PDF1 Solid-state Timer H3CR Please read and understan...
... 30 VDC, Ie: 0.5 A Transistor Output: DC-13: Ue: 30 VDC, Ie: 0.1 A Rated insulation voltage 250 V Rated impulse withstand voltage (altitude: 2,000 m max.) 4 kV (at 240 VAC) Conditional short-...

https://www.ia.omron.com/data_pdf/cat/h3cr_l084-e1_3_6_csm1013792.pdf

PDF1 Solid-state Timers H3DK DIN Track-mounted, 22.5-...
..., Ie: 3 A AC-13: Ue: 250 VAC, Ie: 5 A DC-13: Ue: 30 VDC, Ie: 0.1 A Rated insulation voltage 250 V Rated impulse withstand voltage (altitude: 2,000 m max.) 4 kV (at 240 VAC) Conditional short-...

https://www.ia.omron.com/data_pdf/cat/h3dk_l118-e1_7_7_csm2645.pdf

PDFCSM_H3DS_DS_E_5_4 1 Solid-state Timer H3DS
...tart B1 Start Voltage Input Signal Levels No-contact input 1. Transistor ON Residual voltage: 1 V max. (Voltage between terminals B1 and A2 must be more than the rated "H-level" voltage (20.4...

https://www.ia.omron.com/data_pdf/cat/h3ds_ds_e_5_4_csm88.pdf

PDF1 Solid-state Timers H3DT DIN 17.5-mm-wide Slim Ti...
...er supply) Voltage Input Signal Levels Tran- sistor input 1. Transistor ON •Residual voltage: 1 V max. Voltage between terminals B1 and A2 must be equal to or higher than the rated high level...

https://www.ia.omron.com/data_pdf/cat/h3dt_m090-e1_4_8_csm1050135.pdf

PDFSolid-state Timers H3DT More Advanced Timers for N...
... New Area, Shanghai, 200120, China Tel: (86) 21-6023-0333 Fax: (86) 21-5037-2388 OMRON EUROPE B.V. Wegalaan 67-69, 2132 JD Hoofddorp The Netherlands Tel: (31) 2356-81-300 Fax: (31) 2356-81-38...

https://www.ia.omron.com/data_pdf/cat/h3dt_m091-e1_2_1_csm1050133.pdf

PDFCSM_H3FA_DS_E_8_3 1 Solid-state Timer H3FA
...ion, time-limit resetting/external resetting 4. Supply voltage For contact output models 5DC: 5 V DC 6DC: 6 V DC 12DC: 12 V DC 24DC: 24 V DC For solid-state output ...

https://www.ia.omron.com/data_pdf/cat/h3fa_ds_e_8_3_csm89.pdf

PDF1 Solid-state timer H3RN-@-B Compact, Multi-functi...
... New Area, Shanghai, 200120, China Tel: (86) 21-6023-0333 Fax: (86) 21-5037-2388 OMRON EUROPE B.V. Wegalaan 67-69, 2132 JD Hoofddorp The Netherlands Tel: (31) 2356-81-300 Fax: (31) 2356-81-38...

https://www.ia.omron.com/data_pdf/cat/h3rn-_-b_m093-e1_1_5_csm1050150.pdf

PDF1 Solid-state Timer H3Y Series Miniature Timer Com...
..., Ie: 2 A AC-13: Ue: 250 VAC, Ie: 3 A DC-13: Ue: 30 VDC, Ie: 0.5 A Rated insulation voltage 250 V Rated impulse withstand voltage (altitude: 2,000 m max.) 2.5 kV (at 240 VAC) Conditional shor...

https://www.ia.omron.com/data_pdf/cat/h3y_m092-e1_2_8_csm1050157.pdf

PDF1 Digital Timer H5CC New and improved design for e...
... a 2 The service life reduces to half when the temperature rises to 10°C. H5CC Input terminal 0 V terminal COM terminal -V +V DC stabilized power supply There is no sneak cu...

https://www.ia.omron.com/data_pdf/cat/h5cc_l220-e1_3_2_csm1124436.pdf

PDFCSM_H5F_DS_E_3_5 1 Digital Daily Time Switch H5F
...tact discharge (level 2) 8 kV air discharge (level 3) Immunity RF-interference: EN61000-4-3: 10 V/m (Amplitude-modulated, 80 MHz to 1 GHz, 1.4 to 2 GHz) (level 3) Immunity Conducted Disturban...

https://www.ia.omron.com/data_pdf/cat/h5f_ds_e_3_5_csm101.pdf

Results 6181 - 6190 of 6516