V *2 Linearity *3 ±5% FS *4 Response time 20 ms Ambient temperatu...

https://www.ia.omron.com/products/family/1736/specification.html

ZN-A Air Clean Units/Specifications | OMRON Indust...
...F or on standby) Trouble Clogged filter (ZN-A6112P only) 30 VDC, 50 mA max. Residual voltage: 1 V max. with load current of 10 mA, 2 V max. with load current of 50 mA. Applicable Ion...

https://www.ia.omron.com/products/family/1828/specification.html

ZN-J Ionizers for Air Clean Unit/Specifications | ...
...DC discharge Static electricity removal time (Typical) *1 5 s max. Ion balance (Typical) *2 ±30 V max. Indicator lamps Power (green), Cleaning notice (orange flashing), Cleaning alarm (orange...

https://www.ia.omron.com/products/family/1829/specification.html

F3W-E Picking Sensor/Specifications | OMRON Indust...
...en collector output Load power supply: 30 VDC, Load current: 100 mA max. (Residual voltage: 1.8 V max.) Dark-ON or Light-ON (selectable) Picking instruction indicator input Relay or open coll...

https://www.ia.omron.com/products/family/1932/specification.html

E2V-X[] All Metals and Long-distance Types/Specifi...
... Current consumption 450 mW max. (Current consumption: 15 mA max. at power supply voltage of 30 V) Control output Load current Open-collector output, 100 mA max. Residual voltage 2 V...

https://www.ia.omron.com/products/family/1937/specification.html

ZJ-FA20 Ionizer (Basic Fan Type)/Specifications | ...
....4 to 2.3 m 3 /min (typical) Ionization time *2 1.2 s (0.8 s with no Filter) Ion balance *2 ±10 V max. Amount of generated ozone 0.01 ppm max. (measured at a distance of 50 mm from air outlet...

https://www.ia.omron.com/products/family/1975/specification.html

E32-L11FP / L1[]FS, E3X-DA[][]TG-S Wet Process Sen...
...ntrol output Load power supply voltage: 26.4 VDC, load current: 50 mA max.; residual voltage: 1 V max. Response time Tough Mode (TG): Operate/reset in 16 ms each, Super Tough Mode (STG): Oper...

https://www.ia.omron.com/products/family/1985/specification.html