Site Search | Product Search | IA Global Search |
...XW2K-COM XW2R (PLC連接型) XW2R(泛用連接型) XW2D XW2B (伺服用中繼模組) XW2B (運動控制模組) XW2Z XW2Z-L XW2Z-[][][]P-V / S-V / S-CV / T Top of page...
...Sensor Communications Unit Current consumption Normal mode: 80 mA max. (Power supply voltage 24 V) Eco ON: 70 mA max. (Power supply voltage 24 V) Eco LO: 75 mA max. (Power supply vol...
...t-in output Control output (Switching capacity) 200 mA max. Control output (Residual voltage) 2 V max. (Load current 200 mA with cable length of 2 m) Indicator Operation indicator (red) Opera...
...0.8 mA max. Control output (Switching capacity) 3 to 100 mA Control output (Residual voltage) 3 V max. (Load current 100 mA with cable length of 2 m) Indicator Operation indicator (red), Oper...
...mption 30 mA max. Control output NPN open collector 30 VDC max. 100 mA max. Residual voltage: 1 V max. Operation mode Light-ON/Dark-ON selectable Protective circuit Output short-circuit prote...
...0.8 mA max. Control output (Switching capacity) 3 to 100 mA Control output (Residual voltage) 3 V max. (Load current 100 mA max. with cable length of 2 m) Indicator Operation indicator (red),...
...mption 30 mA max. Control output NPN open collector 30 VDC max. 100 mA max. Residual voltage: 1 V max. Operation mode Light-ON/Dark-ON selectable Protective circuit Output short-circuit prote...
...t type) NPN Control output (Switching capacity) 200 mA max. Control output (Residual voltage) 2 V max. (Load current 200 mA with cable length of 2 m) Indicator Detection indicator (red) Opera...
...t type) NPN Control output (Switching capacity) 200 mA max. Control output (Residual voltage) 2 V max. (Load current 200 mA with cable length of 2 m) Indicator Operation indicator (red) Opera...
...t type) NPN Control output (Switching capacity) 200 mA max. Control output (Residual voltage) 2 V max. (Load current 200 mA with cable length of 2 m) Indicator Detection indicator (red) Opera...
...t type) NPN Control output (Switching capacity) 200 mA max. Control output (Residual voltage) 2 V max. (Load current 200 mA with cable length of 2 m) Indicator Operation indicator (red) Opera...
...t type) NPN Control output (Switching capacity) 200 mA max. Control output (Residual voltage) 2 V max. (Load current 200 mA with cable length of 2 m) Indicator Detection indicator (red) Opera...
...mption 30 mA max. Control output NPN open collector 30 VDC max. 100 mA max. Residual voltage: 1 V max. Operation mode Light-ON/Dark-ON selectable Protective circuit Output short-circuit prote...
...t type) NPN Control output (Switching capacity) 200 mA max. Control output (Residual voltage) 2 V max. (Load current 200 mA with cable length of 2 m) Indicator Operation indicator (red) Opera...
...mption 30 mA max. Control output NPN open collector 30 VDC max. 100 mA max. Residual voltage: 1 V max. Operation mode Light-ON/Dark-ON selectable Protective circuit Output short-circuit prote...
...umption 20 mA max. Control output NPN open collector 30 VDC max. 80 mA max. Residual voltage: 1 V max. Operation mode Light-ON Protective circuit Output short-cut protection, Power supply rev...
... 0.8 mA max. Control output (Switching capacity) 3 to 50 mA Control output (Residual voltage) 3 V max. (Load current 50 mA with cable length of 1 m) Indicator Operation indicator (orange) Ope...
...umption 20 mA max. Control output PNP open collector 30 VDC max. 80 mA max. Residual voltage: 1 V max. Operation mode Light-ON Protective circuit Output short-cut protection, Power supply rev...
...ceiver: 15 mA max. Control output NPN open collector 30 VDC max. 80 mA max. Residual voltage: 1 V max. Operation mode Dark-ON Protective circuit Output short-cut protection, Power supply reve...
...ceiver: 15 mA max. Control output PNP open collector 30 VDC max. 80 mA max. Residual voltage: 1 V max. Operation mode Dark-ON Protective circuit Output short-cut protection, Power supply reve...