Primary Contents

Site Search Results

Site Search Product Search IA Global Search
Results 6181 - 6190 of 6705
PDFCSM_E3C_DS_E_11_5 1 Compact Head Amplifier-separat...
...nute Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions Shock resistance Destruction: 500 m/s2 for 3 times each in X, Y...

https://www.ia.omron.com/data_pdf/cat/e3c_ds_e_11_5_csm418.pdf

PDF3 Servo Motor Selection Flow Chart
...llowing table Specialized Check Items Check Items Load Inertia Load Inertia≤Motor Rotor Inertia x Applicable Inertia Ratio Effective Torque Effective Torque ...

https://www.ia.omron.com/data_pdf/guide/14/servo_selection_tg_e_1_1_3-13(further_info).pdf

PDF5 SSR Glossary Glossary Note: This value was conve...
...nt of 220 A. The value of the protective resistance R is obtained from the following. R > 220 V x /200 A = 1.4Ω Considering the circuit current and ON time, insert the protective resistance i...

https://www.ia.omron.com/data_pdf/guide/18/ssr_tg_e_6_1_5_19-26(further_info).pdf

PDF13 Reference Material for Timers: Inrush Current
...ts B NC contacts LED Used to indicate the operating state of the Timer. or A B or A B AB SM A B X A B...

https://www.ia.omron.com/data_pdf/guide/19/timer_timeswitch_tg_e_3_1_13-14_4-6(further_info).pdf

PDF1 CSM_PLC Basic_TG_E_1_1 Technical Guide for PLC B...
...al Conversion Cable (CS1W-CIF31) *1.Applicable models: CS/CJ Series, C Series (C200HS, C200HE/G/X, C200H, C1000H, C2000H, CQM1, CPM1, CPM1A, CPM2A, CQM1H, and CPM2C), CVM1/CV Series, NS Serie...

https://www.ia.omron.com/data_pdf/guide/26/plc_tg_fi.pdf

PDFCSM_LevelAppatatus_TG_E_4_2 1 Technical Guide for ...
...ectrical circuit is open, and no current flows between electrodes E1 and E3. Consequently relay X does not operate and the contact remains at the b side. 2. When electrode E1 is in contact wi...

https://www.ia.omron.com/data_pdf/guide/33/levelappatatus_tg_e_4_2_1(overview).pdf

PDFCSM_LevelAppatatus_TG_E_4_2 1 Technical Guide for ...
...ectrical circuit is open, and no current flows between electrodes E1 and E3. Consequently relay X does not operate and the contact remains at the b side. 2. When electrode E1 is in contact wi...

https://www.ia.omron.com/data_pdf/guide/33/levelappatatus_tg_e_4_2_1-2(principles).pdf

PDF3 Level Controllers Glossary Purified Water
... into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. or or 1 2 X X...

https://www.ia.omron.com/data_pdf/guide/33/levelappatatus_tg_e_4_2_3-7_27-30(further_info).pdf

PDFRotary Encoders Technical Guide
...3 2 1 0 Ws:40N Ws:30N Ws: 20N Ws: 25N Wr Ws Shaft Encoder Wr: Radial load Ws: Thrust load Life (x 10 9 rotations) 28 24 20 16 12 8 4 0 1 2 5 10 20 50 100 200 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0 VOL...

https://www.ia.omron.com/data_pdf/guide/34/rotary_tg_e_6_1_p4-10(further_info).pdf

PDF23 General-purpose Relay Glossary
... is the back voltage. Bounce ON OFF ON Q 0 OFF 0 R Time Current Voltage Note 1: 2: Coil Current X NC contact waveform NO contact waveform Coil Voltage 26 Gluing Contacting surfaces cannot ope...

https://www.ia.omron.com/data_pdf/guide/36/generalrelay_tg_e_6_1_23-32_54-59_further_info.pdf

Results 6181 - 6190 of 6705