Site Search | Product Search | IA Global Search |
...A (24 VAC) Approx. 2.5 W (24 VDC) Sensor input Models with thermocouple inputs Thermocouple: K, J, T, R, or S (JIS C 1602-1995, IEC60584-1) Models with platinum resistance thermometer inputs ...
https://www.ia.omron.com/products/family/3024/specification.html
...d 4.1 VA max. at 24 VAC or 2.3 W max. at 24 VDC Sensor input Temperature input Thermocouple: K, J, T, E, L, U, N, R, S, B, C/W, or PL II Platinum resistance thermometer: Pt100 or JPt100 Infra...
https://www.ia.omron.com/products/family/3101/specification.html
...d 5.5 VA max. at 24 VAC or 3.2 W max. at 24 VDC Sensor input Temperature input Thermocouple: K, J, T, E, L, U, N, R, S, B, C/W, or PL II Platinum resistance thermometer: Pt100 or JPt100 Infra...
https://www.ia.omron.com/products/family/3102/specification.html
...ce thermometer if condensation is likely to result. Sheathed Thermocouples Element type K (CA), J(IC) Class JIS class 2 (0.75) Thermal contact Non-grounded type Sheath material CA: ASTM316L I...
https://www.ia.omron.com/products/family/3150/specification.html
...50°C to 250°C SUS304 E52-P6FY Low-cost thermocouple E52-CA[]ASY E52-IC[]ASY 0°C to 400°C K (CA) J (IC) Non- grounded type 2 (0.75) E52-CA1DY E52-IC1DY Grounded type E52-CA6F-N E52-CA6F-N-25 E...
...ost Thermocouples Exposed-lead Models with Spring E52-CA[]ASY, E52-IC[]ASY Element type K (CA), J (IC) Element dia. 0.65 mm (single wire) Class Class 2 (0.75) Protective tubing material SUS30...
https://www.ia.omron.com/products/family/3151/specification.html
...l Termi- nal type Bayonet spring for molding machines E52-CA2GVY E52-IC2GVY 0°C to 350°C K (CA) J (IC) Grounded type 2 (0.75) SUS304 Exposed lead wires Crimping terminals E52-CA1GTY E52-IC1GT...
...ls Thermocouples Thermocouples for Molding Machines E52-CA2GVY, E52-IC2GVY Element type K (CA), J (IC) Element diameter 1.0 mm (single wire) Class Class 2 (0.75) Protective tubing material SU...
https://www.ia.omron.com/products/family/3152/specification.html
...d 5.6 VA max. at 24 VAC or 3.4 W max. at 24 VDC Sensor input Temperature input Thermocouple: K, J, T, E, L, U, N, R, S, B, C/W, or PL II Platinum resistance thermometer: Pt100 or JPt100 Infra...
https://www.ia.omron.com/products/family/3157/specification.html
...ption 5 VA max. 2 W max. (24 VDC), 4 VA max. (24 VAC) Sensor inputs K8AK-TH11S Thermocouple: K, J, T, E; Platinum-resistance thermometer: Pt100, Pt1000 K8AK-TH12S Thermocouple: K, J,...
https://www.ia.omron.com/products/family/3241/specification.html
...d 2.8 VA max. at 24 VDC or 1.5 W max. at 24 VDC Sensor input Temperature input Thermocouple: K, J, T, E, L, U, N, R, S, B, C/W, or PL II Platinum resistance thermometer: Pt100 or JPt100 Infra...
https://www.ia.omron.com/products/family/3242/specification.html
...d 5.6 VA max. at 24 VAC or 3.4 W max. at 24 VDC Sensor input Temperature input Thermocouple: K, J, T, E, L, U, N, R, S, B, C/W, or PL II Platinum resistance thermometer: Pt100 or JPt100 Infra...
https://www.ia.omron.com/products/family/3287/specification.html
...d 4.1 VA max. at 24 VAC or 2.3 W max. at 24 VDC Sensor input Temperature input Thermocouple: K, J, T, E, L, U, N, R, S, B, C/W, or PL II Platinum resistance thermometer: Pt100 or JPt100 Infra...
https://www.ia.omron.com/products/family/3288/specification.html
...d 5.5 VA max. at 24 VAC or 3.2 W max. at 24 VDC Sensor input Temperature input Thermocouple: K, J, T, E, L, U, N, R, S, B, C/W, or PL II Platinum resistance thermometer: Pt100 or JPt100 Infra...
https://www.ia.omron.com/products/family/3289/specification.html
...d 3.2 VA max. at 24 VAC or 1.8 W max. at 24 VDC Sensor input Temperature input Thermocouple: K, J, T, E, L, U, N, R, S, B, C/W, or PL II Platinum resistance thermometer: Pt100 or JPt100 Infra...
https://www.ia.omron.com/products/family/3370/specification.html
...S-C200[][] (200 W) S8FS-C350[][] (350 W) Models with Terminal Block Facing Forward S8FS-C015[][]J (15 W) S8FS-C025[][]J (25 W) S8FS-C035[][]J (35 W) S8FS-C050[][]J ...
https://www.ia.omron.com/products/family/3460/dimension.html
...][] S82Y-FSC-C9 350-W S8FS-C350[][] Models with terminal block facing forward 15-W S8FS-C015[][]J/D S82Y-FSC-C5MF 25-W S8FS-C025[][]J/D S82Y-FSC-C5F 35-W S8FS-C035[][]J/D 50...
...o 240 VAC: 3.1 VA max. Rated insulation voltage 253 VAC Sensor inputs K8DT-TH1 Thermocouple: K, J, T, E; Platinum-resistance thermometer: Pt100, Pt1000 K8DT-TH2 Thermocouple: K, J, T...
https://www.ia.omron.com/products/family/3499/specification.html
... to the following table.) Consult your OMRON representative for details. Symbol A B C D E F G H J K L Q T U Stamp No designation SEC MIN H g kg mm cm m °C PCS x 10 SEC 0 ● last update: April ...
...d 4.1 VA max. at 24 VAC or 2.3 W max. at 24 VDC Sensor input Temperature input Thermocouple: K, J, T, E, L, U, N, R, S, B, C/W, or PL II Platinum resistance thermometer: Pt100 or JPt100 Infra...
https://www.ia.omron.com/products/family/3668/specification.html