PDFContinuous remote monitoring of
...not require manual tasks. Reduced risk of equipment failure due to measurement with fixed DC 50 V Conventional measurement with a typical Megohmmeter requires selecting a voltage range in acc...

https://www.ia.omron.com/data_pdf/cat/k7ge_n226-e1_2_2_csm1107457.pdf

PDF1 Liquid Leakage Sensor Amplifiers K7L Series
...y insulated 3-conductor VCT cable with a thickness of 0.75 mm2 and a dielectric strength of 600 V is used together with a Liquid Sensing Band specified by OMRON. (A 0.2-mm2 cable can also be ...

https://www.ia.omron.com/data_pdf/cat/k7l_n211-e1_6_7_csm1050158.pdf

PDF1 Heater Condition Monitoring Device K7TM
...e K7TM Heater Condition Monitoring Device A Voltage and Current 2 2 channels MK7TM A 100 to 240 V AC power supply D 24 V AC/DC power supply Power supply voltage Model 100 to 240...

https://www.ia.omron.com/data_pdf/cat/k7tm_n228-e1_3_3_csm1115712.pdf

PDFMonitor Heater Condition with the K7TM
... New Area, Shanghai, 200120, China Tel: (86) 21-6023-0333 Fax: (86) 21-5037-2388 OMRON EUROPE B.V. Wegalaan 67-69, 2132 JD Hoofddorp The Netherlands Tel: (31) 2356-81-300 Fax: (31) 2356-81-38...

https://www.ia.omron.com/data_pdf/cat/k7tm_n229-e1_2_2_csm1118653.pdf

PDF1 Single-phase Current Relay K8AK-AS
...8GY (for AWG18) manufactured by Phoenix Contact Case color N1.5 Case material PC and ABS, UL 94 V-0 K8AK-AS 3 Specifications Weight Approx. 150 g Mounting Mounts to DIN Track Dimensions 22.5×...

https://www.ia.omron.com/data_pdf/cat/k8ak-as_n179-e1_4_7_csm1020909.pdf

PDF1 Single-phase Overcurrent/Undercurrent Relay
...8GY (for AWG18) manufactured by Phoenix Contact Case color N1.5 Case material PC and ABS, UL 94 V-0 Weight Approx. 150 g Mounting Mounts to DIN Track. Dimensions 22.5×90×100 mm (W×H×D) K8AK-A...

https://www.ia.omron.com/data_pdf/cat/k8ak-aw_n180-e1_4_8_csm1020910.pdf

PDF1 Conductive Level Controller K8AK-LS
...er supply voltage 24 VAC 50/60 Hz or 24 VDC 100 to 240 VAC 50/60 Hz Voltage across electrodes 5 V p-p (Approx. 20 Hz) Power consumption 24 VAC/DC: 2.0 VA/1.1 W max. 100 to 240 VAC: 4.6 VA max...

https://www.ia.omron.com/data_pdf/cat/k8ak-ls_n188-e1_4_9_csm1020918.pdf

PDF1 Three-phase Asymmetry and Phase-sequence Phase-l...
...220, 230, 240, 277 VAC SW3 ON OFF ON OFF SW4 ON ON OFF OFF K8AK-PA1 SW2 ONP-N138 V133 V127 V115 V OFF P-P 240V 230 V 220 V 200 V K8AK-PA2 SW2 ON P-N 277 V ...

https://www.ia.omron.com/data_pdf/cat/k8ak-pa_n186-e1_3_7_csm1020916.pdf

PDF1 Phase-sequence Phase-loss Relay
...8GY (for AWG18) manufactured by Phoenix Contact Case color N1.5 Case material PC and ABS, UL 94 V-0 Weight Approx. 130 g Mounting Mounts to DIN Track. Dimensions 22.5×90×100 mm (W×H×D) K8AK-P...

https://www.ia.omron.com/data_pdf/cat/k8ak-ph_n183-e1_3_6_csm1020913.pdf

PDF1 Three-phase Voltage and Phase-sequence Phase-los...
... 4-wire mode 220, 230, 240, 277 VAC SW3 ON OFF ON OFF SW4 ON ON OFF OFF K8AK-PM1 SW2 ON P-N 138 V 133 V 127 V 115 V OFF P-P 240V 230 V 220 V ...

https://www.ia.omron.com/data_pdf/cat/k8ak-pm_n185-e1_3_7_csm1020915.pdf